Refine Your Search

Topic

Search Results

Standard

Aerospace-Particle Count Data Conversion and Extrapolation

2012-09-24
CURRENT
AIR877C
This SAE Aerospace Information Report (AIR) describes a mathematical model that can be used to analyze particle count data. Particle counts that fit the model can be graphically displayed, converted from one counting size-frequency range to another, and extrapolated to estimate counts beyond the measured range. Derivation, applications, and calculations are described.
Standard

Aerospace-Particle Count Data Conversion and Extrapolation

2002-07-23
HISTORICAL
AIR877B
This SAE Aerospace Information Report (AIR) describes a mathematical model that can be used to analyze particle count data. Particle counts that fit the model can be graphically displayed, converted from one counting size-frequency range to another, and extrapolated to estimate counts beyond the measured range. Derivation, applications, and calculations are described.
Standard

AEROSPACE-PARTICLE COUNT DATA CONVERSION AND EXTRAPOLATION

1993-03-02
HISTORICAL
AIR877A
This Aerospace Information Report (AIR) describes a mathematical model that can be used to analyze particle count data. Particle counts that fit the model can be graphically displayed, converted from one counting size-frequency range to another, and extrapolated to estimate counts beyond the measured range. Derivation, applications and calculations are described.
Standard

PARTICLE COUNT DATA CONVERSION AND EXTRAPOLATION

1993-01-01
HISTORICAL
AIR877
This report describes a mathematical model which can be used to analyze particle count data. Particle counts which fit the model can be graphically displayed. converted from one counting size-frequency range to another, and extrapolated to estimate counts beyond the measured range. Derivation, applications and calculations are described.
Standard

PROCEDURE FOR THE DETERMINATION OF PARTICULATE CONTAMINATION OF AIR IN DUST CONTROLLED SPACES BY THE PARTICLE COUNT METHOD

1962-08-30
HISTORICAL
ARP743
This test describes a self-checking procedure for the determination of particulate contaminant five microns or greater in size in air by the particle count method. A maximum variation of two to one (±33% of the average of two runs) in results should be expected for replicate counts on the same sample, providing that the procedure is followed closely and the precautions presented regarding check samples and self-checking aspects are observed.
Standard

Aerospace - Dynamic Test Method for Determining the Relative Degree of Cleanliness of the Downstream Side of Filter Elements

2002-05-21
HISTORICAL
ARP599C
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

AEROSPACE - DYNAMIC TEST METHOD FOR DETERMINING THE RELATIVE DEGREE OF CLEANLINESS OF THE DOWNSTREAM SIDE OF FILTER ELEMENTS

1996-05-01
HISTORICAL
ARP599B
This SAE Aerospace Recommended Practice (ARP) describes a procedure for determining the insoluble contamination level of the downstream side of filter elements. Results of this procedure represent the particulate released from the tested filter element under the prevailing conditions of the test. The results may be used for comparative evaluation of the effectiveness of various cleaning methods or the cleanliness of elements after cleaning or as received from manufacturers.
Standard

Aerospace - Evaluation of Particulate Contamination in Hydraulic Fluid - Membrane Procedure

2008-06-04
HISTORICAL
ARP4285
This SAE Aerospace Recommended Practice (ARP) establishes a method for evaluating the particulate matter extracted from the working fluid of a hydraulic system or component using a membrane. The amount of particulate matter deposited on the membrane due to filtering a given quantity of fluid is visually compared against a standard membrane in order to provide an indication of the cleanliness level of the fluid. A particular feature of this method is the membrane preparation to achieve an even particulate distribution on the membrane suitable for other applications. Membrane evaluation using standard membranes, described in this document, is an alternative technique to counting with either an optical microscope (ARP598) or an automatic particle counter (ISO 11500). The latter particle counting procedures are considered more precise.
Standard

Filter Element Cleaning Methods

2020-10-09
CURRENT
AIR787B
This SAE Aerospace Information Report (AIR) provides technical information to assist the development of specific cleaning methods for those filter elements which are designated as "cleanable" and cannot be cleaned by simple and obvious procedures.
Standard

Filter Element Cleaning Methods

2013-10-08
HISTORICAL
AIR787A
This SAE Aerospace Information Report (AIR) provides technical information to assist the development of specific cleaning methods for filter elements. Consideration is limited to filter elements which are designated as "cleanable" (not "disposable"), but which cannot be cleaned by simple and obvious procedures. Cleaning methods developed according to this report should be evaluated by the methods of ARP725. Satisfactory cleaning methods can be developed for most "cleanable" filter elements. Technical or economic feasibility of the cleaning method may be limited, however, by incompatibility of filter-element construction materials, by mechanical weakness or lack of corrosion resistance to withstand repeated or continued cleaning, or by the presence of unusually tenacious contamination. These factors must be considered when selecting approaches to the development of specific methods.
Standard

FILTER-ELEMENT CLEANING METHODS

1991-11-01
HISTORICAL
AIR787
This Aerospace Information Report provides technical information to assist the development of specific cleaning methods for filter elements. Consideration is limited to filter elements which are designated as "cleanable" (not "disposable"), but which cannot be cleaned by simple and obvious procedures. Cleaning methods developed according to this report should be evaluated by the methods of ARP 725 and ARP 849. Satisfactory cleaning methods can be developed for most "cleanable" filter elements. Technical or economic feasibility of the cleaning method may be limited, however, by incompatibility of filter-element construction materials, by mechanical weakness or lack of corrosion resistance to withstand repeated or continued cleaning, or by the presence of unusually tenacious contamination. These factors must be considered when selecting approaches to the development of specific methods.
Standard

Degradation Limits of Hydrocarbon-Based Hydraulic Fluids, MIL-H-5606, MIL-H-6083, MIL-H-83282, and MIL-H-46170 Used in Hydraulic Test Stands

2001-03-01
HISTORICAL
AIR810C
This SAE Aerospace Information Report (AIR) presents data on normally accepted changes in physical properties and contamination levels for military hydraulic fluids used in hydraulic test stands. This information is of importance to all users of hydraulic test stands to assure the performance data obtained on these test stands for specific components will not be adversely affected by excessive changes in fluid properties or contamination levels. The data pertains to fluids conforming to specifications MIL-H-5606, MIL-H-83282, MIL-H-6063, and MIL-H-46170. The guidelines incorporated in the AIR are the general consensus values of knowledgeable professionals. However, the experience and judgement of engineers and operators responsible for the equipment must be relied upon to determine when the hydraulic fluid is to be replaced. This document is essentially a metric document with English units.
Standard

Degradation Limits of MIL-PRF-5606, MIL-PRF-83282, and MIL-PRF-87257 Hydraulic Fluids Used in Hydraulic Test Stands

2020-10-14
CURRENT
AIR810E
This SAE Aerospace Information Report (AIR) presents data on normally accepted changes in physical properties and contamination levels for MIL-PRF-5606, MIL-PRF-83282, and MIL-PRF-87257 hydraulic fluids used in hydraulic test stands. This information is of importance to all users of hydraulic test stands to assure the performance data obtained on these test stands for specific components will not be adversely affected by excessive changes in fluid properties or contamination levels.
Standard

LIQUID FILTER RATINGS, PARAMETERS AND TESTS

1993-02-03
HISTORICAL
AIR887B
This SAE Aerospace Information Report (AIR) identifies and explains the meaning of various ratings and terms used to describe the physical characteristics of liquid filter elements. The significance of various filter parameters is discussed. In addition, a number of filter test methods is briefly described. This AIR and the data presented are only applicable to filters in which the system liquid wets the filter elements. This document includes equivalent metric units (in parentheses) as referenced information.
X