Refine Your Search

Topic

Author

Search Results

Standard

VHDL-AMS Statistical Analysis Packages

2006-10-23
CURRENT
J2748_200610
This document specifies the interface and the behavior of the VHDL-AMS packages for use in modeling statistical behavior. These packages are useful in defining the statistical variation of parameters of electrical, electronic, and mechatronic components and sub-systems. These can then be used with simulation tools to analyze the performance and reliability of systems composed of these components and sub-systems. Providing a standard definition of the package interfaces and their behavior is intended to facilitate the exchange of models between component and system manufacturers and the use of different CAE simulation tools. The SAE statistical package supports the statistical modeling of design parameters subject to tolerances for designs described using the VHDL or VHDL-AMS languages.
Standard

ELECTROPLATE REQUIREMENTS FOR DECORATIVE CHROMIUM DEPOSITS ON ZINC BASE MATERIALS USED FOR EXTERIOR ORNAMENTATION

1991-06-01
HISTORICAL
J1837_199106
This SAE Standard covers the physical and performance requirements for electrodeposited copper, nickel, and chromium deposits on exterior ornamentation fabricated from die cast zinc alloys (SAE J468 alloys 903 and 925), and wrought zinc strip (ASTM B 69). This type of coating is designed to provide a high degree of corrosion resistance for automotive, truck, marine, and farm usage where a bright, decorative finish is desired.
Standard

Electroplate Requirements for Decorative Chromium Deposits on Zinc Base Materials Used for Exterior Ornamentation

2017-12-20
CURRENT
J1837_201712
This SAE Standard covers the physical and performance requirements for electrodeposited copper, nickel, and chromium deposits on exterior ornamentation fabricated from die cast zinc alloys (SAE J468 alloys 903 and 925), and wrought zinc strip (ASTM B 69). This type of coating is designed to provide a high degree of corrosion resistance for automotive, truck, marine, and farm usage where a bright, decorative finish is desired.
Standard

Tire Size Differential - Articulated Wheel Loader

2019-11-20
CURRENT
J2204_201911
This SAE Standard applies to the usage of tires of the same nominal size and tread type, but with different outside diameter for articulated front-end loaders. Articulated four-wheel-drive front-end loader performance and component life can be affected by excessive differences in the tire outside circumference and/or diameter. The purpose is to provide specific guidelines for the usage of tires with different outside circumference and/or diameter on articulated front-end loaders.
Standard

TIRE SIZE DIFFERENTIAL—ARTICULATED WHEEL LOADER

1994-05-01
HISTORICAL
J2204_199405
This SAE Standard applies to the usage of tires of the same nominal size and tread type, but with different outside diameter for articulated front-end loaders. Articulated four-wheel-drive front-end loader performance and component life can be affected by excessive differences in the tire outside circumference and/or diameter. The purpose is to provide specific guidelines for the usage of tires with different outside circumference and/or diameter on articulated front-end loaders.
Standard

Clamping Force Test Procedure

2018-03-04
CURRENT
J2371_201803
This SAE Recommended Practice is a test procedure to obtain force data for self-compensating type clamps (SAE Type E, CTB, and CTW).
Standard

CLAMPING FORCE TEST PROCEDURE

1997-08-01
HISTORICAL
J2371_199708
This SAE Recommended Practice is a test procedure to obtain force data for self-compensating type clamps (SAE Type E, CTB, and CTW).
Standard

Standard Rainflow File Format

2018-08-24
CURRENT
J2623_201808
This SAE Standard provides a definition of a rainflow file format. This type of simple text file would contain all relevant information about the rainflow cycle content of a time history. Included information are Comments, Signal Range, Signal Mean, Number of Cycles, Signal Maximum, Signal Minimum. Rainflow cycle counting has become the most accepted procedure for identifying material fatigue relevant cycles in complex variable amplitude load time histories. The cycle counting methods account for the effects of material plasticity and material memory of prior deformation, and the resulting compressed history information is used by durability analysts to estimate the effects of a given service or test history.
Standard

Standard Rainflow File Format

2002-04-30
HISTORICAL
J2623_200204
This SAE Standard provides a definition of a rainflow file format. This type of simple text file would contain all relevant information about the rainflow cycle content of a time history. Included information are Comments, Signal Range, Signal Mean, Number of Cycles, Signal Maximum, Signal Minimum. Rainflow cycle counting has become the most accepted procedure for identifying material fatigue relevant cycles in complex variable amplitude load time histories. The cycle counting methods account for the effects of material plasticity and material memory of prior deformation, and the resulting compressed history information is used by durability analysts to estimate the effects of a given service or test history.
Standard

Small Diameter Fuel Line Permeation Test Procedure

2013-01-14
CURRENT
J2996_201301
This SAE Recommended Practice is intended for the determination of the losses of hydrocarbon fluids by permeation through small diameter fuel hose typically 4.75mm ID or less and typically used on Small Off-Road Engines (SORE) less than 19 kW as regulated under 40 CFR Part 1054.
Standard

Thread Sealants

2021-01-27
CURRENT
J1615_202101
Male pipe threads, including male dryseal pipe threads, when made into assemblies or installed into ports, will generally leak if not covered with a sealant. This SAE Recommended Practice is intended as a guide to assist designers and/or users in the selection and application of various types of thread sealants. The designers and users must make a systematic review of each type and application and then select the sealant to fulfill the requirements of the application. The following are general guidelines and are not necessarily a complete list.
X