Journal Article

Application of Dynamic Phasor Concept in Modeling Aircraft Electrical Power Systems

2013-09-17
2013-01-2083
As future commercial aircraft incorporates more EMAs, the aircraft electrical power system architecture will become a complex electrical distribution system with increased numbers of power electronic converters (PEC) and electrical loads. The overall system performance and the power management for on-board electrical loads are therefore key issues that need to be addressed. In order to understand these issues and identify high pay-off technologies that would enable a major improvement of the overall system performance, it is necessary to study the aircraft EPS at the system level. Due to the switching behaviour of power electronic devices, it is very time-consuming and even impractical to simulate a large-scale EPS with some non-linear and time-varying models. The dynamic phasor (DP) technique is one way to solve that problem.
Technical Paper

Application of Dynamic Phasors for Modeling of Active Front-End Converter for More-Electric Aircraft

2012-10-22
2012-01-2157
The paper deals with the development of active front-end rectifier model based on dynamic phasors concept. The model addresses the functional modeling level as defined by the multi-layer modeling paradigm and is suitable for accelerated simulation studies of the electric power systems under normal, unbalanced and line fault conditions. The performance and effectiveness of the developed model have been demonstrated by comparison against time-domain models in three-phase and synchronous space-vector representations. The experimental verification of the dynamic phasor model is also reported. The prime purpose of the model is for the simulation studies of more-electric aircraft power architectures at system level; however it can be directly applied for simulation study of any other electrical power system interfacing with active front-end rectifiers.
Technical Paper

Modeling of An 18-pulse Autotransformer Rectifier Unit with Dynamic Phasors

2012-10-22
2012-01-2159
The more-electric aircraft (MEA) is the major trend for airplanes in the next generation. Comparing with traditional airplanes, a significant increase of on-board electrical and electronic devices in MEAs has been recognized and resulted in new challenges for electrical power system (EPS) designers. The design of EPS essentially involves in extensive simulation work in order to ensure the availability, stability and performance of the EPS under all possible operation conditions. Due to the switching behavior of power electronic devices, it is very time-consuming and even impractical to simulate a large-scale EPS with some non-linear and time-varying models. The functional models in the dq0 frame have shown great performance under balanced conditions but these models become very time-consuming under unbalanced conditions, due to the second harmonics in d and q axes. The dynamic phasor (DP) technique has been proposed to solve that problem.
Technical Paper

Modulation Limit Based Control Strategy for More Electric Aircraft Generator System

2018-10-30
2018-01-1937
Vector based control strategies have been extensively employed for drive systems, and in recent times to the More Electric Aircraft (MEA) generator based systems. The control schemes should maintain the bus voltage and adhere to the generator system voltage and current limits throughout a wide speed range. Typically, the current limit is prioritised first due to ease of implementation and simple control structure. As a result, the voltage limit can be exceeded due to change in operating conditions or disturbance factors. In flux weakening regions, this may affect the controllability of the power converter and lead to generator system instability. In this paper, an alternative control strategy has been investigated to address this drawback. The proposed control scheme refers to the modulation index limit which is the ratio between the power converter input and output voltages as the voltage limit.
Technical Paper

Stability Study of DC Electric Power System with Paralleled Generators for More-Electric Aircraft

2014-09-16
2014-01-2114
Many More-Electric Aircraft (MEA) Electric Power System (EPS) architecture paradigms are being studied in order to provide the on-board electrical loads with high-quality supply and to ensure safe operation. EPS with dc distribution appears to be more promising due to higher efficiency, higher reliability, easier integration and lower overall weight. Another advantage of dc systems is the ease of sources paralleling, together with the optimization of load power sharing, this can lead to further EPS weight reduction. The DC bus can be fed by multiple sources such as generators, batteries and other energy storage devices. Many loads in MEA EPS are tightly controlled by power electronic converters and often behave as constant power loads (CPL). These are known as main contributors to the degradation of EPS stability margins. Therefore, stability study is one of the key topics in the assessment of potential EPS architecture candidates.
Technical Paper

Comparative Study of Power Sharing Strategies for the DC Electrical Power System in the MEA

2015-09-15
2015-01-2410
In this paper, the load sharing principles in dc-distribution electric power systems (EPS) for future more-electric aircraft (MEA) are investigated. The study is conducted using a potential MEA EPS architecture with multiple sources feeding into the main dc bus. Corresponding reduced-order EPS models are established. The influence of the cable impedance on the load sharing accuracy is analyzed and sharing error is quantized in mathematical equations. In addition, source/load impedance of the droop-controlled system has been derived leading to the discussion of the stability issues in multi-feed dc EPS under different droop control strategies. The influence of load sharing ratio on the EPS stability margins has been investigated. The theoretical findings were supported by time-domain simulations in Matlab/SimPower.
Technical Paper

Functional Modeling of 18-Pulse Autotransformer Rectifier Units for Aircraft Applications

2015-09-15
2015-01-2412
This paper aims to develop a general functional model of multi-pulse Auto-Transformer Rectifier Units (ATRUs) for More-Electric Aircraft (MEA) applications. The ATRU is seen as the most reliable way readily to be applied in the MEA. Interestingly, there is no model of ATRUs suitable for unbalanced or faulty conditions at the moment. This paper is aimed to fill this gap and develop functional models suitable for both balanced and unbalanced conditions. Using the fact that the DC voltage and current are strongly related to the voltage and current vectors at the AC terminals of ATRUs, a generic functional model has been developed for both symmetric and asymmetric ATRUs. The developed functional models are validated through simulation and experiment. The efficiency of the developed model is also demonstrated by comparing with corresponding detailed switching models. The developed functional model shows significant improvement of simulation efficiency, especially under balanced conditions.
Journal Article

Control Design for PMM-Based Generator Fed by Active Front-End Rectifier in More-Electric Aircraft

2016-09-20
2016-01-1987
The future aircraft electrical power system is expected to be more efficient, safer, simpler in servicing and easier in maintenance. As a result, many existing hydraulic and pneumatic power driven systems are being replaced by their electrical counterparts. This trend is known as a move towards the More-Electric Aircraft (MEA). As a result, a large number of new electrical loads have been introduced in order to power many primary functions including actuation, de-icing, cabin air-conditioning, and engine start. Therefore electric power generation systems have a key role in supporting this technological trend. Advances in modern power electronics allow the concept of starter/generator (S/G) which enables electrical engine start and power generation using the same electrical machine. This results in substantial improvements in power density and reduced overall weight.