Investigation of Failure Modes in the DEXRON® III-H GM Cycling and Oxidation Tests

2005-10-24
2005-01-3891
To develop an automatic transmission fluid (ATF) that meets DEXRON® III-H specifications, the ATF must pass two critical tests, the GM oxidation test (GMOT) and the GM cycling test (GMCT), in addition to many other performance tests. The specification on the GMOT is that delta TAN (difference in total acid number compared with the fresh oil) at the end of the test does not exceed 3.25 while the specifications on GMCT are that delta TAN cannot exceed 2.0 and the 1-2 shift time must stay between 0.30 and 0.75 seconds throughout the test. For this work, we analyze oil oxidation and changes in oils' surface tension, drum and band surface degradation and deposit formation. We have found that with respect to the delta TAN limits of the DEXRON® III-H specification, the GMCT is more severe than the GMOT. The effect of base oil chemistry on oxidation in these tests has been quantified. Oil oxidation is not responsible for the GMCT 1-2 shift time increase.