Technical Paper

Transmission Modulating Valve Simulation and Simulation Verification

1990-04-01
900917
This paper presents a response to the question: Simulation - mathematical manipulation or useful design tool? A mathematical model of a modulating valve in a transmission control system was developed to predict clutch pressure modulation characteristics. The transmission control system was previously reported in SAE Paper 850783 - “Electronic/Hydraulic Transmission Control System for Off-Highway Vehicles”. The comparison of simulation predictions with test data illustrates the effectiveness of simulation as a design tool. THE EVOLUTION OF COMPUTER hardware and simulation software has resulted in increased interest and usage of simulation for dynamic analysis of hydraulic systems. Most commercially available software is relatively easy to learn to use. The application of such software and the modeling techniques involved require a longer learning curve.
Technical Paper

System Identification of an Electrohydraulic Steering System

1999-09-14
1999-01-2854
This paper presents system identification methods of using both frequency and time domain analyses to estimate system parameters for a nonlinear electrohydraulic (E/H) tractor steering system. The frequency domain method identified parameters of the system using a linear model with a nonlinear gain function. The time domain method identified those parameters using a discrete time expression. A method of multiple models was used to represent the nonlinear system for both frequency and time domain analyses. Simulation and test results showed that the modified identification method could satisfactorily identify the parameters of the nonlinear E/H tractor steering system.
Technical Paper

Strategies for Developing Performance Standards for Alternative Hydraulic Fluids

2000-09-11
2000-01-2540
There has been an ongoing interest in replacing mineral oil with more biodegradable and/or fire-resistant hydraulic fluids in many mobile equipment applications. Although many alternative fluids may be more biodegradable, or fire-resistant, or both than mineral oil, they often suffer from other limitations such as poorer wear, oxidative stability, and yellow metal corrosion which inhibit their performance in high-pressure hydraulic systems, particularly high pressure piston pump applications. From the fluid supplier's viewpoint, the development of a definitive test, or series of tests, that provides sufficient information to determine how a given fluid would perform with various hydraulic components would be of interest because it would minimize extensive testing. This is often too slow or prohibitively expensive. Furthermore, from OEM's (original equipment manufacturer's) point of view, it would be advantageous to develop a more effective, industry accepted fluid analysis screening.
Technical Paper

High Performance Biodegradable Fluid Requirements for Mobile Hydraulic Systems

1998-04-08
981518
Technical groups worldwide have been actively developing specifications and requirements for biodegradable hydraulic fluids for mobile applications. These groups have recognized that an industry-wide specification is necessary due to the increase in environmental awareness in the agriculture, construction, forestry, and mining industries, and to the increasing number of local regulations primarily throughout Europe. Caterpillar has responded to this need by publishing a requirement, Caterpillar BF-1, that may be used by Caterpillar dealers, customers, and industry to help select high-performance biodegradable hydraulic fluids. This requirement was written with the input of several organizations that are known to be involved with the development of similar types of specifications and requirements.
Technical Paper

Dynamic Model of a Springless Electrohydraulic Valvetrain

1997-02-24
970248
A dynamic model for the springless electrohydraulic valvetrain has been developed. The model speeds up the valvetrain development process by simulating effects of parameter changes, thus minimizing the number of hardware variations. It includes dynamic characteristics of check valves that enable energy recovery, hydraulic snubbers that limit seating velocity of the engine valves, and leakage in the control solenoids. A good match of the experimental data has been obtained for a single valve system, and the model calibration and validation have been completed. The known parameters are used together with some unknown calibration constants which have been tuned to match the experimental data. The simulation results for a twin valve system are also presented. The model applications for system performance analysis and for the closed-loop control of the engine valve lift are described. The cyclic variability of the experimental data is also discussed.
Technical Paper

Development of the Hydraulic System for the Caterpillar 416 Backhoe Loader

1986-09-01
861290
A key ingredient in the development of the Caterpillar 416 backhoe loader was the development of the hydraulic system. A load sensing, pressure compensated system was selected on the basis of its best being able to meet design goals. The result is a backhoe loader in which the hydraulic system contributes greatly to the vehicle's overall acceptance by operating efficiently and utilizing low lever efforts for ease of control.
Technical Paper

Computational Fluid Dynamics (CFD) Analysis to Predict and Control the Cavitation Erosion in a Hydraulic Control Valve

2002-03-04
2002-01-0572
This paper summarizes the successful application of Computational Fluid Dynamics (CFD) analysis to predict and control the cavitation erosion in a hydraulic control valve. The accurate control of different vehicle operations demands very fine spool modulations in a hydraulic valve. The precise spool modulations create very high flow rates and high-pressure drops in the valve. The low local fluid pressure regions create cavitation inside the valve. Due to the explosion of bubbles there is a high erosion damage to the valve body as well as the spool surface. The CFD analysis has been used to predict the location of cavitation origination and also used to control the cavitation by redistributing the flow inside the valve.
Technical Paper

Biodegradable Hydraulic Fluids: A Review

1999-09-14
1999-01-2865
There is an ongoing interest in biodegradable hydraulic fluids. Biodegradable fluids are often considered to include only vegetable oils, polyol esters and diester base stocks. However, other fluid base stocks including highly refined mineral oils, poly(alpha olefins) and fire-resistant fluids such as water-glycol hydraulic fluids are also biodegradable fluid alternatives. This paper will provide an overview of the international literature on biodegradable fluids, various international testing protocol, fluid base stocks, effect of oxidative stability, material compatibility and pump performance.
Technical Paper

Automated Guidance Control for Agricultural Tractor Using Redundant Sensors

1999-04-14
1999-01-1874
The development of automated guidance for agricultural tractors has addressed several basic and applied issues of agricultural equipment automation. Basic analyses have included the dynamics of steering systems and posture sensors for guidance. Applied issues have evaluated the potential of several commercial sensing systems and a commercial mechanical guidance system. A research platform has been developed based on a Case 7220 Magnum1 2-wheel drive agricultural tractor. An electrohydraulic steering system was used and characterized in support of automated guidance control. Posture sensing methods were developed using GPS, geomagnetic direction sensors (GDS), inertial, and machine vision sensing systems. Sensor fusion of GPS-inertial-machine vision and GPS-GDS-machine vision provided the most flexible and accurate guidance and capable for operation under dynamically changing field conditions.
Technical Paper

Adaptive Lift Control for a Camless Electrohydraulic Valvetrain

1998-02-23
981029
Camless actuation offers programmable flexibility in controlling engine valve events. However, a full range of engine benefits will only be available, if the actuation system can control lift profile characteristics within a particular lift event. Control of the peak value of valve lift is a first step in controlling the profile. The paper presents an adaptive feedback control of valve lift for a springless electrohydraulic valvetrain. The adaptive control maintains peak value of lift in presence of variations in engine speed, hydraulic fluid temperature and manufacturing variability of valve assemblies. The control design includes a reduced-order model of the system dynamics. Experimental results show dynamic behavior under various operating and environmental conditions and demonstrate advantages of adaptive control over the non-adaptive type.