Refine Your Search

Topic

Search Results

Viewing 1 to 16 of 16
Standard

Ergonomic Guidelines for Carts and Dollies

2015-03-13
CURRENT
USCAR41
This document describes the assessment methods and physical requirements associated with the manual handling of carts and dollies, specific to material handling systems. All possible designs and applications could not be anticipated in creating these guidelines. Where there are questions of adherence to this document, such as use of an “off-the shelf” design, always consult the responsible Ergonomics Department. Force guidelines were primarily developed referencing the push/pull psychophysical Snook data contained in A Guide to Manual Materials Handling (second edition) by Mital, Nicholson and Ayoub (NY: Taylor & Francis, 1997). The force guidelines accommodate 75% of female capabilities and 99% of male capabilities. Factors that were included in the established guideline include: push / pull distances, vertical hand height, horizontal hand height, frequency and wheel / castor alignment and load rating. These factors were used to develop a conservative force guideline.
Standard

Ergonomic Guidelines for Small Lot Delivery Operations

2015-03-10
CURRENT
USCAR42
This document describes the design, assessment methods and physical requirements associated with material handling systems. This would include, but not limited to manual dollies, small lot systems and kitting. All possible designs and applications could not be anticipated in creating these guidelines. Where there are questions of adherence to this document, such as use of an “off-the shelf” design, always consult the responsible Ergonomics Department.
Standard

STANDARD FOR CIGAR LIGHTERS & POWER OUTLETS

1998-09-01
HISTORICAL
USCAR4
This standard is intended to cover cigar or cigarette lighters as well as power outlets based on the form and dimensions of the cigar lighter. This standard is a full performance specification, it includes dimensional and operational parameters as well as performance characteristics which must be met when submitting a cigar lighter assembly or power outlet assembly for production approval. This standard constitutes an acceptance specification for a surface mounted, front-loaded cigar lighter or power outlet.
Standard

Standard for Cigar Lighters & Power Outlets

2014-03-31
CURRENT
USCAR4-1
This standard is intended to cover cigar or cigarette lighters as well as power outlets based on the form and dimensions of the cigar lighter. This standard is a full performance specification, it includes dimensional and operational parameters as well as performance characteristics which must be met when submitting a cigar lighter assembly or power outlet assembly for production approval. This standard constitutes an acceptance specification for a surface mounted, front-loaded cigar lighter or power outlet.
Standard

STANDARD FOR IN-TANK ELECTRIC FUEL PUMPS

1999-08-15
HISTORICAL
USCAR13
This standard covers the operational characteristics, environment, durability procedures, and test procedures for in-tank electric fuel pumps for automotive gasoline applications. Specific performance and test criteria used in conjunction with this procedure are specified on the pump drawing. Particular sections of this document may be required for all applications. This standard is intended to evaluate specific characteristics as a supplement to normal material inspections, dimensional checking, and in-process controls, and should in no way adversely influence other inspection operations.
Standard

Specification for Testing Automotive Halogen Light Sources

2006-01-01
HISTORICAL
USCAR14-2
The procedures contained in this specification cover the laboratory testing of replaceable halogen incandescent bulbs for use in automotive road illumination. The following tests are intended to be run under the following conditions. New bulb design Design or process change made to an existing bulb, which could affect the outcome of the test The completion of one calendar year, accept as noted in the following Test Schedule Table. Test Title Yearly Physical Dimensions X Mean Spherical Candela (MSCD) X External Visual Examination X Color X Leak/Sealability Through Terminals and Seals X Deflection X Fluid Compatibility Terminal Retention X Resonant Frequencies Aged Resonant Frequency Salt Spray Outgassing Temperatures Requirement Laboratory Life at 14.0 VDC X Luminous Intensity Maintenance X Vibration Durability Shock Aged Vibration Durability Terminal Requirements DRL (SAE J2087)
Standard

SPECIFICATION FOR TESTING AUTOMOTIVE HALOGEN LIGHT SOURCES

2022-03-15
CURRENT
USCAR14-3
The procedures contained in this specification cover the laboratory testing of replaceable halogen incandescent bulbs for use in automotive road illumination. The following tests are intended to be run under the following conditions. New bulb design Design or process change made to an existing bulb, which could affect the outcome of the test The completion of one calendar year, accept as noted in the following Test Schedule Table. Test Title Yearly Physical Dimensions X Mean Spherical Candela (MSCD) X External Visual Examination X Color X Leak/Sealability Through Terminals and Seals X Deflection X Fluid Compatibility Terminal Retention X Resonant Frequencies Aged Resonant Frequency Salt Spray Outgassing Temperatures Requirement Laboratory Life at 14.0 VDC X Luminous Intensity Maintenance X Vibration Durability Shock Aged Vibration Durability Terminal Requirements DRL (SAE J2087)
Standard

SPECIFICATION FOR TESTING AUTOMOTIVE HALOGEN LIGHT SOURCES

2002-04-15
HISTORICAL
USCAR14-1
The procedures contained in this specification cover the laboratory testing of replaceable halogen incandescent bulbs for use in automotive road illumination. The following tests are intended to be run under the following conditions. New bulb design Design or process change made to an existing bulb, which could affect the outcome of the test The completion of one calendar year, accept as noted in the following Test Schedule Table. Test Title Yearly Physical Dimensions X Mean Spherical Candela (MSCD) X External Visual Examination X Color X Leak /Sealability Through Terminals and Seals X Deflection X Fluid Compatibility Terminal Retention X Resonant Frequencies Aged Resonant Frequency Salt Spray Outgassing Temperatures Requirement Laboratory Life at 14.0 VDC X Luminous Intensity Maintenance Vibration Durability Shock Aged Vibration Durability Terminal Requirements DRL (SAE J2087)
Standard

Shipping Caps, Torque Caps, and Body Plugs Ergonomic Design Criteria

2015-03-30
CURRENT
USCAR43
This document describes the design and assembly force guidelines for conventional shipping caps, torque caps, and body plugs. All possible design and applications could not be anticipated in creating these guidelines. Where there are questions of adherence to this document, such as use of an “off-the-shelf” design, always consult the responsible Ergonomics Department.
Standard

HIGH VOLTAGE CONNECTOR PERFORMANCE SUPPLEMENT TO SAE/USCAR-2

2008-08-27
CURRENT
USCAR37
Procedures included within this specification supplement are, when used in conjunction with SAE/USCAR 2, intended to cover performance testing at all phases of development, production, and field analysis of electrical terminals, connectors, and components that constitute the electrical connection systems in high voltage (60~600V) road vehicle applications. These procedures are applicable to terminals used for In-Line, Header, and Device Connector systems with and without Shorting Bars. This supplement applies to both sealed and unsealed connection systems.
Standard

SPECIFICATION FOR TESTING AUTOMOTIVE LAMP ASSEMBLIES

2022-03-15
CURRENT
USCAR34
The procedures contained in this specification cover the laboratory testing of Exterior Lamps for use in automotive road illumination. The following tests are intended to be run under the following conditions. This document shall be applied to systems that meet the requirements for design, performance and validation established by government standards. If other manufacture’s components are intended to be approved for use in the lamp assembly, then those possible combinations of components shall be considered a new lamp assembly and shall also be tested.
Standard

PERFORMANCE SPECIFICATION FOR AUTOMOTIVE UNIVERSAL SERIAL BUS (USB) CONNECTION SYSTEM

2022-07-04
HISTORICAL
USCAR30
Procedures included within this specification are intended to cover performance testing at all phases of development, production, and field analysis of any USB cable assemblies and associated connections that constitute the electrical connection systems between the consumer peripheral interface and the USB computer source in road vehicle applications. These procedures are only applicable to the USB connector and the cable. Unless otherwise specified, all of the tests listed in this specification are for both consumer and nonconsumer interface connectors.
Standard

Performance Specification for Ultrasonically Welded Wire/Cable Termination

2009-12-18
HISTORICAL
USCAR38
IMPORTANT NOTICE: In any intended vehicle application, if the products covered by this specification are, or may be, subjected to conditions beyond those described in this document, they must pass special tests simulating the actual conditions to be encountered before they can be considered acceptable for actual vehicle application. Products certified by their supplier as having passed specific applicable portions of this specification are not to be used in applications where conditions may exceed those for which the product has been satisfactorily tested. The Authorized Person is the final authority as to what tests are to be performed on his or her parts and for what purpose these tests are required. He or she is also the final authority for resolving any questions related to testing to this specification and to authorizing any deviations to the equipment or procedures contained in this specification.
Standard

PERFORMANCE STANDARD FOR AUTOMOTIVE ELECTRICAL CONNECTOR SYSTEMS

2001-04-01
HISTORICAL
USCAR2
Procedures included within this specification are intended to cover performance testing at all phases of development, production, and field analysis of electrical terminals, connectors, and components that constitute the electrical connection systems in low voltage (0 - 20 VDC) road vehicle applications. These procedures are only applicable to terminals used for In-Line, Header, and Device connector systems. They are not applicable to Edge Board connector systems, > 20 VAC or DC, or to eyelet type terminals. Note that this specification does not cover the mechanical assist portions of connectors that include such devices. The Authorized Person must provide details of any additional testing desired to validate these mechanisms as part of the test request/order.
X