Refine Your Search

Search Results

Viewing 1 to 3 of 3
Technical Paper

Biomechanical Response of the Pediatric Abdomen, Part 1: Development of an Experimental Model and Quantification of Structural Response to Dynamic Belt Loading

2006-11-06
2006-22-0001
The abdomen is the second most commonly injured region in children using adult seat belts, but engineers are limited in their efforts to design systems that mitigate these injuries since no current pediatric dummy has the capability to quantify injury risk from loading to the abdomen. This paper develops a porcine (sus scrofa domestica) model of the 6-year-old human's abdomen, and then defines the biomechanical response of this abdominal model. First, a detailed abdominal necropsy study was undertaken, which involved collecting a series of anthropometric measurements and organ masses on 25 swine, ranging in age from 14 to 429 days (4-101 kg mass). These were then compared to the corresponding human quantities to identify the best porcine representation of a 6-year-old human's abdomen. This was determined to be a pig of age 77 days, and whole-body mass of 21.4 kg.
Technical Paper

Pediatric Thoracoabdominal Biomechanics

2009-11-02
2009-22-0013
No experimental data exist quantifying the force-deformation behavior of the pediatric chest when subjected to non-impact, dynamic loading from a diagonal belt or a distributed loading surface. Kent et al., (2006) previously published juvenile abdominal response data collected using a porcine model. This paper reports on a series of experiments on a 7-year-old pediatric post-mortem human subject (PMHS) undertaken to guide the scaling of existing adult thoracic response data for application to the child and to assess the validity of the porcine abdominal model. The pediatric PMHS exhibited abdominal response similar to the swine, including the degree of rate sensitivity. The upper abdomen of the PMHS was slightly stiffer than the porcine behavior, while the lower abdomen of the PMHS fit within the porcine corridor. Scaling of adult thoracic response data using any of four published techniques did not successfully predict the pediatric behavior.
Technical Paper

Assessment of a Three-Point Restraint System with a Pre-tensioned Lap Belt and an Inflatable, Force-Limited Shoulder Belt

2011-11-07
2011-22-0007
This study investigates the performance of a 3-point restraint system incorporating an inflatable shoulder belt with a nominal 2.5-kN load limiter and a non-inflatable lap belt with a pretensioner (the “Airbelt”). Frontal impacts with PMHS in a rear seat environment are presented and the Airbelt system is contrasted with an earlier 3-point system with inflatable lap and shoulder belts but no load-limiter or pretensioners, which was evaluated with human volunteers in the 1970s but not fully reported in the open literature (the “Inflataband”). Key differences between the systems include downward pelvic motion and torso recline with the Inflataband, while the pelvis moved almost horizontally and the torso pitched forward with the Airbelt. One result of these kinematic differences was an overall more biomechanically favorable restraint loading but greater maximum forward head excursion with the Airbelt.
X