Refine Your Search

Topic

Affiliation

Search Results

Technical Paper

Water Quality Program Elements for Space Station Freedom

1991-07-01
911400
Space Station Freedom (SSF) will be operational for up to 30 years with missions lasting up to 180 days. Because of the need for large amounts of potable and hygiene water for the crews, it will not be practical to supply water from the ground (as was done for Skylab) or to generate water from fuel cells (as is done for the Shuttle). Hence, waste and metabolic waters will be reclaimed and recycled in SSF. Because of the unique nature of the water sources and the closed loop recycling processes, providing safe water will be a challenging task. Developing a program for the verification of SSF water quality to ensure crew health is the responsibility of NASA's Medical Sciences Division at the Johnson Space Center (JSC). This program is being implemented through the Environmental Health System (EHS). This paper will describe the strategy for the development of water quality criteria and standards, and the associated monitoring requirements.
Technical Paper

Sampling and Chemical Analysis of Potable Water for ISS Expeditions 12 and 13

2007-07-09
2007-01-3214
The crews of Expeditions 12 and 13 aboard the International Space Station (ISS) continued to rely on potable water from two different sources, regenerated humidity condensate and Russian ground-supplied water. The Space Shuttle launched twice during the 12-months spanning both expeditions and docked with the ISS for delivery of hardware and supplies. However, no Shuttle potable water was transferred to the station during either of these missions. The chemical quality of the ISS onboard potable water supplies was verified by performing ground analyses of archival water samples at the Johnson Space Center (JSC) Water and Food Analytical Laboratory (WAFAL). Since no Shuttle flights launched during Expedition 12 and there was restricted return volume on the Russian Soyuz vehicle, only one chemical archive potable water sample was collected with U.S. hardware and returned during Expedition 12. This sample was collected in March 2006 and returned on Soyuz 11.
Technical Paper

Colorimetric-Solid Phase Extraction Technology for Water Quality Monitoring: Evaluation of C-SPE and Debubbling Methods in Microgravity

2007-07-09
2007-01-3217
Colorimetric-solid phase extraction (C-SPE) is being developed as a method for in-flight monitoring of spacecraft water quality. C-SPE is based on measuring the change in the diffuse reflectance spectrum of indicator disks following exposure to a water sample. Previous microgravity testing has shown that air bubbles suspended in water samples can cause uncertainty in the volume of liquid passed through the disks, leading to errors in the determination of water quality parameter concentrations. We report here the results of a recent series of C-9 microgravity experiments designed to evaluate manual manipulation as a means to collect bubble-free water samples of specified volumes from water sample bags containing up to 47% air. The effectiveness of manual manipulation was verified by comparing the results from C-SPE analyses of silver(I) and iodine performed in-flight using samples collected and debubbled in microgravity to those performed on-ground using bubble-free samples.
Technical Paper

Water Recovery on the International Space Station: The Perspectives of Space Stations' Water Supply Systems

2007-07-09
2007-01-3174
The paper summarizes the six years' experience gained with the ISS water management system during the missions ISS-1 through ISS-14 (since November 2, 2000 through October 31, 2006). The water supply sources, consumption structure and supply balance and balance specifics at various phases of space station operation are reviewed. The performance data of the system for water recovery from humidity condensate SRV-K and urine feed and pretreatment system SPK-U in the Russian orbital segment are presented. The key role of water recovery during space missions and the prospects of regenerative water supply of an interplanetary space station are discussed. The aim of this paper is to summarize the water supply experience and to provide recommendations for a perspective water supply integrated system based on water recovery.
Technical Paper

Risk Mitigation Water Quality Monitor

1997-07-01
972463
On the International Space Station (ISS), atmospheric humidity condensate and other waste waters will be recycled and treated to produce potable water for use by the crews. Space station requirements include an on-orbit capability for real-time monitoring of key water quality parameters, such as total organic carbon, total inorganic carbon, total carbon, pH, and conductivity, to ensure that crew health is protected for consumption of reclaimed water. The Crew Health Care System for ISS includes a total organic carbon (TOC) analyzer that is currently being designed to meet this requirement. As part of the effort, a spacecraft TOC analyzer was developed to demonstrate the technology in microgravity and mitigate risks associated with its use on station. This analyzer was successfully tested on Shuttle during the STS-81 mission as a risk mitigation experiment. A total of six ground-prepared test samples and two Mir potable water samples were analyzed in flight during the 10-day mission.
Technical Paper

Electrochemically-Driven Micropump for Fluid Flow and Delivery: Toward a Novel Micropump Design for Miniaturized Liquid Chromatographic and Flow Injection Analyses

1997-07-01
972420
This paper describes the development of a prototype fluid pumping system for incorporation into a miniaturized flow injection analyzer. The strategy couples the well-established capabilities of reagent-based flow injection analyses (FIA) with our novel concepts for the design of a miniaturized, low-power pumping system, i.e., an electrochemically-driven micropump. The basis of pump actuation relies on the electrochemically-induced surface tension changes at the electrolyte/mercury interface, resulting in a “piston-like” pumping process devoid of mechanically moving parts. We present herein the results from the preliminary performance tests of a miniaturized fluid flow system with the micropump. As described, the flow rates and pumping displacement volumes have been studied as a function of the amplitude and the frequency of the applied voltage waveform.
Technical Paper

Testing and Operation of the Purification Unit of the System for Water Recovery from Humidity Condensate (WRS-C) with a Higher Content of Organic Contaminants

1998-07-13
981715
The paper presents the results of ground and flight (on OSS Mir) tests of an updated purification assembly of the WRS-C system outfitted with a filter-reactor. The tests have proved that the filter-reactor oxidizes effectively basic organic contaminants in humidity condensate including ethyleneglycol to ones that easily undergo sorption, enables the operation of the recovery system in the event of an off-design increase in organic contaminants in condensate and significantly improves the lifetime of the purification assembly. The data obtained confirm a wise selection of the purification assembly hardware for the system for water recovery from humidity condensate WRS-CM for the ISS service module.
Technical Paper

Humidity Condensate Sampling System for Shuttle, Mir and International Space Station

1998-07-13
981764
Archival sampling of potable water and condensate for ground laboratory analysis has been an important part of the Shuttle-Mir program because of coolant leaks and other events on Mir that have affected water quality. We report here the development of and preliminary results from a novel device for single phase humidity condensate collection at system pressures. The sampler consists of a commercial-off-the-shelf Teflon® bladder and a custom reinforced Nomex® restraint that is sized properly to absorb the stress of applied pressures. A plastic Luer-Lock disconnect, with poppet actuated by a mating Luer-Lock fitting, prevents the contents from being spilled during transport. In principle, a sampler of any volume can be designed. The empty mass of the reusable one-liter sampler is only 63 grams. Several designs were pressure tested and found to withstand more than 3 atmospheres well in excess of typical spacecraft water or wastewater system pressures.
Technical Paper

Total Organic Carbon Analyzer For ISS

1998-07-13
981765
On the International Space Station (ISS), atmospheric humidity condensate and other waste waters will be recycled and treated to produce potable water for use by the crews. Space Station requirements include an on-orbit capability for real-time monitoring of key water quality parameters, such as total organic carbon (TOC), total inorganic carbon (TIC), total carbon (TC), pH, and conductivity, to ensure that crew health is protected during consumption of reclaimed water. The Crew Health Care System (CHeCS) for ISS includes an analyzer that has been designed to meet this requirement. The analyzer is adapted from commercially successful technology, and it measures TOC and TIC throughout the range from 1 to 50,000 μg/L, and TC from 1 to 100,000 μg/L. It measures pH between 2.0 and 12.0 pH units, and conductivity from 0.1 to 300 μmho/cm. The analyzer is scheduled for launch to ISS on mission 2A.1.
Technical Paper

Colorimetric-Solid Phase Extraction (C-SPE): In-Flight Methodologies for the Facile Determination of Trace Level Indicators of Water Quality

2008-06-29
2008-01-2201
At present, spacecraft water quality is assessed when samples collected on the International Space Station (ISS) are returned to Earth. Several months, however, may pass between sample collection and analysis, potentially compromising sample integrity by risking degradation. For example, iodine and silver, which are the respective biocides used in the U.S. and Russian spacecraft potable water systems, must be held at levels that prevent bacterial growth, while avoiding adverse effects on crew health. A comparable need exists for the detection of many heavy metals, toxic organic compounds, and microorganisms. Lead, cadmium, and nickel have been found, for instance, in the ISS potable water system at amounts that surpass existent requirements. There have been similar occurrences with hazardous organic compounds like formaldehyde and ethylene glycol. Microorganism counts above acceptable limits have also been reported in a few instances.
Technical Paper

Archiving Trace Organic Contaminants in Spacecraft Water

2003-07-07
2003-01-2408
One of the long-standing concerns in space exploration is the presence of trace organic contaminants in recycled spacecraft water supplies. At present, water samples on the International Space Station (ISS) are collected at regular intervals, stored in Teflon™-lined containers, and returned to Earth for characterization. This approach, while effective in defining water quality, has several notable problems. First, this method of archiving removes a significant volume of the ISS water supply. Second, the archived water consumes valuable cargo space in returning Shuttle and Soyuz vehicles. Third, the organic contaminants present in the collected samples may degrade upon extended storage. The latter problem clearly compromises sample integrity. Upon return to Earth, sample degradation is minimized by refrigeration. Due to present resource constraints, however, refrigeration is not a viable option in space.
Technical Paper

Rapid Determination of Biocide Concentrations Using Colorimetric Solid Phase Extraction (C-SPE): Results from Microgravity Testing

2003-07-07
2003-01-2406
A sorption-spectrophotometric platform for the concentration and subsequent quantification of biocides in spacecraft drinking water is described. This methodology, termed Colorimetric Solid Phase Extraction (C-SPE), is based on the extraction of analytes onto a membrane impregnated with a colorimetric reagent. Quantification of the extracted analytes is accomplished by interrogating the surface of the membrane with a commercially available diffuse reflectance spectrophotometer. Ground-based experiments have shown that C-SPE is a viable means to determine biocide concentrations in the range commonly found in water samples from the Space Shuttle and the International Space Station (ISS). This paper details efforts to advance C-SPE closer to space flight qualification and ISS implementation, starting with the modification of the ground based biocide detection platform to simplify operation in a microgravity environment.
Technical Paper

ISS Total Organic Carbon Analyzer Status Update - 2003

2003-07-07
2003-01-2403
The Crew Health Care System (CHeCS) is responsible for providing environmental monitoring to protect crew health, including in-flight chemical water quality analysis. To meet this objective, Total Organic Carbon Analyzer (TOCA) Serial Number (SN) 1002 was launched to the International Space Station (ISS) in April of 2001 as part of the CHeCS hardware. Since that time it has been used to evaluate the quality of the potable water supplies consisting of reprocessed atmospheric condensate water, Shuttle-transferred water, and ground-supplied water. Potable water is available for crew use from the Service Module System for Regeneration of Water from Condensate (SRV-K) galley hot and warm ports and the Stored Potable Water System (SVO-ZV) port. Potable water samples are periodically collected from each of these ports for in-flight analysis with the TOCA.
Technical Paper

Water Recovery and Urine Collection Abord the International Space Station

2003-07-07
2003-01-2622
The paper deals with the performance data of the service module Zvezda water supply and urine collection systems of the International Space Station (ISS) as of December 31, 2002. The water supply and demand balance are analyzed. The data of humidity condensate and recovered water compositions are reviewed. The effective cooperation of the international partners on part of life support is shown.
Technical Paper

Water Recovery and Urine Collection in the Service Module of the International Space Station

2001-07-09
2001-01-2355
The paper deals with the construction and performance data of the service module Zvezda water supply system of the International Space Station (ISS). The performance data at an initial phase of manned station functioning are provided. The data on humidity condensate and recovered water composition are reviewed. The water supply and demand balance are analyzed. The effective cooperation of international partners on part of water supply for the crew is shown.
Technical Paper

ISS Total Organic Carbon Analyzer - 2002 Status

2002-07-15
2002-01-2533
Potable water supplies onboard the International Space Station (ISS) include both reclaimed water from treatment of atmospheric humidity condensate and stored water that is either Shuttle-transferred or ground-supplied. Space station medical operations requirements call for real-time monitoring of key water quality parameters, such as total organic carbon, total inorganic carbon, total carbon, pH, and conductivity, to ensure that crew health is protected from unsafe drinking water. A Total Organic Carbon Analyzer (TOCA) designed to meet these requirements was developed as part of the Crew Health Care System and launched to the ISS in April of 2001. The initial design of the ISS TOCA was previously presented at this conference in 1998. The current design of the instrument includes an improved reagent system and upgraded software to enhance accuracy through the capability to measure organic contamination of the reagents and correct analytical results.
Technical Paper

Water Recovery and Oxygen Generation by Electrolysis Aboard the International Space Station

2002-07-15
2002-01-2358
The paper deals with the construction and performance data of the service module Zvezda water and oxygen supply systems of the International Space Station (ISS). The performance data at the first 14 months of manned station functioning are provided. The data of humidity condensate and recovered water compositions are reviewed. The water supply and demand balance are analyzed. The system of oxygen generation “Electron-VM” and its functioning results are reviewed. The effective cooperation of the international partners on part of life support is shown.
Technical Paper

ISS Expeditions 10 & 11 Potable Water Sampling and Chemical Analysis Results

2006-07-17
2006-01-2015
During the twelve month period comprising Expeditions 10 and 11, the chemical quality of the potable water onboard the International Space Station (ISS) was verified through the return and ground analysis of water samples. The two-man Expedition 10 crew relied solely on Russian-provided ground water and reclaimed cabin humidity condensate as their sources of potable water. Collection of archival water samples with U.S. hardware has remained extremely restricted since the Columbia tragedy because of very limited return volume on Russian Soyuz vehicles. As a result only two such samples were collected during Expedition 10 and returned on Soyuz 9. The average return sample volume was only 250 milliliters, which limited the breadth of chemical analysis that could be performed. Despite the Space Shuttle vehicle returning to flight in July 2005, only two potable water samples were collected with U.S. hardware during Expedition 11 and returned on Shuttle flight STS-114 (LF1).
Technical Paper

The Performance of the System for Water Recovery from Humidity Condensate (SRV-K) on International Space Station, ISS Missions 1 through 11

2006-07-17
2006-01-2269
The paper summarizes the experience gained with the ISS water management system during the missions ISS-1 through ISS-11 (since November 2 2000, through October 10, 2005). The water supply sources and structure, consumption and supply balance at various phases of space station operation are reviewed. The performance data of the system for water recovery from humidity condensate SRV-K and urine feed and pretreatment system SPK-U in the Russian orbital segment are presented. The key role of water recovery on board the ISS and the need to supplement the station’s water supply hardware with a system for water reclamation from urine SRV-U is shown. The prospects of regenerative water supply system development are considered.
Technical Paper

Further Characterization and Multifiltration Treatment of Shuttle Humidity Condensate

1995-07-01
951685
On the International Space Station (ISS), humidity condensate will be collected from the atmosphere and treated by multifiltration to produce potable water for use by the crews. Ground-based development tests have demonstrated that multifiltration beds filled with a series of ion-exchange resins and activated carbons can remove many inorganic and organic contaminants effectively from wastewaters. As a precursor to the use of this technology on the ISS, a demonstration of multifiltration treatment under microgravity conditions was undertaken. On the Space Shuttle, humidity condensate from cabin air is recovered in the atmosphere revitalization system, then stored and periodically vented to space vacuum. A Shuttle Condensate Adsorption Device (SCAD) containing sorbent materials similar to those planned for use on the ISS was developed and flown on STS-68 as a continuation of DSO 317, which was flown initially on STS-45 and STS-47.
X