Technical Paper

Factors Influencing Knee Restraint

1979-02-01
790322
A planar mathematical model was developed to provide means of studying factors which can influence the function of lower torso restraint via a padded lower instrument panel or knee bolster. The following factors were judged to play the most significant role: 1) initial fore-and-aft position of the seated occupant relative to the knee restraint; 2) location of the knee-to-bolster contact; 3) angular orientation of the bolster face; 4) primary axis of the bolster resisting force, 5) variations in vehicle crash parameters (e.g., toepan rotation and displacement and seat deflection); and 6) deformation characteristics of the bolster. The model of a seated occupant included radiographic and empirical data on the anatomy of the links and joints in the lower extremity.
Technical Paper

MVMA 2-D Modeling of Occupant Kinematics in Rollovers

1984-04-01
840860
This paper describes the mathematical modeling of occupant kinematics in rollover accidents using the MVMA 2-D occupant motion simulation software. What little information is available on the kinematics of vehicle occupants during rollover accidents has been obtained either after the fact by accident reconstruction or by expensive experimentally-staged events. The paper describes the use of less expensive analytical techniques to graphically illustrate the applicability of occupant motion simulation computer models to this problem.
Technical Paper

Considerations for a Femur Injury Criterion

1977-02-01
770925
A femur fracture injury criterion is presented that assesses the dependence of the permissible human knee load on the duration of the primary force exposure. Currently a constant allowable femur load limit of 7.6 kN (1700 lb) is specified in FMVSS 208, but recently the Federal Government proposed elevating the allowable limit to 10.0 kN (2250 lb), which is in excess of the limited experimental average static femur fracture force of 8.90 kN (2000 lb). A general analysis of all of the available biomechanics data and mathematical models on femoral impact response and fracture indicates a significant load time dependence for primary pulse durations below 20 ms that can elevate the permissible femur load above the Federally proposed allowable limit of 10.0 kN (2250 lb).
Technical Paper

Safety of a Downsized Vehicle Fleet: Effects of Mass Distribution, Impact Speed and Inherent Protection in Car-To-Car Crashes

1999-03-01
1999-01-0074
Vehicle fleet downsizing has been discussed in Europe as an aspect to reduce fuel emissions. A recently developed mathematical model was used to study the individual effects of fleet mass distribution, impact speed reductions and inherent vehicle protection on average injury and fatality rates for downsized fleets. A baseline fleet of 700-2000 kg was downsized by a) reducing all vehicle masses by 10% or 20% and b) by removing all cars heavier than 1400 or 1200 kg. The results showed that the safety can be maintained if the vehicle masses are reduced proportionally to their original mass. A higher safety level can be achieved by removing the heavier vehicles. Traffic safety can be further enhanced by impact speed reductions or by improvements of restraint systems and vehicle compatibility.