This SAE Information Report defines the test methods and specifications for the electrostatic discharge sensitivity of passenger cars, multipurpose passenger vehicles, trucks and buses.
This SAE Standard covers the measurement of Impulse Electric Field Strength radiated over the frequency range of 20–1000 MHz from a vehicle or other device powered by an internal combustion engine or electric motor. Operation of all engines (main and auxiliary) on a vehicle or other device is included. All equipment normally operating when the engine is running is also included, except operator-controlled equipment, which is excluded. The recommended limit applies only to complete vehicles or devices in their final manufactured form. Vehicle mounted rectifiers used for battery charging in electric vehicles are included in this specification when operated in their charging mode.
This standard covers the measurement of impulsive electromagnetic radiation over the frequency range of 20–1000 MHz from a vehicle or other device powered by an internal combustion engine or electric motor. Operation of all engines (main and auxiliary) on a vehicle or other device is included. All equipment normally operating when the engine is running is also included, except operator-controlled equipment, which is excluded. The recommended limit applies only to complete vehicles or devices in their final manufactured form. Vehicle mounted rectifiers used for battery charging in electric vehicles are included in this specification when operated in their charging mode.
This standard covers the measurement of impulsive electromagnetic radiation over the frequency range of 20 to 1(100 MHz from a motor vehicle or other device powered by an internal combustion engine. Operation of all engines (main and auxiliary) on a vehicle or other device is included. All equipment normally operating when the engine is running is also included, except operator-controlled equipment, which is excluded. The recommended limit applies only to complete vehicles or devices in their final manufactured form.
This SAE Standard specifies the ESD test methods and procedures necessary to evaluate electronic modules intended for vehicle use. It describes test procedures for evaluating electronic modules in complete vehicles. A procedure for verifying the simulator that is used to generate the electrostatic discharges is given in Appendix A. Functional status classifications for immunity to ESD are given in Appendix B.
This SAE Standard specifies the ESD test methods and procedures necessary to evaluate electronic modules intended for vehicle use. It describes test procedures for evaluating electronic modules in complete vehicles. A procedure for verifying the simulator that is used to generate the electrostatic discharges is given in Appendix A. Functional status classifications for immunity to ESD are given in Appendix B.
The process described in this document is generally applicable to provide a means to classify the function performance status of automotive electronic devices. Testing of devices could be performed either on or off vehicles. Appropriate test pulse and methods, functional status classification, region of performance, and test pulse severity level would have to be specified in the individual cases.
This SAE Recommended Practice provides a general method for defining the function performance status classification for the functions of automotive electronic devices upon application of the test conditions specified as described in appropriate EMC test standards (for example, the SAE J1113 series and the SAE J551 series). Testing of devices could be performed either on or off vehicles. Appropriate test signal and methods, region of performance, and test signal severity level would have to be specified in the individual cases.
This SAE Standard provides a general method for defining the acceptable function performance status classification for the functions of automotive electronic devices upon application of the test conditions specified as described in appropriate EMC immunity test standards (for example, SAE J1113 and SAE J551). Testing of devices could be performed either on or off vehicles. Appropriate test signal and methods, Function Performance status, and test signal severity level would have to be specified in the individual cases.
This SAE Standard provides a general method for defining the function performance status classification for the functions of automotive electronic devices upon application of the test conditions specified as described in appropriate EMC test standards (for example, the SAE J1113 series and the SAE J551 series). Testing of devices could be performed either on or off vehicles. Appropriate test signal and methods, region of performance, and test signal severity level would have to be specified in the individual cases.
This SAE Standard provides a general method for defining the function performance status classification for the functions of automotive electronic devices upon application of the test conditions specified as described in appropriate EMC test standards (for example, SAE J1113 & SAE J551). Testing of devices could be performed either on or off vehicles. Appropriate test signal and methods, Function Performance status, and test signal severity level would have to be specified in the individual cases.
This SAE Standard provides a general method for defining the acceptable function performance status classification for the functions of automotive electronic devices upon application of the test conditions specified as described in appropriate EMC immunity test standards (for example, SAE J1113 and SAE J551). Testing of devices could be performed either on or off vehicles. Appropriate test signal and methods, Function Performance status, and test signal severity level would have to be specified in the individual cases.
This SAE Standard establishes a common basis for the evaluation of devices and equipment in vehicles against transient transmission by coupling via lines other than the power supply lines. The test demonstrates the immunity of the instrument, device, or equipment to coupled fast transient disturbances, such as those caused by switching of inductive loads, relay contact bouncing, etc. Two test methods are presented - Coupling Clamp and Chattering Relay.
This SAE Standard establishes test methods for the evaluation of devices and equipment in vehicles against transient transmission by coupling via lines other than the power supply lines. The test methods demonstrates the immunity of the instrument, device, or equipment to coupled fast transient disturbances, such as those caused by switching of inductive loads, relay contact bouncing, etc. Four test methods are presented in SAE J1113-12: the capacitive coupling clamp (CCC) method the direct capacitive coupling (DCC) method the inductive coupling clamp (ICC) method the capacitive/inductive coupling (CIC) method
This measurement procedure defines a method for measuring the electromagnetic radiation from an integrated circuit (IC). The IC being evaluated is mounted on an IC test printed circuit board (PCB) that is clamped to a mating port (referred to as a wall port) cut in the top or bottom of a TEM or wideband TEM (GTEM) cell. The test board is not in the cell as in the conventional usage but becomes a part of the cell wall. This method is applicable to any TEM or GTEM cell modified to incorporate the wall port; however, the measured RF voltage is affected by the septum to test board (wall) spacing. This procedure was developed using a 1 GHz TEM cell with a septum to wall spacing of 45 mm and a GTEM cell with average septum to wall spacing of 45 mm over the port area. Other cells may not produce identical spectral output but may be used for comparative measurements, subject to their frequency and sensitivity limitations.
This measurement procedure defines a method for measuring the electromagnetic radiation from an integrated circuit (IC). The IC being evaluated is mounted on an IC test printed circuit board (PCB) that is clamped to a mating port (referred to as a wall port) cut in the top or bottom of a TEM or wideband TEM (GTEM) cell. The test board is not in the cell as in the conventional usage but becomes a part of the cell wall. This method is applicable to any TEM or GTEM cell modified to incorporate the wall port; however, the measured RF voltage is affected by the septum to test board (wall) spacing. This procedure was developed using a 1 GHz TEM cell with a septum to wall spacing of 45 mm and a GTEM cell with average septum to wall spacing of 45 mm over the port area. Other cells may not produce identical spectral output but may be used for comparative measurements, subject to their frequency and sensitivity limitations.
This SAE Standard specifies the test methods and procedures necessary to evaluate electrical components intended for automotive use to the threat of Electrostatic Discharges (ESDs). It describes test procedures for evaluating electrical components on the bench in the powered mode and for the packaging and handling non-powered mode. A procedure for calibrating the simulator that is used for electrostatic discharges is given in Appendix A. An example of how to calculate the RC Time Constant is given in Appendix B Functional Performance Status Classifications for immunity to ESD and Sensitivity classifications for ESD sensitive devices are given in Appendix C.
This SAE Standard specifies the test methods and procedures necessary to evaluate electrical components intended for automotive use to the threat of Electrostatic Discharges (ESDs). It describes test procedures for evaluating electrical components on the bench in the powered mode and for the packaging and handling non-powered mode. A procedure for calibrating the simulator that is used for electrostatic discharges is given in Appendix A. An example of how to calculate the RC Time Constant is given in Appendix B Functional Performance Status Classifications for immunity to ESD and Sensitivity classifications for ESD sensitive devices are given in Appendix C.