This specification covers established metric manufacturing tolerances applicable to aluminum alloy drawn tubing ordered to metric dimensions. These tolerances apply to all conditions, unless otherwise noted. The term "excl" applies only to the higher figure of the specified range.
This specification covers established metric manufacturing tolerances applicable to aluminum alloy drawn tubing ordered to metric dimensions. These tolerances apply to all conditions, unless otherwise noted. The term "excl" applies only to the higher figure of the specified range.
This specification describes the general connectors, contacts, and backshells in their shape and characteristic for cabin systems for commercial aircrafts. ARINC 600, ARINC 404, and ARINC 801 connector specifications are published as independent standards.
This specification describes the general connectors, contacts, and backshells in their shape and characteristic for cabin systems for commercial aircrafts. ARINC 600, ARINC 404, and ARINC 801 connector specifications are published as independent standards.
The Manufacturing Message Specification is an application layer Standard designed to support messaging communications to and from programmable devices in a Computer Integrated Manufacturing (CIM) environment. This environment is referred to in this Standard as the manufacturing environment. This Standard does not specify a complete set of services for remote programming of devices, although provision of such a set of services may be the subject of future standardization efforts.
This document defines a secure Wi-Fi distribution network installed in the aircraft passenger cabin for passenger and crew use. Carry-on Portable Electronic Devices (PEDs) such as smart phones, tablets, and laptops may use this network to access public internet services provided on the aircraft.
This SAE Aerospace Information Report (AIR) describes procedures, required continuous sampling conditions, and instrumentation for the measurement of non-volatile particle number and mass concentrations from the exhaust of aircraft gas turbine engines. Procedures are included to calculate sampling loss performance. This AIR is not intended for in-flight testing, nor does it apply to engine operating in the afterburning mode.
This report defines the requirements and recommended practices for production testing of aircraft passenger seats and seat groups. Production testing is performed at the seat manufacturers' facilities prior to the shipment of the seats to the airframe manufacturers, Maintenance, Repair, and Overhaul (MRO), or airlines/operators for installation in the aircraft. Using this guidance, rework is minimized and schedules remain minimally affected.
ARINC 661 defines logical interfaces to Cockpit Display Systems (CDS) used in all types of aircraft installations. The CDS provides graphical and interactive services to user applications within the flight deck environment. When combined with data from user applications, it displays graphical images to the flight deck crew. The document emphasizes the need for independence between aircraft systems and the CDS. This document defines the interface between the avionics equipment and display system graphics generators. This document does not specify the "look and feel" of any graphical information, and as such does not address human factors issues. These are defined by the airline flight operations community. Supplement 7 adds the definition of: Selector Widget, Tree Widget, New FormatString options, Readouts available in MapItems, Provisions for Touch Screen Displays.
This document establishes the minimum criteria for effective training of air carrier and contractor personnel to deice/anti-ice aircraft to ensure the safe operation of aircraft during ground icing conditions. Appendix D specifies guidelines for particular airplane models.
• Define sub-roles within the primary J3016 roles • Define different human capabilities and list what those are (including definition of “capability”) • Frame issues • Document open questions
This SAE Recommended Practice applies to both Original Equipment Manufacturer (OEM) and aftermarket message-generating systems for light and heavy vehicles. The recommended practice covers both message prioritization and presentation (including simultaneous display of messages) for visual and auditory modalities. In addition, this recommended practice will consider temporal aspects of external events (e.g. merging into heavy traffic, time-to-collision) and their impact on temporal presentation and format (including multi-modal) of messages.
This SAE Standard applies to equipment to be used to recovery R-152a refrigerant only. Refrigerant recovery equipment is required to ensure adequate refrigerant recovery to reduce emissions and provide safe and accurate service of the AC system. Equipment shall be certified to meet all performance requirements outlined in this document.
This document describes the megawatt-level DC charging system requirements for couplers/inlets, cables, cooling, communication and interoperability. The intended application is for commercial vehicles with larger battery packs requiring higher charging rates for moderate dwell time. A simplified analog safety signaling approach is used for connection-detection to guarantee de-energized state for unmated couplers with superimposed high speed data for EVSE-EV charging control and other value added services.
This SAE standard applies to refrigerant identification equipment to be used for identifying an acceptable level of R-152a purity in a refrigerant tank or vehicle MAC system labeled as containing R-152a, and not misidentify other refrigerants.
This SAE Standard applies to equipment to be used with R-152a refrigerant only. It establishes requirements for equipment used to recharge R-152a to an industry accepted accuracy level and purity levels defined in SAE J2099. Refrigerant service equipment is required to ensure adequate refrigerant recovery to reduce emissions and provide for accurate recharging of mobile air conditioning systems. Equipment shall be certified to meet all performance requirements outlined in this document and international/regional construction and safety requirements as outlined in this document.
This SAE Standard provides testing and functional requirements to meet specified minimum performance criteria for electronic probe-type leak detectors suitable for use with R-152a, an A2 flammable refrigerant. The equipment specified here will identify smaller refrigerant leaks when servicing motor vehicle air conditioning systems, including those engineered with improved sealing and smaller refrigerant charges to address environmental concerns and increase system efficiency.