This SAE Information Report provides: a Types of valve guides and their nomenclature b Valve guide alloy designations and their chemistries c Valve guide alloy metallurgy d Typical mechanical and physical properties of guide alloys e Typical dimensional tolerances of valve guides and their counterbores f Recommended interference fits g Installation procedures h Application considerations
This SAE Information Report provides: a Types of valve guides and their nomenclature b Valve guide alloy designations and their chemistries c Valve guide alloy metallurgy d Typical mechanical and physical properties of guide alloys e Typical dimensional tolerances of valve guides and their counterbores f Recommended interference fits g Installation procedures h Application considerations
The scope of this SAE Information Report is to provide general information relative to the nature and use of magnetic particles for nondestructive testing. The document is not intended to provide detailed technical information, but will serve as an introduction to the theory and capabilities of magnetic particle testing, and as a guide to more extensive references.
The scope of this SAE Information Report is to provide general information relative to the nature and use of magnetic particles for nondestructive testing. The document is not intended to provide detailed technical information, but will serve as an introduction to the theory and capabilities of magnetic particle testing, and as a guide to more extensive references.
The purpose of this SAE Information Report is to provide basic information on penetrating radiation, as applied in the field of nondestructive testing, and to supply the user with sufficient information so that he may decide whether penetrating radiation methods apply to his particular inspection need. Detailed information references are listed in Section 2.
The purpose of this SAE Information Report is to provide basic information on penetrating radiation, as applied in the field of nondestructive testing, and to supply the user with sufficient information so that he may decide whether penetrating radiation methods apply to his particular inspection need. Detailed information references are listed in Section 2.
This SAE Recommended Practice covers the mechanical and chemical requirements of oil-tempered chromium-vanadium valve spring quality wire used for the manufacture of engine valve springs and other springs used at moderately elevated temperatures and requiring high fatigue properties. It also covers the processing requirements of spring fabricated from this wire.
This SAE Recommended Practice covers the mechanical and chemical requirements of oil-tempered chromium-vanadium valve spring quality wire used for the manufacture of engine valve springs and other springs used at moderately elevated temperatures and requiring high fatigue properties. It also covers the processing requirements of spring fabricated from this wire.
This SAE Recommended Practice covers the physical and chemical requirements of oil- tempered carbon-steel valve spring quality wire used for the manufacture of engine valve springs and other springs requiring high-fatigue properties. This document also covers the processing requirements of springs fabricated from this wire.
This SAE Recommended Practice covers the physical and chemical requirements of oil-tempered carbon-steel valve spring quality wire used for the manufacture of engine valve springs and other springs requiring high-fatigue properties. This document also covers the basic processing requirements of springs fabricated from this wire.
This standard describes a test method for evaluating the susceptibility of uncoated cold rolled and hot rolled Ultra High Strength Steels (UHSS) to hydrogen embrittlement. The thickness range of materials that can be evaluated is limited by the ability to bend and strain the material to the specified stress level in this specification. Hydrogen embrittlement can occur with any steel with a tensile strength greater than or equal to 980 MPa. Some steel microstructures, especially those with retained austenite, may be susceptible at lower tensile strengths under certain conditions. The presence of available hydrogen, combined with high stress levels in a part manufactured from high strength steel, are necessary precursors for hydrogen embrittlement. Due to the specific conditions that need to be present for hydrogen embrittlement to occur, cracking in this test does not indicate that parts made from that material would crack in an automotive environment.
This SAE Information Report provides a summary of several methods that are available for detecting, and in some instances detecting and measuring, surface imperfections in rods, bars, tubes, and wires. References relating to detailed technical information and to specific applications are enumerated in 2.2.
This SAE Recommended Practice defines the set-up and procedure for conducting the SAE Single Tooth Bending Fatigue Test. The details of the test fixture to be used (referred henceforth as “the test fixture” in this document) and gear test sample and the procedures for testing and analyzing the data are presented in this document.
This SAE Recommended Practice defines the set-up and procedure for conducting the SAE Single Tooth Bending Fatigue Test. The details of the test fixture to be used (referred henceforth as “the test fixture” in this document) and gear test sample and the procedures for testing and analyzing the data are presented in this document.