Standard

SEALED LIGHTING UNITS FOR CONSTRUCTION AND INDUSTRIAL MACHINERY

1980-04-01
HISTORICAL
J598_198004
This recommended practice applies to floodlamp and headlamp units intended for use on off-highway vehicles and machines generally known as earthmoving equipment. Other performance and dimensional information is contained in SAE J572 and SAE J760.
Standard

SEALED LIGHTING UNITS FOR CONSTRUCTION, INDUSTRIAL, AND FOREST MACHINERY

1987-05-01
HISTORICAL
J598_198705
This recommended practice applies to floodlamp, headlamp and general service lamp units intended for use on off-road self-propelled work machines classified as construction (1.1 and 1.2), general purpose industrial (2) and forestry machines (4), as noted on SAE J1116. Construction and Industrial Machinery is normally operated off highways, therefore, this SAE Recommended Practice is not intended to be used as a basis for regulations by those having authority over motor vehicles used on public highways. Other performance and dimensional information is contained in SAE J572 and J760.
Standard

SEALED LIGHTING UNITS FOR CONSTRUCTION, INDUSTRIAL, AND FOREST MACHINERY

1994-06-01
HISTORICAL
J598_199406
This SAE Recommended Practice applies to floodlamp, headlamp, and general service lamp units intended for use on off-road self-propelled work machines classified as construction (1.1 and 1.2), general purpose industrial (2), and forestry machines (4), as noted in SAE J1116. Construction and Industrial Machinery is normally operated off highways; therefore, this document is not intended to be used as a basis for regulations by those having authority over motor vehicles used on public highways. Other performance and dimensional information is contained in SAE J572 and J760.
Standard

SOUND POWER LEVEL MEASUREMENTS - EARTHMOVING MACHINERY (DOZER, LOADER, EXCAVATOR, AND BACKHOE) - IN PLACE DYNAMIC - SOUND PRESSURE LEVEL OR SOUND INTENSITY METHOD

1987-04-01
HISTORICAL
J1805_198704
The requirements for setting up and operating the machinery, the microphone array and hemispherical measurement surface are given in this document. This document shall be used in conjunction with manufacturer's recommendations pending finalization of ANSI documents on the subject of sound intensity procedures. The accompanying sound intensity procedure clarification is provided pending more widespread understanding of sound intensity.
Standard

OPERATOR SOUND LEVEL MEASUREMENT PROCEDURE FOR POWERED MOBILE CONSTRUCTION MACHINERY—SINGULAR TYPE TEST

1976-03-01
HISTORICAL
J919B_197603
This SAE Recommended Practice sets forth the instrumentation and procedures to be used in measuring sound levels at the operator station for powered mobile construction machinery of 15 kW (20 bhp) rated and over. This Recommended Practice is to cover machinery that has operator stations where the operator can either stand or sit and will be transported by the machine during its operation. The sound levels obtained by using the test procedures set forth in this SAE Recommended Practice are in general repeatable and are representative of the higher range of the sound levels generated by the machinery under field operating conditions, but do not necessarily represent the equivalent sound level over a field use cycle.
Standard

EXTERIOR SOUND LEVEL MEASUREMENT PROCEDURE FOR POWERED MOBILE CONSTRUCTION EQUIPMENT

1972-11-01
HISTORICAL
J88_197211
This SAE Recommended Practice sets forth the instrumentation and procedure to be used in measuring exterior sound levels for powered mobile construction equipment of 20 rated bhp and over. It is not intended to cover operation of safety devices (such as backup alarms) and equipment designed primarily for operation on highways or within factories and building areas, aircraft, or recreational vehicles, such as snowmobiles and boats. The sound levels obtained by using the test procedures set forth in this SAE Recommended Practice are repeatable and representative of the sound levels generated by the equipment during normal operating conditions.
Standard

Sound Measurement - Construction Site

2021-07-15
CURRENT
J1075_202107
This SAE Standard sets forth measurement procedures and instrumentation to be used for determining a “representative” sound level during a representative time period at selected measurement locations on a construction site boundary. The document is not intended for use in determining occupational hearing damage risk. Determination of a representative time period is left to the judgment of the user.
Standard

Sound Measurement—Construction Site

2007-11-09
HISTORICAL
J1075_200711
This SAE Standard sets forth measurement procedures and instrumentation to be used for determining a “representative” sound level during a representative time period at selected measurement locations on a construction site boundary. The document is not intended for use in determining occupational hearing damage risk. Determination of a representative time period is left to the judgment of the user.
Standard

Sound Measurement - Construction Site

2013-03-19
HISTORICAL
J1075_201303
This SAE Standard sets forth measurement procedures and instrumentation to be used for determining a “representative” sound level during a representative time period at selected measurement locations on a construction site boundary. The document is not intended for use in determining occupational hearing damage risk. Determination of a representative time period is left to the judgment of the user.
Standard

MEASUREMENT PROCEDURE FOR DETERMINING A REPRESENTATIVE SOUND LEVEL AT A CONSTRUCTION SITE BOUNDARY LOCATION

1978-04-01
HISTORICAL
J1075_197804
This SAE Recommended Practice sets forth procedures and instrumentation to be used for determining a representative sound level during a representative time period at selected measurement locations on a construction site boundary. It concerns the community adjacent to the construction site, and it is not intended for use in determining occupational hearing damage risk.
Standard

SOUND MEASUREMENT—CONSTRUCTION SITE

1985-04-01
HISTORICAL
J1075_198504
This SAE Recommended Practice sets forth measurement procedures and instrumentation to be used for determining a “representative” sound level during a representative time period at selected measurement locations on a construction site boundary. The practice is not intended for use in determining occupational hearing damage risk. Determination of a representative time period is left to the judgement of the user.
Standard

SOUND MEASUREMENT—CONSTRUCTION SITE

1985-08-01
HISTORICAL
J1075_198508
This SAE Recommended Practice sets forth measurement procedures and instrumentation to be used for determining a “representative” sound level during a representative time period at selected measurement locations on a construction site boundary. The practice is not intended for use in determining occupational hearing damage risk. Determination of a representative time period is left to the judgement of the user.
Standard

SOUND MEASUREMENT - CONSTRUCTION SITE

1987-03-01
HISTORICAL
J1075_198703
This SAE Standard sets forth measurement procedures and instrumentation to be used for determining a "representative" sound level during a representative time period at selected measurement locations on a construction site boundary. The standard is not intended for use in determining occupational hearing damage risk. Determination of a representative time period is left to the judgment of the user.
Standard

OPERATOR STATION SOUND LEVEL MEASUREMENT PROCEDURE FOR POWERED MOBILE EARTHMOVING MACHINERY—WORK CYCLE TEST

1976-12-01
HISTORICAL
J1166_197612
This SAE Recommended Practice sets forth the procedures to be used only in measuring sound levels and the determination of the time weighted average sound level at the operator station(s) of powered mobile earthmoving machinery of 15 kW (20 bhp) and over. This Recommended Practice is applicable to earthmoving machinery which has operator station(s) where the operator can either stand or sit and is transported by the machinery during its operation. The Recommended Practice describes the instrumentation requirements and specifies work cycles for earthmoving machinery. The Recommended Practice describes the method used to calculate the time weighted average sound level at the operator station(s)—identified in this practice as Leq(5)—for continuous operation on the work cycle. A method to relate the time weighted average sound level at the operator station(s) to operator sound exposure is also provided.