Refine Your Search

Search Results

Viewing 1 of 1
Technical Paper

Characterization of Microbial Contamination in Pretreated Urine Collected from the ISS Urine Processing Assembly during Ground Testing

2009-07-12
2009-01-2421
With the installation of the Water Recovery System (WRS) during mission STS-126 in 2008, the International Space Station (ISS) added the capability to recover clean water for reuse from crewmember urine and atmospheric humidity condensate, including EVA (Extravehicular Activity) wastes. The ability to collect, store and process these waste streams is required to increase potable water recovery and support the ISS crew augmentation planned for 2009. During ground testing of the Urine Processing Assembly (UPA), one of two primary component subsystems that comprise the WRS, significant fouling was repeatedly observed in stored urine pretreated with 0.56% of chromium trioxide and sulfuric acid. During initial observation, presumptive microbiological growth clogged and damaged flight-rated hardware under test as part of a risk-mitigation Flight Experiment (FE).