Technical Paper

Capillary Limit in a Loop Heat Pipe with a Single Evaporator

2002-07-15
2002-01-2502
This paper describes a study on the capillary limit of a loop heat pipe (LHP) at low powers. The slow thermal response of the loop at low powers makes it possible to observe interactions among various components after the capillary limit is exceeded. The capillary limit at low powers is achieved by imposing an additional pressure drop on the vapor line through the use of a metering valve. A differential pressure transducer is also used to measure the pressure drop across the evaporator and the compensation chamber (CC). Test results show that when the capillary limit is exceeded, vapor will penetrate the primary wick, resulting in an increase of the CC temperature. Because the evaporator can tolerate vapor bubbles, the LHP will continue to function and may reach a new steady state at a higher operating temperature. Thus, the LHP will exhibit a graceful degradation in performance rather than a complete failure.
Technical Paper

Capillary Limit in a Loop Heat Pipe with Dual Evaporators

2002-07-15
2002-01-2503
This paper describes a study on the capillary limit of a loop heat pipe (LHP) with two evaporators and two condensers. Both theoretical analysis and experimental investigation are performed. Experimental tests conducted include heat load to one evaporator only, even heat loads to both evaporators, and uneven heat loads to both evaporators. Test results show that after the capillary limit is exceeded, vapor will penetrate through the wick of the weaker evaporator, and the compensation chamber (CC) of that evaporator will control the loop operating temperature regardless of which CC has been in control prior to the event. Because the evaporator can tolerate vapor bubbles, the loop can continue to work after vapor penetration. As the loop operating temperature increases, the system pressure drop actually decreases due to a decrease in liquid and vapor viscosities. Thus, the loop may reach a new steady state at a higher operating temperature after vapor penetration.
Technical Paper

Testing of Flight Components for the Capillary Pumped Loop Flight Experiment

1993-07-01
932235
The Capillary Pumped Loop Flight Experiment (CAPL) is a prototype of the Earth Observing System (EOS) instrument thermal control systems. Four CAPL flight hardware components were tested in the Instrument Thermal Test Bed at NASA's Goddard Space Flight Center. The components tested were the capillary cold plates, capillary starter pump, heat pipe heat exchangers (HPHXs), and reservoir. The testing verified that all components meet or exceed their individual performance specifications. Consequently, the components have been integrated into the CAPL experiment which will be flown on the Space Shuttle in late 1993.
Technical Paper

Flow Visualization within a Capillary Evaporator

1993-07-01
932236
A Capillary Pumped Loop (CPL) is an advanced two-phase heat transport device which utilizes capillary forces developed within porous wicks to move a working fluid. The advantage this system has over conventional thermal management systems is its ability to transfer large heat loads over long distances at a controlled temperature. Extensive ground testing and two flight experiments have been performed over the past decade which have demonstrated the potential of the CPL as a reliable and versatile thermal control system for space applications. While the performance of CPL's as “black boxes” is now well understood, the internal thermo-fluid dynamics in a CPL are poorly known due to the difficulty of taking internal measurements. In order to visualize transient thermohydraulic processes occurring inside an evaporator, a see-through capillary evaporator was built and tested at NASA's Goddard Space Flight Center.
Technical Paper

Flight Testing of a Cryogenic Capillary Pumped Loop

1999-08-02
1999-01-2627
This paper describes the flight test results of the fifth generation cryogenic capillary pumped loop (CCPL-5) which flew on the Space Shuttle STS-95 in October of 1998 as part of the CRYOTSU Flight Experiment. This flight was the first in-space demonstration of the CCPL, a lightweight heat transport and thermal switching device for future integrated cryogenic bus systems. The CCPL-5 utilized nitrogen as the working fluid and operated between 75K and 110K. Flight results indicated excellent performance of the CCPL-5 in a micro-gravity environment. The CCPL could start from a supercritical condition in all tests, and the reservoir set point temperature controlled the loop operating temperature regardless of changes in the heat load and/or the sink temperature. In addition, the loop demonstrated successful operation with heat loads ranging from 0.5W to 3W, as well as with parasitic heat loads alone.