Technical Paper
Investigation of Ultrafine Particle Number Measurements from a Clean Diesel Truck Using the European PMP Protocol
2007-04-16
2007-01-1114
The sampling protocol proposed by the international PMP program for determination of particle emissions from clean light-duty vehicles was applied to the emissions from a California heavy-duty trap-equipped diesel truck. CARB is interested in developing opinions about the potential of this new European approach for emission determination and in exploring its utility for use in California. In this exercise, the use of various commercially available instruments for counting and sizing particles in the context of the PMP recommendations are explored. A single vehicle on a chassis dynamometer was exercised over steady-state and transient cycles. Multiple measurements of gaseous, mass, and particle emissions were collected in order to determine statistical significance. The PMP approach yielded particle emission measurements with higher precision and accuracy than the reference mass-based emission measurement.