Technical Paper
Hybrid III Dummy Neck Issues
2005-04-11
2005-01-1704
While the Hybrid III anthropomorphic test device (ATD) family has experienced a lengthy period of development, and is an essential part of vehicle safety regulation, several issues associated with the ATD's head/neck design and the neck dynamic response due to airbag loading have been identified. As a result, the response of the Hybrid III neck under a number of airbag loading conditions could be an “artifact” of the ATD and not representative of the live human. One area of concern relates to the method of incorporating the human neck muscles into the neck response and how this affects the out-of-position (OOP) tests mandated in the new FMVSS 208. The results of a series of sled and OOP tests are presented in this paper to elaborate on the nature and the magnitude of the ATD's neck response “artifact”. In addition, the complication associated with balancing in-position and OOP requirements as a result of this “artifact” is highlighted.