Refine Your Search

Topic

Author

Search Results

Standard

TOLERANCES, METRIC Aluminum Alloy Drawn Tubing

1994-04-01
MAM2203A
This specification covers established metric manufacturing tolerances applicable to aluminum alloy drawn tubing ordered to metric dimensions. These tolerances apply to all conditions, unless otherwise noted. The term "excl" applies only to the higher figure of the specified range.
Standard

TOLERANCES, METRIC Aluminum Alloy Drawn Tubing

2002-07-23
MAM2203
This specification covers established metric manufacturing tolerances applicable to aluminum alloy drawn tubing ordered to metric dimensions. These tolerances apply to all conditions, unless otherwise noted. The term "excl" applies only to the higher figure of the specified range.
Standard

Manufacturing Message Specification – Service Definition and Protocol

2016-06-28
CURRENT
EIA511
The Manufacturing Message Specification is an application layer Standard designed to support messaging communications to and from programmable devices in a Computer Integrated Manufacturing (CIM) environment. This environment is referred to in this Standard as the manufacturing environment. This Standard does not specify a complete set of services for remote programming of devices, although provision of such a set of services may be the subject of future standardization efforts.
Standard

CABIN ARCHITECTURE FOR WIRELESS DISTRIBUTION SYSTEM

2019-08-13
CURRENT
ARINC820
This document defines a secure Wi-Fi distribution network installed in the aircraft passenger cabin for passenger and crew use. Carry-on Portable Electronic Devices (PEDs) such as smart phones, tablets, and laptops may use this network to access public internet services provided on the aircraft.
Standard

Procedure for the Continuous Sampling and Measurement of Non-Volatile Particle Emissions from Aircraft Turbine Engines

2013-11-18
HISTORICAL
AIR6241
This SAE Aerospace Information Report (AIR) describes procedures, required continuous sampling conditions, and instrumentation for the measurement of non-volatile particle number and mass concentrations from the exhaust of aircraft gas turbine engines. Procedures are included to calculate sampling loss performance. This AIR is not intended for in-flight testing, nor does it apply to engine operating in the afterburning mode.
Standard

CABIN PASSENGER SEAT PRODUCTION TESTING

2019-12-18
CURRENT
ARINC648
This report defines the requirements and recommended practices for production testing of aircraft passenger seats and seat groups. Production testing is performed at the seat manufacturers' facilities prior to the shipment of the seats to the airframe manufacturers, Maintenance, Repair, and Overhaul (MRO), or airlines/operators for installation in the aircraft. Using this guidance, rework is minimized and schedules remain minimally affected.
Standard

COCKPIT DISPLAY SYSTEM INTERFACES TO USER SYSTEMS PART 1 AVIONICS INTERFACES, BASIC SYMBOLOGY, AND BEHAVIOR

2019-06-17
CURRENT
ARINC661P1-7
ARINC 661 defines logical interfaces to Cockpit Display Systems (CDS) used in all types of aircraft installations. The CDS provides graphical and interactive services to user applications within the flight deck environment. When combined with data from user applications, it displays graphical images to the flight deck crew. The document emphasizes the need for independence between aircraft systems and the CDS. This document defines the interface between the avionics equipment and display system graphics generators. This document does not specify the "look and feel" of any graphical information, and as such does not address human factors issues. These are defined by the airline flight operations community. Supplement 7 adds the definition of: Selector Widget, Tree Widget, New FormatString options, Readouts available in MapItems, Provisions for Touch Screen Displays.
Standard

Training Program Guidelines for Deicing/Anti-Icing of Aircraft on Ground

2014-08-05
HISTORICAL
ARP5149BDA
This document establishes the minimum criteria for effective training of air carrier and contractor personnel to deice/anti-ice aircraft to ensure the safe operation of aircraft during ground icing conditions. Appendix D specifies guidelines for particular airplane models.
Standard

Driver Vehicle Interface (DVI) Message Priority and Presentation

2018-11-05
WIP
J3189
This SAE Recommended Practice applies to both Original Equipment Manufacturer (OEM) and aftermarket message-generating systems for light and heavy vehicles. The recommended practice covers both message prioritization and presentation (including simultaneous display of messages) for visual and auditory modalities. In addition, this recommended practice will consider temporal aspects of external events (e.g. merging into heavy traffic, time-to-collision) and their impact on temporal presentation and format (including multi-modal) of messages.
Standard

Megawatt Charging System for Electric Vehicles

2021-12-15
WIP
J3271
This document describes the megawatt-level DC charging system requirements for couplers/inlets, cables, cooling, communication and interoperability. The intended application is for commercial vehicles with larger battery packs requiring higher charging rates for moderate dwell time. A simplified analog safety signaling approach is used for connection-detection to guarantee de-energized state for unmated couplers with superimposed high speed data for EVSE-EV charging control and other value added services.
Standard

R-152a Recovery/Recycling/Recharging Equipment for Flammable Refrigerants for Mobile Air-Conditioning Systems

2019-12-10
WIP
J3222
This SAE Standard applies to equipment to be used with R-152a refrigerant only. It establishes requirements for equipment used to recharge R-152a to an industry accepted accuracy level and purity levels defined in SAE J2099. Refrigerant service equipment is required to ensure adequate refrigerant recovery to reduce emissions and provide for accurate recharging of mobile air conditioning systems. Equipment shall be certified to meet all performance requirements outlined in this document and international/regional construction and safety requirements as outlined in this document.
Standard

R-152a Refrigerant Electronic Leak Detectors, Minimum Performance Criteria

2019-12-10
WIP
J3221
This SAE Standard provides testing and functional requirements to meet specified minimum performance criteria for electronic probe-type leak detectors suitable for use with R-152a, an A2 flammable refrigerant. The equipment specified here will identify smaller refrigerant leaks when servicing motor vehicle air conditioning systems, including those engineered with improved sealing and smaller refrigerant charges to address environmental concerns and increase system efficiency.
X