Refine Your Search

Search Results

Viewing 1 to 20 of 20
Journal Article

Effects of B20 versus ULSD Fuel on Diesel Engine PM Emissions and Aftertreatment Performance

2010-04-12
2010-01-0790
A detailed study is undertaken to examine how 2010+ diesel engine exhaust emissions change when a soybean-derived B20 biodiesel fuel is used instead of a conventional ultra-low sulfur diesel fuel and to investigate how these changes impact the aftertreatment system. Particulate matter (PM) emissions for each fuel are characterized in terms of mass emissions, size distributions, organic versus soot fraction, metals content, and particle morphology. PM mass recorded by Dekati Mass Monitor, thermal analysis of quartz filters, and calculated from particle size distributions consistently shows a 2 - 3 fold decrease in engine-out soot emissions over a wide mid-load range when changing from ULSD to B20 fuel. This is partly due to a decrease in particle number and partly to a decrease in average size. HC and NO emissions, in contrast, exhibit little change with fuel type.
Technical Paper

How Well Can mPEMS Measure Gas Phase Motor Vehicle Exhaust Emissions?

2020-04-14
2020-01-0369
“Real world emissions” is an emerging area of focus in motor vehicle related air quality. These emissions are commonly recorded using portable emissions measurement systems (PEMS) designed for regulatory application, which are large, complex and costly. Miniature PEMS (mPEMS) is a developing technology that can significantly simplify on-board emissions measurement and potentially promote widespread use. Whereas full PEMS use analyzers to record NOx, CO, and HCs similar to those in emissions laboratories, mPEMS tend to use electrochemical sensors and compact optical detectors for their small size and low cost. The present work provides a comprehensive evaluation of this approach. It compares measurements of NOx, CO, CO2 and HC emissions from five commercial mPEMS to both laboratory and full regulatory PEMS analyzers. It further examines the use of vehicle on-board diagnostics data to calculate exhaust flow, as an alternative to on-vehicle exhaust flow measurement.
Technical Paper

How Well Can mPEMS Measure Particulate Matter Motor Vehicle Exhaust Emissions?

2020-04-14
2020-01-0391
Real world emissions are increasingly the standard of comparison for motor vehicle exhaust impact on the environment. The ability to collect such data has thus far relied primarily on full portable emissions measurement systems (PEMS) that are bulky, expensive, and time consuming to set up. The present work examines four compact, low cost, miniature PEMS (mPEMS) that offer the potential to expand our ability to record real world exhaust emissions over a larger number of operating conditions and combustion engine applications than currently possible within laboratory testing. It specifically addresses the particulate matter (PM) capabilities of these mPEMS, which employ three different methodologies for particle measurement: diffusion charger, optical scattering, and a multi-sensor approach that combines scattering, opacity, and ionization. Their performance is evaluated against solid particle number and PM mass with both vehicle tests and flame generated soot.
Journal Article

Sampling of Non-Volatile Vehicle Exhaust Particles: A Simplified Guide

2012-04-16
2012-01-0443
Recently, a particle number (PN) limit was introduced in the European light-duty vehicles legislation. The legislation requires measurement of PN, and particulate mass (PM), from the full dilution tunnel with constant volume sampling (CVS). Furthermore, PN measurements will be introduced in the next stage of the European Heavy-Duty regulation. Heavy-duty engine certification can be done either from the CVS or from a partial flow dilution system (PFDS). For research and development purposes, though, measurements are often conducted from the raw exhaust, thereby avoiding the high installation costs of CVS and PFDS. Although for legislative measurements requirements exist regarding sampling and transport of the aerosol sample, such requirements do not necessarily apply for raw exhaust measurements. Thus, measurement differences are often observed depending on where in the experimental set up sampling occurs.
Journal Article

Overview of Soot Emission Measurements Instrumentation: From Smoke and Filter Mass to Particle Number

2013-03-25
2013-01-0138
Particulate emissions cause adverse health effects and for this reason they are regulated since the 80s. Vehicle regulations cover particulate emission measurements of a model before its sale, known as type approval or homologation. For heavy-duty engines the emissions are measured on an engine dynamometer with steady state points and transient cycles. For light-duty vehicles (i.e. the full power train) the particulate emissions are assessed on a chassis dynamometer. The measurement of particulate emissions is conducted either by diluting the whole exhaust in a dilution tunnel with constant volume sampling or by extracting a small proportional part of the exhaust gas and diluting it. Particulate emissions are measured by passing part of the diluted exhaust aerosol through a filter paper. The increase of the weight of the filter is used to calculate the particulate matter mass (PM) emissions.
Journal Article

A New Approach for Very Low Particulate Mass Emissions Measurement

2013-04-08
2013-01-1557
Pending reductions in light duty vehicle PM emissions standards from 10 to 3 mg/mi and below will push the limits of the gravimetric measurement method. At these levels the PM mass collected approaches the mass of non-particle gaseous species that adsorb onto the filter from exhaust and ambient air. This introduces an intrinsic lower limit to filter based measurement that is independent of improvements achieved in weighing metrology. The statistical variability of back-up filter measurements at these levels makes them an ineffective means for correcting the adsorption artifact. The proposed subtraction of a facility based estimate of the artifact will partially alleviate the mass bias from adsorption, but its impact on weighing variability remains a problem that can reach a significant fraction of the upcoming 3 and future 1 mg/mi standards. This paper proposes an improved PM mass method that combines the gravimetric filter approach with real time aerosol measurement.
Technical Paper

Measurement of Dry Soot and Particulate Matter from Two-Stroke and Four-Stroke Snowmobiles

2010-09-28
2010-32-0042
Recent increases in emissions regulations within the snowmobile industry have led to significant advancements in fuel, exhaust, and control systems on snowmobiles. However, particulate matter is currently an unregulated exhaust component of snowmobile engines. The measurement of dry soot as well as particulate matter from snowmobiles is the focus of this paper. Two industry-representative snowmobiles were chosen for this research which included a 2006 Yamaha Nytro carbureted four-stroke and a 2009 Ski-Doo MX-Z direct-injected two-stroke. Measurements for each snowmobile included gaseous emissions (CO₂, CO, NOx, O₂, and THC), particulate matter collected on quartz filters, and dry soot measured using an AVL Micro Soot Sensor. Each snowmobile was tested over the industry-standard five-mode emissions certification test cycle to determine the emissions, dry soot, and particulate matter levels from idle to wide open throttle (full-load).
Technical Paper

A Photoacoustic Sensor System for Time Resolved Quantification of Diesel Soot Emissions

2004-03-08
2004-01-0968
The reduction of particulate emissions limits requires new tools for the tuning of engines and exhaust aftertreatment systems. Time-resolved monitoring of low soot emissions is a key feature for such developments. The paper describes an improved photoacoustic soot sensor, and presents its applications for the characterization of transient exhaust soot emissions before and after Diesel emission after-treatment systems. The detection limit of the unit is around 5 μg/m3 soot, which is two orders of magnitude better than conventional time-resolved transmission measurement. Additionally, a wide dynamic range of four orders of magnitude can be achieved without range switching. The photoacoustic signal is proportional to the soot mass, no significant cross-sensitivities to gaseous absorbers were detected.
Technical Paper

Diesel Particulate Measurement with Partial Flow Sampling: Systems A New Probe and Tunnel Design that Correlates with Full Flow Tunnels

2002-03-04
2002-01-0054
Partial flow sampling methods in emissions testing are interesting and preferred because of their lower cost, smaller size and applicability to engines of all sizes. However the agreement of the results obtained with instruments based on this method to those obtained with the traditional, large tunnel full flow sampling systems needs to be achieved, and the factors of construction that influence this agreement must be understood. These issues have received more attention lately in connection with ISO and WHDC standardization efforts underway to achieve a world-wide harmony in the sampling methods for heavy duty diesel engines, and with the introduction of similar Bag-minidiluter techniques into light duty SULEV gaseous pollutant measurement. This paper presents the theory and practice of a partial flow probe and tunnel design that addresses and minimizes the undesirable effects of the necessary differences between the two sampling methods.
Technical Paper

DVE - Direct Vehicle Exhaust Flow Measurement using Head-type Flowmeters

2003-03-03
2003-01-0782
When exhaust emissions from a vehicle are measured, a flow rate is needed in addition to pollutant concentrations in order to calculate the mass emitted. The highly unsteady flow from an internal combustion engine presents measurement challenges to exhaust flowmeters, especially at idle. Mass measurement methods used in the past have gotten around this problem by a variable dilution scheme (CVS) that measures a different, more favorable flow, but reduces and can contaminate exhaust gas concentration levels. The flow measurement system described here makes possible a more accurate measure of the vehicle exhaust flow by means of a number of design features. This improves considerably the cost effectiveness and accuracy of emissions measurement techniques such as the Bag-Minidiluter sampling system and raw modal analysis.
Technical Paper

Accuracy of Particle Number Measurements from Partial Flow Dilution Systems

2011-09-11
2011-24-0207
The measurement of the particle number (PN) concentration of non-volatile particles ≻23 nm was introduced in the light-duty vehicles regulation; the heavy-duty regulation followed. Based on the findings of the Particle Measurement Program (PMP), heavy-duty inter-laboratory exercise, the PN concentration measurement can be conducted either from the full dilution tunnel with constant volume sampling (CVS) or from the partial flow dilution system (PFDS). However, there are no other studies that investigate whether the PN results from the two systems are equivalent. In addition, even the PMP study never investigated the uncertainty that is introduced at the final result from the extraction of a flow by a PN system from the PFDS. In this work we investigate the uncertainty for the three possible cases, i.e., considering a constant extracted flow from the PFDS, sending a signal with 1 Hz frequency to the PFDS, or feeding back the extracted flow to the PFDS.
Technical Paper

Feasibility of Particulate Mass and Number Measurement with Portable Emission Measurement Systems (PEMS) for In-Use Testing

2011-09-11
2011-24-0199
Different particulate mass (PM) portable emission measurement systems (PEMS) were evaluated in the lab with three heavy-duty diesel engines which cover a wide range of particle emission levels. For the two engines without Diesel Particulate Filters (DPF) the proportional partial flow dilution systems SPC-472, OBS-TRPM, and micro-PSS measured 15% lower PM than the full dilution tunnel (CVS). The micro soot sensor (MSS), which measures soot in real time, measured 35% lower. For the DPF-equipped engine, where the emissions were in the order of 2 mg/kWh, the systems had differences from the CVS higher than 50%. For on-board testing a real-time sensor is necessary to convert the gravimetric (filter)-based PM to second-by-second mass emissions. The detection limit of the sensor, the particle property it measures (e.g., number, surface area or mass, volatiles or non-volatiles) and its calibration affect the estimated real-time mass emissions.
Technical Paper

Evaluation of Partial Flow Dilution Methodology for Light Duty Particulate Mass Measurement

2013-04-08
2013-01-1567
Two different implementations of Partial Flow Dilution (PFD) methodology designed for gravimetric particulate matter (PM) sampling are evaluated for applicability to light-duty chassis emissions testing. Filter PM measurements were collected and compared to constant volume sampler (CVS) full dilution tunnel PM filter measurements and other real-time PM measurement technologies, using gasoline vehicles generating a range of 0.1 to 10.0 mg/mile PM. Exhaust samples were collected for each phase of the Federal Test Procedure (FTP-75) with a fourth filter sample collected for the US06 supplemental cycle. Both PFDs satisfactorily met proportionality criteria for conventional combustion engines, but some improvements are needed for hybrid electric vehicles (HEVs). The PM mass collected scaled linearly with the CVS tunnel samples, with slopes of 1.03 and 0.74 for the two PFDs.
Technical Paper

Investigation of EURO-5/6 Level Particle Number Emissions of European Diesel Light Duty Vehicles

2010-04-12
2010-01-0789
Particle number emissions are measured with two instruments according to the upcoming European emission regulations for light-duty diesel passenger vehicles and compared to data from other methods, including the current regulatory total particulate matter (PM) mass, photo-acoustic soot sensor (PASS) and engine exhaust particle sizer (EEPS). At the very low emission levels of diesel particulate filter (DPF) equipped vehicles, the solid particle number data correlate well with soot mass and with particle number measured by EEPS, if only those particles belonging to the accumulation mode are considered in the latter case. PN differences of ≻100% between tests of the same vehicle are observed. Comparison of the two PN instruments and the photoacoustic soot sensor show that these are systematic differences which originate primarily with the vehicle and not from instrument uncertainties.
Technical Paper

CMS - An Evolution of the CVS - A Full Flow, Constant Mass Flow, Sampling System

2006-04-03
2006-01-1514
The CMS system commissioned by EPA and built by AVL, is a “start from a clean sheet of paper” approach to a full flow sampling system for aerosol matter from engine exhaust. The challenge of measuring 2007 level post DPF type particulate matter and polyaromatic hydrocarbons led to this re-thinking of sampler design. Previously used CVS designs had evolved to include elements that were not ideally suited for scaling up to large flow rates, and had mixing tunnels that were less than ideal for the sampling of complicated aerosols. The solution presented in this paper used ultrasonic time-of-flight flowmeters in place of the usual Venturi flow tubes, reducing the size and cost of air handling components. Acoustically designed dampeners were used to reduce pulsation disturbances to the flow measurement.
Technical Paper

A New Device for Transient Measurement of Ultralow Soot Emissions

2004-11-16
2004-01-3267
Future legislation, like EURO IV and EURO V or the US 2007 HD regulation will have massive reduction of particulate emission limits. For this beside improvement of engine combustion also exhaust aftertreatment systems are under investigation, like Diesel Particulate Filters (DPF), or Selective Catalytic Reduction (SCR) of Nitrogen Oxides. For all those tasks transient soot emission monitoring is one of the key features. To meet this demand a new device for the on-line measurement of soot emitted by combustion engines has been developed. Based on the photoacoustic principle, which has been optimized for automotive applications and easy use in test cells, the instrument shows a sensitivity of 5μg/m3, which is lower than current particulate immission standards in ambient air, and a time resolution of 1 sec. In the paper first the principles of measurement are shown, and then the specifications and results from measurements of very low soot concentration in the exhaust gas are presented.
Technical Paper

Dynamic Measurements of Particulate Mass Emission on Light-Duty Diesel Engines under Steady State and Transient Conditions

1985-03-01
850269
Real-time measurements of the particulate emission of a light duty Diesel engine mounted on a dynamic test bed are reported. These measurements were performed using a novel device for the simultaneous dynamic determination of graphitic (“black”) smoke and hydrocarbon mass loading in the undiluted exhaust with a time resolution of 0.1 sec. For a given speed and load significant differences between the emissions under steady state and transient conditions were observed. The typical features of these deviations were different for the graphitic particulates and the hydrocarbons.
Technical Paper

Gasoline Particulate Filter Efficiency and Backpressure at Very Low Mileage

2018-04-03
2018-01-1259
The need for gasoline particulate filter (GPF) technology is expected to grow with increasingly tight particle emissions standards being implemented in US, EU, China and elsewhere. Derived from the successful experience with diesel particulate filters (DPF), GPFs adopted the characteristic alternately plugged honeycomb structure that provides a large area of porous cordierite wall for filtering particles with minimal additional backpressure. However, unlike DPFs, continuous soot regeneration in GPFs makes it difficult to grow and sustain the soot cake on the filter wall that gives DPFs their high filtration efficiency. Therefore, filtration performance of low mileage GPFs relies heavily on the porous structure of filter media, which depends on both the substrate and the applied washcoat. In this work, a blank, two fresh washcoated filters and two washcoated filters with 3000 km mileage accumulation were characterized to compare their filtration performance.
Technical Paper

Using Artificial Ash to Improve GPF Performance at Zero Mileage

2019-04-02
2019-01-0974
Gasoline particulate filters (GPF) with high filtration efficiency (>80%) at zero mileage are in growing demand to meet increasingly tight vehicle emission standards for particulate matter being implemented in US, EU, China and elsewhere. Current efforts to achieve high filter performance mainly focus on fine-tuning the filter structure, such as the pore size distribution and porosity of the bare substrate, or the washcoat loading and location of catalyzed substrates. However, high filtration efficiency may have a cost in high backpressure that negatively affects engine power. On the other hand, it has been recognized in a few reports that very low amounts of ash deposits (from non-combustible residue in the exhaust) can significantly increase filtration efficiency with only a mild backpressure increase.
Journal Article

Using Ejector Diluters to Sample Vehicle Exhaust at Elevated Pressures and Temperatures

2008-10-06
2008-01-2434
This paper presents an alternative and relatively simple method which allows the use of ordinary ejector-type diluters over a wide range of sample inlet conditions including elevated pressures and temperatures. After calibration of the ejector diluter, the dilution can be accurately characterized using only the pressures at the inlet and the outlet of the diluter and the sample temperature. The method is based on a semi-empirical, stationary model taking into account the critical parameters needed to predict the dilution factor. Under steady state operation it achieves accuracies estimated to be below ±8% (95% confidence interval) for diluter inlet pressures in the range of 1000 - 4000 mbar absolute and temperatures between 20 - 200°C. Performance under actual vehicle testing conditions is evaluated upstream of the DPF for a diesel vehicle run on a chassis dynamometer.
X