Technical Paper

Measurement and Intra-Layer Modeling of Soot Density and Permeability in Wall-flow Filters

2006-04-03
2006-01-0261
The objective of this study is to study the soot layer density and permeability in wall-flow diesel particulate filters. Knowledge of the soot morphology as function of the operating conditions is important for the design and on-board control of Diesel Particulate Filters (DPFs). The experimental set-up relies on a specially designed soot loading procedure on single-channel cordierite filters. The experimental conditions simulate real-world as close as possible regarding the filtration velocity, temperature and soot quality, since the sampling is done in real exhaust. By cutting, weighing and imaging the single channel filters it is possible to measure with accuracy the soot layer thickness as deposited under different operating conditions. Combined with pressure drop measurements and modeling, it is further possible to evaluate the soot layer permeability.