Refine Your Search

Topic

Search Results

Standard

Auxiliary Power Unit Electrical Interface Requirements for Class Eight Trucks

2020-04-29
CURRENT
J2891_202004
This SAE Recommended Practice covers the design and application of a 120 VAC single phase engine based auxiliary power unit or GENSET. This document is intended to provide design direction for the single phase nominal 120 VAC as it interfaces within the truck 12 VDC battery and electrical architecture providing power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off.
Standard

Auxiliary Power Unit Electrical Interface Requirements for Class Eight Trucks

2010-07-06
HISTORICAL
J2891_201007
This SAE Recommended Practice covers the design and application of a 120 VAC single phase engine based auxiliary power unit or GENSET. This document is intended to provide design direction for the single phase nominal 120 VAC as it interfaces within the truck architecture providing power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off.
Standard

Auxiliary Power Unit Electrical Interface Requirements for Class Eight Trucks

2015-12-18
HISTORICAL
J2891_201512
This SAE Recommended Practice covers the design and application of a 120 VAC single phase engine based auxiliary power unit or GENSET. This document is intended to provide design direction for the single phase nominal 120 VAC as it interfaces within the truck architecture providing power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off.
Standard

15 Pole Connector Between Towing Vehicles and Trailers with 12 Volt Nominal Supply

2020-02-25
CURRENT
J2691_202002
This SAE Standard establishes the minimum construction and performance requirements for a 15 pole connector between towing vehicles and trailers, for trucks, trailers, and dollies, for 12 VDC nominal applications in conjunction with SAE J2742. The connector accommodates both power and ISO 11992-1 signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design—Truck and Bus

2022-06-22
CURRENT
J2698_202206
This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids.
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design—Truck and Bus

2008-01-14
HISTORICAL
J2698_200801
This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids.
Standard

COILED ELECTRICAL CABLE

1993-11-01
HISTORICAL
J2222_199311
This Draft Technical Report covers the minimum performance and endurance requirements for coiled electrical cables to connect a tractor and trailer and/or trailer to trailer. The purpose of this Draft Technical Report is to give the technical community the opportunity to review, comment on, and use the Draft Technical Report prior to its final approval by SAE. This document shall have a life span of no more than three years from approval which may not be renewed. This Draft Technical Report represents the current thinking of the sponsoring Technical Committee. The use of this report is entirely voluntary, and its applicability and suitability for any particular use, including any patent infringements arising therefrom, is the sole responsibility of the user. Comments on this Draft are welcome and should be submitted in writing to Secretary, Technical Standards Board, SAE Headquarters, 400 Commonwealth Drive, Warrendale, PA 15096-0001.
Standard

Seven Conductor Cable - Truck and Bus

2012-08-14
HISTORICAL
J1067_201208
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-1/10-5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Seven Conductor Cable—Truck and Bus

2007-06-12
HISTORICAL
J1067_200706
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-1/10-5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Seven Conductor Cable - Truck and Bus

2016-10-25
HISTORICAL
J1067_201610
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-1/10-5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Recommended Practice for Identification of Standardized Truck and Tractor Electrical Circuits

2019-01-08
HISTORICAL
J2191_201901
This SAE document defines a recommended practice for implementing circuit identification for electrical power and signal distribution systems of the Class 8 trucks and tractors. This document provides a description of a supplemental circuit identifier that shall be utilized in conjunction with the original equipment manufacturer’s primary circuit identification as used in wire harnesses but does not include electrical or electronic devices which have pigtails. The supplemental circuit identifier is cross-referenced to a specified subsystem of the power and signal distribution system identified in Section 5.
Standard

Recommended Practice for Identification of Standardized Truck and Tractor Electrical Circuits

2014-02-21
HISTORICAL
J2191_201402
This SAE document defines a recommended practice for implementing circuit identification for electrical power and signal distribution systems of the Class 8 trucks and tractors. This document provides a description of a supplemental circuit identifier that shall be utilized in conjunction with the original equipment manufacturer’s primary circuit identification as used in wire harnesses but does not include electrical or electronic devices which have pigtails. The supplemental circuit identifier is cross-referenced to a specified subsystem of the power and signal distribution system identified in Section 5.
Standard

Recommended Practice for Identification of Standardized Truck and Tractor Electrical Circuits

2004-01-30
HISTORICAL
J2191_200401
This SAE Recommended Practice defines a recommended practice for implementing circuit identification for the circuits of the power and signal distribution systems of the Class 8 trucks and tractors. This document provides a description of a supplemental circuit identifier that shall be utilized in conjunction with the original equipment manufacturer’s primary circuit identification as used in wire harnesses but does not include electrical or electronic devices which have pigtails. The supplemental circuit identifier is cross-referenced to a specified subsystem of the power and signal distribution system identified in Section 5.
Standard

Recommended Practice for Identification of Standardized Truck and Tractor Electrical Circuits

2010-01-07
HISTORICAL
J2191_201001
This SAE document defines a recommended practice for implementing circuit identification for electrical power and signal distribution systems of the Class 8 trucks and tractors. This document provides a description of a supplemental circuit identifier that shall be utilized in conjunction with the original equipment manufacturer’s primary circuit identification as used in wire harnesses but does not include electrical or electronic devices which have pigtails. The supplemental circuit identifier is cross-referenced to a specified subsystem of the power and signal distribution system identified in Section 5.
Standard

RECOMMENDED PRACTICE FOR IDENTIFICATION OF STANDARDIZED TRUCK AND TRACTOR ELECTRICAL CIRCUITS

1997-02-01
HISTORICAL
J2191_199702
This SAE Recommended Practice defines a recommended practice for implementing circuit identification for the circuits of the power and signal distribution systems of the Class 8 trucks and tractors. This document provides a description of a supplemental circuit identifier that shall be utilized in conjunction with the original equipment manufacturer’s primary circuit identification as used in wire harnesses but does not include electrical or electronic devices which have pigtails. The supplemental circuit identifier is cross-referenced to a specified subsystem of the power and signal distribution system identified in Section 5.
Standard

Recommended Practice for Identification of Standardized Truck and Tractor Electrical Circuits

2002-12-13
HISTORICAL
J2191_200212
This SAE Recommended Practice defines a recommended practice for implementing circuit identification for the circuits of the power and signal distribution systems of the Class 8 trucks and tractors. This document provides a description of a supplemental circuit identifier that shall be utilized in conjunction with the original equipment manufacturer’s primary circuit identification as used in wire harnesses but does not include electrical or electronic devices which have pigtails. The supplemental circuit identifier is cross-referenced to a specified subsystem of the power and signal distribution system identified in Section 5.
Standard

Truck Tractor Power Output for Trailer ABS

2013-09-05
HISTORICAL
J2247_201309
This SAE Recommended Practice identifies the minimum truck tractor electrical power output of the stop lamp and ABS (antilock brake system) circuits measured at the primary SAE J560 tractor trailer interface connector(s).
Standard

Truck Tractor Power Outlet for Trailer ABS

2019-12-17
HISTORICAL
J2247_201912
This SAE Recommended Practice identifies the minimum truck tractor electrical power output of the stop lamp and ABS (antilock brake system) circuits measured at the primary SAE J560 tractor trailer interface connector(s).
Standard

Seven Conductor Cable for ABS Power—Truck and Bus

2007-06-22
HISTORICAL
J2394_200706
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-2/10-4/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications. While the document’s title refers to ABS Power to differentiate the document from the SAE J1067 standard that it supersedes, the scope applies to both the primary green cable for powering ABS and lighting and the yellow auxiliary cable of the same construction.