Refine Your Search

Search Results

Viewing 1 to 7 of 7
Technical Paper

Testbed for Determining the Filtering Capacities of COTS Adsorbents

2007-07-09
2007-01-3137
A lab-scale testbed for screening and characterizing the chemical specificity of commercial “off-the-shelf” (COTS) polymer adsorbents was built and tested. COTS polymer adsorbents are suitable candidates for future trace contaminant (TC) control technologies. Regenerable adsorbents could reduce overall TC control system mass and volume by minimizing the amounts of consumables to be resupplied and stored. However, the chemical specificity of these COTS adsorbents for non-methane volatile organic compounds (NMVOCs) (e.g., methanol, ethanol, dichloromethane, acetone, etc) commonly found in spacecraft is unknown. Furthermore, the effect of humidity on their filtering capacity is not well characterized. The testbed, composed of a humidifier, an incubator, and a gas generator, delivers NMVOC gas streams to conditioned sorbent tubes.
Technical Paper

Performance of Salad-Type Plants Using Lighting and Nutrient Delivery Concepts Intended for Spaceflight

1998-07-13
981554
Because of mass and power constraints in spacecraft, plant growth units designed for spaceflight have limited volume and low photosynthetic photon flux (PPF). Sufficient lighting and nutrient delivery are basic challenges to the success of supporting long-term plant growth in space. At the Kennedy Space Center, plant lighting and nutrient delivery hardware currently under NASA-sponsored development are being evaluated to define some of the fundamental issues associated with producing different fresh salad crops. Lettuce crops performed well under all nutrient delivery systems and lighting sources tested. Spinach and radish yields were lower in the presence of zeoponic media (using an ASTROCULTURE™ root tray) relative to plant grown in conventional NFT systems. Within each nutrient delivery system, yields of salad crops under red LEDs + blue light were similar to those crops grown under conventional white light.
Technical Paper

Ultraviolet Light Emitting Diodes for Disinfection of Spacecraft Potable Water Systems

2009-07-12
2009-01-2508
This report describes proof-of-concept testing of a commercial-off-the-shelf deep ultraviolet LED for future application as a point-of-use or residual disinfection device for spacecraft potable water systems. The electro-optical performance and disinfection efficacy of a 0.5 mW 265nm UV-C LED (UVTOP, Sensor Electronic Technology, Inc., Columbia, SC) was measured in both static and flow environments against five challenge microorganisms inoculated into potable water at an initial concentration ≥ 108 cells per milliliter. The germicidal irradiation from a single UV-C LED array was sufficient to effect > 4-log kill (> 99.99%) of the challenge bacterial population in < 60 minutes contact time.
Technical Paper

Bacterial and Fungal Communities in BPS Chambers and Root Modules

2003-07-07
2003-01-2528
The PESTO (Photosynthetic Experiment System Testing and Operation) experiment flew in the Biomass Production System (BPS) to International Space Station (ISS) on STS-110 (Atlantis) April 8, 2002, and returned on STS-111 (Endeavour) June 19, 2002, after 73 days in space. The ground control was conducted on a two-week delay at Kennedy Space Center in a BPS unit under environmental conditions comparable to ISS. Wheat (Triticum aestivum cv Apogee) and Brassica rapa cv Astroplant were independently grown in root modules for multiple grow-outs. On-orbit harvests, root modules exchanges and primings, seeds imbibitions, and gas and water samplings occurred at periodic intervals; all were replicated in ground controls. Many operations required crew handling and open access to individual chambers, allowing the exchange of microorganisms between the crew environment and the BPS modules.
Technical Paper

Feed-Back Moisture Sensor Control for the Delivery of Water to Plants Cultivated in Space

2005-07-11
2005-01-2952
The development of a spaceflight-rated Porous Tube Insert Module (PTIM) nutrient delivery tray has facilitated a series of studies evaluating various aspects of water and nutrient delivery to plants as they would be cultivated in space. We report here on our first experiment using the PTIM with a software-driven feedback moisture sensor control strategy for maintaining root zone wetness level set-points. One-day-old wheat seedlings (Tritium aestivum cv Apogee; N=15) were inserted into each of three Substrate Compartments (SCs) pre-packed with 0.25–1 mm Profile™ substrate and maintained at root zone relative water content levels of 70, 80 and 90%. The SCs contained a bottom-situated porous tube around which a capillary mat was wrapped. Three Porous Tubes were planted using similar protocols (but without the substrate) and also maintained at these three moisture level set-points. Half-strength modified Hoagland’s nutrient solution was used to supply water and nutrients.
Technical Paper

Design of a UV-A LED Photocatalytic Oxidation Reactor for Testing Spacecraft Potable Water Disinfection Technologies

2009-07-12
2009-01-2509
This report describes the design, assembly, and testing of a modified, re-circulating drip flow reactor to quantify the electrical, optical, and thermal performance of solid-state ultraviolet (UV) lighting and semi-conducting photocatalyst for potable water disinfection by advanced oxidation processes. The reactor test assembly incorporates high-output UV-A Light Emitting Diodes (LEDs) with active thermal control to reject heat and generate reactive oxygen species from immobilized titanium dioxide attached to borosilicate glass in the laminar flow stream. Compared with UV-excimer and UV-mercury arc lamps, the UV-A LED system demonstrated excellent thermal stability and good electrical and optical performance.
Technical Paper

Long-Term Storage of Wheat Plants for Light Microscopy

2000-07-10
2000-01-2231
The objectives of these experiments were two fold: 1) to determine if accepted tissue fixation procedures can be adapted for long-term storage on-board the International Space Station (ISS) and 2) to test whether they are suitable for KSC Fixation Tubes (KFTs). Three tissue fixation parameters were tested: time, temperature and sample size.Fixation time:samples are normally fixed from several minutes to several hours, but because of the duration of the UF-1 mission to ISS, the tissue will be in fixative for up to 3 months. Super dwarf wheat tissue samples were fixed in either FAA (a fixative normally used for storage of plant tissues) or a glutaraldehyde-based fixative and stored for 100 days.