Standard

Recommended Best Practice for Climatic Wind Tunnel Correlation

2007-01-08
HISTORICAL
J2777_200701
With many corporations and suppliers conducting development and validation tests at different Climatic Wind Tunnel sites, there is an increasing need for a recommended best practice that defines a process by which climatic wind tunnels can be correlated. This document addresses the test methods and metrics used to obtain similar results, independent of location, for Heating Ventilation and Air Conditioning (HVAC) and Powertrain Cooling (PTC) development. This document should be used as a guideline to make sure key aspects of tunnel testing are covered when comparing various climatic wind tunnel facilities. The depth of the correlation program is ultimately influenced by program objectives. Therefore a correlation program, for the intent and purposes of this document, can range from just a few tests to a full analysis that involves multiple vehicle tests identifying limitations and statistical boundaries.
Standard

Recommended Best Practice for Climatic Wind Tunnel Correlation

2022-11-14
CURRENT
J2777_202211
With many corporations and suppliers conducting development and validation tests at different climatic wind tunnel sites, there is an increasing need for a recommended best practice that defines a process by which climatic wind tunnels can be correlated. This document addresses the test methods and metrics used to correlate results from different facilities, independent of location, for heating ventilation and air conditioning (HVAC) and powertrain cooling (PTC) development. This document should be used as a guideline to make sure key aspects of tunnel testing are covered when comparing various climatic wind tunnel facilities. The depth of the correlation program is ultimately influenced by program objectives; therefore, a correlation program, for the intent and purposes of this document, can range from just a few tests to a full analysis that involves multiple vehicle tests identifying limitations and statistical boundaries.
Standard

Recommended Best Practice for Climatic Wind Tunnel Correlation

2016-01-14
HISTORICAL
J2777_201601
With many corporations and suppliers conducting development and validation tests at different Climatic Wind Tunnel sites, there is an increasing need for a recommended best practice that defines a process by which climatic wind tunnels can be correlated. This document addresses the test methods and metrics used to obtain similar results, independent of location, for Heating Ventilation and Air Conditioning (HVAC) and Powertrain Cooling (PTC) development. This document should be used as a guideline to make sure key aspects of tunnel testing are covered when comparing various climatic wind tunnel facilities. The depth of the correlation program is ultimately influenced by program objectives. Therefore a correlation program, for the intent and purposes of this document, can range from just a few tests to a full analysis that involves multiple vehicle tests identifying limitations and statistical boundaries.
Standard

Passenger Car Backlight Defogging System

2011-05-26
CURRENT
J953_201105
The scope of this SAE Recommended Practice is to establish uniform test procedures for passenger cars, to determine whether the system is defined as a defroster or defogger, and to establish minimum performance requirements for each system. A defroster for purposes of this practice is a system which will remove moisture and/or frost from the interior surface of the backlight at −18 °C. A defogger is a system which will remove moisture and/or fog from the interior surface of the backlight at 4 °C. The test procedure is intended to simulate actual conditions by utilizing either a cold room with an appropriate device to introduce air flow over the backlight or a sufficiently large wind tunnel with ambient temperature control. The test procedure and the minimum performance requirements are based on currently available engineering data.