Refine Your Search

Search Results

Viewing 1 to 6 of 6
Technical Paper

A Combustion Products Analyzer for Contingency Use During Thermodegradation Events on Spacecraft

1991-07-01
911479
As mission length and the number and complexity of payload experiments increase, so does the probability of thermodegradation contingencies (e.g. fire, chemical release and/or smoke from overheated components or burning materials), which could affect mission success. When a thermodegradation event occurs on board a spacecraft, potentially hazardous levels of toxic gases could be released into the internal atmosphere. Experiences on board the Space Shuttle have clearly demonstrated the possibility of small thermodegradation events occurring during even relatively short missions. This paper will describe the Combustion Products Analyzer (CPA), which is being developed under the direction of the Toxicology Laboratory at Johnson Space Center to provide necessary data on air quality in the Shuttle following a thermodegradation incident.
Technical Paper

Results of the Risk Mitigation Experiment for the Volatile Organic Analyzer

1998-07-13
981745
A volatile organic analyzer (VOA), developed by Graseby Dynamics, Ltd. under contract to the Johnson Space Center Toxicology Laboratory, is the core instrument for trace contaminant monitoring on the International Space Station (ISS). The VOA will allow trace amounts of target compounds to be analyzed in real time so that ISS air quality can be assessed in nominal and contingency situations. Recent events on Mir have underscored the need for real-time analysis of air quality so that the crew can respond promptly during off-nominal conditions. The VOA, which is based on gas chromatography/ion mobility spectrometry, is the first spacecraft instrument to be used for such a complex task. Consequently, a risk mitigation experiment (VOA/RME) was flown to assess the performance and engineering aspects of the VOA. This paper is a review of VOA/RME results from the STS-81 and STS-89 flights and their implications for the ISS VOA design and operations.
Technical Paper

The Portable Monitor for Measuring Combustion Products Aboard the International Space Station

2002-07-15
2002-01-2298
The Toxicology Laboratory at Johnson Space Center (JSC) had provided the combustion products analyzer (CPA) since the early 1990s to monitor the spacecraft atmosphere in real time if a thermodegradation event occurred aboard the Shuttle. However, as the operation of the International Space Station (ISS) grew near, an improved CPA was sought that would include a carbon monoxide sensor that did not have a cross-sensitivity to hydrogen. The Compound Specific Analyzer-Combustion Products (CSA-CP) was developed for use on the International Space Station (ISS). The CSA-CP measures three hazardous gases, carbon monoxide, hydrogen cyanide, and hydrogen chloride, as well as oxygen. The levels of these compounds in the atmosphere following a thermodegradation event serve as markers to determine air quality. The first permanent ISS crew performed the CSA-CP checkout operations and collected baseline data shortly after arrival aboard the ISS in December 2000.
Technical Paper

A Review of Monitoring Technologies for Trace Air Contaminants in the International Space Station

2004-07-19
2004-01-2339
NASA issued a Request For Information (RFI) to identify technologies that might be available to monitor a list of air pollutants in the ISS atmosphere. After NASA received responses to the RFI, an expert panel was assembled to hear presentations from 9 technology proponents. The goal of the panel was to identify technologies that might be suitable for replacement of the current Volatile Organics Analyzer (VOA) within several years. The panelists consisted of 8 experts in analytical chemistry without any links to NASA and 7 people with specific expertise because of their roles in NASA programs. Each technology was scored using a tool that enabled rating of many specific aspects of the technology on a 4-point system. The maturity of the technologies ranged from well-tested instrument packages that had been designed for space applications and were nearly ready for flight to technologies that were untested and speculative in nature.
Technical Paper

Toxicological Assessment of Sealed Spacecraft Modules

1999-07-12
1999-01-2055
Spacecraft modules that are last purged with clean air several months before they are entered by humans on orbit require careful management. The crew must not be exposed to harmful concentrations of air pollutants when they first enter. The magnitude of the pollution the crew will encounter depends on the volume of the module, the length of time since the last clean-air purge or scrub, the inherent offgassing rate of the materials in the module, the interior temperature of the module while offgassing occurs, and the system leak rate. The time of the last module purge or scrub can be several months before crew entry, so it is essential that the offgassing rate within the module be measured over a suitable interval of time to estimate pollution levels with confidence. Air samples were taken from the STS-74 Russian Docking Module, the STS-79 Spacehab, and the ISS Node 1 prior to launch to predict pollution levels at crew first entry.
Technical Paper

A Second Generation Volatile Organic Analyzer for the International Space Station

1999-07-12
1999-01-2059
Experiences during the Shuttle and NASA/Mir programs illustrated the need for a real-time volatile organic analyzer (VOA) to assess the impact of air quality disruptions on the International Space Station (ISS). Toward this end, a joint development by the Toxicology Laboratory at Johnson Space Center and Graseby Dynamics (Watford, UK) produced a 1st generation VOA that has been delivered and is ready for the first 5 years of ISS operation. Criteria for the selection of the 1st generation VOA included minimizing the size, weight, and power consumption while maintaining analytical performance. Consequently, a VOA system based upon gas chromatography/ion mobility spectrometry (GC/IMS) was selected in the mid-90’s. A smaller, less resource-intensive device than the 1st generation VOA will be needed as NASA looks beyond ISS operations. During the past three years, efforts to reduce the size of ion mobility spectrometers have been pursued.