Refine Your Search

Search Results

Viewing 1 to 13 of 13
Journal Article

Thermal Characterization of a Li-ion Battery Module Cooled through Aluminum Heat-Sink Plates

2011-09-13
2011-01-2248
The temperature distribution is studied theoretically in a battery module stacked with 12 high-power Li-ion pouch cells. The module is cooled indirectly with ambient air through aluminum heat-sink plates or cooling plates sandwiched between each pair of cells in the module. Each of the cooling plates has an extended cooling fin exposed in the cooling air channel. The cell temperatures can be controlled by changing the air temperature and/or the heat transfer coefficient on the cooling fin surfaces by regulating the air flow rate. It is found that due to the high thermal conductivity and thermal diffusivity of the cooling plates, heat transfer of the cooling plate governs the cell temperature distribution by spreading the cell heat over the entire cell surface. Influence of thermal from the cooling fins is also simulated.
Journal Article

Thermal Analysis of a High-Power Lithium-Ion Battery System with Indirect Air Cooling

2012-04-16
2012-01-0333
Thermal behavior of a lithium-ion (Li-ion) battery module for hybrid electrical vehicle (HEV) applications is analyzed in this study. The module is stacked with 12 high-power pouch Li-ion battery cells. The cells are cooled indirectly with air through aluminum fins sandwiched between each two cells in the module, and each of the cooling fins has an extended cooling surface exposed in the cooling air flow channel. The cell temperatures are analyzed using a quasi-dimensional model under both the transient module load in a user-defined cycle for the battery system utilizations and an equivalent continuous load in the cycle. The cell thermal behavior is evaluated with the volume averaged cell temperature and the cell heat transfer is characterized with resistances for all thermal links in the heat transfer path from the cell to the cooling air. Simulations results are compared with measurements. Good agreement is observed between the simulated and measured cell temperatures.
Technical Paper

Reducing Temperature Gradients in High-Power, Large-Capacity Lithium-Ion Cells through Ultra-High Thermal Conductivity Heat Spreaders Embedded in Cooling Plates for Battery Systems with Indirect Liquid Cooling

2013-04-08
2013-01-0234
For lithium-ion battery systems assembled with high-capacity, high-power pouch cells, the cells are commonly cooled with thin aluminum cooling plates in contact with the cells. The cooling plates extract the cell heat and dissipate it to a cooling medium (air or liquid). During the pack utilizations with high-pulse currents, large temperature gradients along the cell surfaces can be encountered as a result of non-uniform distributions of the ohmic heat generated in the cells. The non-uniform cell temperature distributions can be significant for large-size cells. Maximum cell temperatures typically occur near the cell terminal tabs as a result of the ohmic heat of the terminal tabs and connecting busbars and the high local current densities. In this study, a new cooling plate is proposed for improving the uniformity in temperature distributions for the cells with large capacities.
Journal Article

Electro-Thermal Modeling of a Lithium-ion Battery System

2010-10-25
2010-01-2204
Lithium-ion (Li-ion) batteries are becoming widely used high-energy sources and a replacement of the Nickel Metal Hydride batteries in electric vehicles (EV), hybrid electric vehicles (HEV) and plug-in hybrid electric vehicles (PHEV). Because of their light weight and high energy density, Li-ion cells can significantly reduce the weight and volume of the battery packs for EVs, HEVs and PHEVs. Some materials in the Li-ion cells have low thermal stabilities and they may become thermally unstable when their working temperature becomes higher than the upper limit of allowed operating temperature range. Thus, the cell working temperature has a significant impact on the life of Li-ion batteries. A proper control of the cell working temperature is crucial to the safety of the battery system and improving the battery life. This paper outlines an approach for the thermal analysis of Li-ion battery cells and modules.
Technical Paper

Comparative Study of Thermal Characteristics of Lithium-ion Batteries for Vehicle Applications

2011-04-12
2011-01-0668
Lithium ion batteries can be developed for vehicle applications from high power specification to high energy specification. Thermal response of a battery cell is the main factor to be considered for battery selection in the design of an electrified vehicle because some materials in the cells have low thermal stability and they may become thermally unstable when their working temperature becomes higher than the upper limit of allowed operating range. In this paper the thermal characteristics of different sizes and forms of commercially available batteries is investigated through electro-thermal analysis. The relation between cell capacity and cell internal resistance is also studied. The authors find that certain criteria can be defined for battery selection for electric vehicles, hybrid electric vehicles and plug-in hybrid electric vehicles. These criteria can be served as design guidelines for battery development for vehicle applications.
Journal Article

Characterizing Thermal Runaway of Lithium-ion Cells in a Battery System Using Finite Element Analysis Approach

2013-04-08
2013-01-1534
In this study, thermal runaway of a 3-cell Li-ion battery module is analyzed using a 3D finite-element-analysis (FEA) method. The module is stacked with three 70Ah lithium-nickel-manganese-cobalt (NMC) pouch cells and indirectly cooled with a liquid-cooled cold plate. Thermal runaway of the module is assumed to be triggered by the instantaneous increase of the middle cell temperature due to an abusive condition. The self-heating rate for the runaway cell is modeled on the basis of Accelerating Rate Calorimetry (ARC) test data. Thermal runaway of the battery module is simulated with and without cooling from the cold plate; with the latter representing a failed cooling system. Simulation results reveal that a minimum of 165°C for the middle cell is needed to trigger thermal runaway of the 3-cell module for cases with and without cold plate cooling.
Technical Paper

Characterizing Thermal Behavior of an Air-Cooled Lithium-Ion Battery System for Hybrid Electrical Vehicle Applications Using Finite Element Analysis Approach

2013-04-08
2013-01-1520
Thermal behavior of a Lithium-ion (Li-ion) battery module under a user-defined cycle corresponding to hybrid electrical vehicle (HEV) applications is analyzed. The module is stacked with 12 high-power 8Ah pouch Li-ion battery cells connected in series electrically. The cells are cooled indirectly with air through aluminum cooling plate sandwiched between each pair of cells. The cooling plate has extended cooling surfaces exposed in the cooling air flow channel. Thermal behavior of the battery system under a user specified electrical-load cycle for the target hybrid vehicle is characterized with the equivalent continuous load profile using a 3D finite element analysis (FEA) model for battery cooling. Analysis results are compared with measurements. Good agreement is observed between the simulated and measured cell temperatures. Improvement of the cooling system design is also studied with assistance of the battery cooling analyses.
Journal Article

An Analysis of a Lithium-ion Battery System with Indirect Air Cooling and Warm-Up

2011-09-13
2011-01-2249
Ideal operation temperatures for Li-ion batteries fall in a narrow range from 20°C to 40°C. If the cell operation temperatures are too high, active materials in the cells may become thermally unstable. If the temperatures are too low, the resistance to lithium-ion transport in the cells may become very high, limiting the electrochemical reactions. Good battery thermal management is crucial to both the battery performance and life. Characteristics of various battery thermal management systems are reviewed. Analyses show that the advantages of direct and indirect air cooling systems are their simplicity and capability of cooling the cells in a battery pack at ambient temperatures up to 40°C. However, the disadvantages are their poor control of the cell-to-cell differential temperatures in the pack and their capability to dissipate high cell generations.
Journal Article

A Thermodynamic Model for a Single Cylinder Engine with Its Intake/Exhaust Systems Simulating a Turbo-Charged V8 Diesel Engine

2011-04-12
2011-01-1149
In this paper, a thermodynamic model is discussed for a single cylinder diesel engine with its intake and exhaust systems simulating a turbo-charged V8 diesel engine. Following criteria are used in determination of the gas exchange systems of the single cylinder engine (SCE): 1) the level of pressure fluctuations in the intake and exhaust systems should be within the lower and upper bounds of those simulated by the thermodynamic model for the V8 engine and patterns of the pressure waves should be similar; 2) the intake and exhaust flows should be reasonably close to those of the V8 engine; 3) the cylinder pressures during the combustion and gas exchange should be reasonably close to those of the V8 engine under the same conditions for the valve timing, fuel injection, rate of heat release and in-cylinder heat transfer. The thermodynamic model for the SCE is developed using the 1D engine thermodynamic simulation tool AVL BOOST.
Journal Article

A Semi-Empirical Model for Predicting Pressure Drops of Fouled EGR Coolers

2010-10-05
2010-01-1948
The performance of an EGR cooler is influenced significantly by particulate fouling in the cooler. As a result of fouling, a highly porous soot deposit layer is formed in the EGR cooler. This deposit layer not only causes a decrease in the cooler effectiveness but also an increase in the EGR pressure drop over the cooler. Increasing the EGR cooler pressure drop reduces the driving force for the EGR flow under a given differential pressure across the engine. Thus, the EGR cooler fouling has a big impact on the control of the engine-out NO emissions. In this paper, a semi-empirical model is developed for predicting pressure drops of fouled EGR coolers. Based on this model and the particulate fouling model developed previously by the author, the process is analyzed for the pressure drop increase with building up of the soot deposit in an EGR cooler.
Technical Paper

A Rankine Cycle System for Recovering Waste Heat from HD Diesel Engines - WHR System Development

2011-04-12
2011-01-0311
Waste heat recovery (WHR) has been recognized as a promising technology to achieve the fuel economy and green house gas reduction goals for future heavy-duty (HD) truck diesel engines. A Rankine cycle system with ethanol as the working fluid was developed at AVL Powertrain Engineering, Inc. to investigate the fuel economy benefit from recovering waste heat from a 10.8L HD truck diesel engine. Thermodynamic analysis on this WHR system demonstrated that 5% fuel saving could be achievable. The fuel economy benefit can be further improved by optimizing the design of the WHR system components and through better utilization of the available engine waste heat. Although the WHR system was designed for a stand-alone system for the laboratory testing, all the heat exchangers were sized such that their heat transfer areas are equivalent to compact heat exchangers suitable for installation on a HD truck diesel engine.
Technical Paper

A Rankine Cycle System for Recovering Waste Heat from HD Diesel Engines - Experimental Results

2011-04-12
2011-01-1337
A Rankine cycle system with ethanol as the working fluid was developed to investigate the fuel economy benefit of recovering waste heat from a 10.8-liter heavy-duty (HD) truck diesel engine. Recovering rejected heat from a primary engine with a secondary bottoming cycle is a proven concept for improving the overall efficiency of the thermodynamic process. However, the application of waste heat recovery (WHR) technology to the HD diesel engine has proven to be challenging due to cost, complexity, packaging and control during transient operation. This paper discusses the methods and technical innovations required to achieve reliable high performance operation of the WHR system. The control techniques for maintaining optimum energy recovery while protecting the system components and working fluid are described. The experimental results are presented and demonstrate that 3-5% fuel saving is achievable by utilizing this technology.
Technical Paper

A Model-Based Analysis on Size Distribution and Rate of Evaporation for Fuel Drops in a Gasoline Spray in the Engine

2012-04-16
2012-01-1264
Good understanding of fuel sprays in the engine cylinder is crucial to optimizing the operation of direct injection gasoline engines. In this paper, a detailed analysis is conducted on direct gasoline injection sprays from a multi-hole injector. Penetrations and angles of the sprays are characterized with a homogeneous model for the fuel spray. The drop size distributions in the sprays are analyzed using an empirical distribution model. Predicted spray penetrations, spray angles, and drop size distributions under three different injection pressures are compared with the measurements for injection pressures = 40, 100 and 150 bar and good agreements are observed. Transient evaporation rates are also studied for fuel drops in an environment simulating the cylinder condition during the intake stroke of a direct injection gasoline engine.
X