Refine Your Search

Topic

Search Results

Viewing 1 to 10 of 10
Technical Paper

Thermal Testing of a Heat Switch for European Mars Rover

2009-07-12
2009-01-2573
A Heat Switch has been developed, namely a device able to autonomously regulate its own thermal conductance in function of the equipment dissipation and environmental heat sink conditions. It is based on a Loop Heat Pipe (LHP) technology, with a passive bypass valve which diverts the flow to the Compensation Chamber when needed for regulation purposes. The target application is the potential use on a Mars Rover thermal control system. The paper recalls the Heat Switch design, and reports the results of an extensive test campaign on the ground demonstrator. The performance of the device was found extremely satisfying, and often exceeded the system requirements.
Technical Paper

Thermal Control Architecture of the Automated Transfer Vehicle

1998-07-13
981778
The Automated Transfer Vehicle (ATV) is a European Space Agency autonomous, expendable logistic transportation system for Low Earth Orbit. The ATV will be launched by Ariane 5 and its mission is to contribute to the logistic servicing of the International Space Station: via the delivery of a cargo (crew items, scientific experiments, spare parts..) as well as of fluids such as propellant, water and compressed air via the provision of an extra service consisting of retrieving the station wastes when departing (replacing the upcoming cargo) and getting rid of them through the final destructive atmospheric re-entry of the ATV itself via the contribution to the orbit control of ISS by providing a reboost and attitude control capability to the ISS. The ATV consists of a Spacecraft and an Integrated Cargo Carrier. The Spacecraft includes all subsystems necessary for the automated flight to the ISS and for the reboost, including the propellant tanks and the thrusters.
Technical Paper

Results of Breadboard Tests Withan Integrated CO2, Humidity and Thermal Control System

2003-07-07
2003-01-2348
Membrane gas absorption and desorption (MGA/MGD) for the removal of CO2 in manned spacecraft or other enclosed environment is subject of study by Stork and TNO for many years. The system is based on the combination of membrane separation and gas absorption. Advantage of this technology is that the system not only can be used to remove the carbon dioxide but also to control the relative humidity and temperature. Absorption of moisture and heat is achieved by cooling the absorption liquid below the dewpoint temperature of the gas stream. From the start in 1995, the Crew Transfer Vehicle is used as a basis for the design (1,2). Compared to the planned air conditioning system, consisting of a condensing heat exchanger, LiOH cartridges and a water evaporator assembly, MGA/MGD shows advantage in volume, mass and power consumption. The absorption liquid circulates through the spacecraft thermal control loop, replacing the coolant water.
Technical Paper

MELISSA: Current Status and Future Development Program

1993-07-01
932126
The MELISSA (Microbial Ecological LIfe Support System Alternative) project has been set up to be a model for the studies on ecological life support systems for long term space missions. The compartmentalisation of the loop, the choice of the micro-organisms and the axenic conditions have been selected in order to simplify the behaviour of this artificial ecosystem and allow a deterministic and engineering approach. In this framework the MELISSA project has now been running since beginning 1989. In this paper we present the general approach of the study, the scientific results obtained on each independent compartment (mass balance, growth kinetics, limitations, compound conversions,..), the tests of toxicity already performed between some compartments and their effect on the growth kinetics. The technical results on instrumentation and control aspects, and the current status of the ESA/ESTEC hardware are also reviewed.
Technical Paper

MELFI Cooling Performance Characterization and Verification

2000-07-10
2000-01-2308
The Minus Eighty (Degrees Celsius) Laboratory Freezer for the International Space Station (MELFI) is one of the freezers developed by ESA on behalf of NASA. Peculiar requirements for that facility are the long-term storage at low temperature, the rapid freezing of specimen to the required temperature, the large cold volume (300 l) and the low power consumption. To verify those requirements before the manufacturing of the flight hardware, a dedicated test campaign was performed on a ground model. This paper will start with a system overview, showing the main features of MELFI. The test set-up as well as their results will be presented and discussed, with particular emphasis on the methods used to predict the on-orbit (0-gravity) behaviour, by avoiding the sample internal convection and dewar internal convection during the test execution.
Technical Paper

Integrated CO2 and Humidity Control by Membrane Gas Absorption

1997-07-14
972560
In a harmonized ESA/NIVR project the performance of membrane gas absorption for the simultaneous removal of carbon dioxide and moisture has been determined experimentally at carbon dioxide and humidity concentration levels representative for spacecraft conditions. Performance data at several experimental conditions have been collected. Removal of moisture can be controlled by the temperature of the absorption liquid. Removal of carbon dioxide is slightly affected by the temperature of the absorption liquid. Based on these measurements a conceptual design for a carbon dioxide and humidity control system for the Crew Transport Vehicle (CTV) is made. For the regeneration step in this design a number of assumptions have been made. The multifunctionality of membrane gas absorption makes it possible to combine a number of functions in one compact system.
Technical Paper

Improving the Columbus Integrated Overall Thermal Mathematical Model (IOTMM) Using Computational Fluid Dynamics (CFD)

2005-07-11
2005-01-2796
The cabin space of the Columbus APM is well ventilated by air entering through multiple air diffusers and exiting via the return grid and hatch. Therefore, the heat transfers by bulk fluid motion and by convection to the walls need to be experimentally and/or numerically investigated and implemented in the thermal mathematical models (TMM) describing the cabin. CFD analysis provided key data on the thermal couplings due to convective heat transfer and bulk fluid motion for the thermal mathematical model, which in turn was used to correlate test data from an environmental control system test and to provide supplemental information on assumptions used in the lumped capacitance model. This paper presents the logic and results of the steady-state CFD analysis, the potential implementation of the results in a thermal mathematical model, and compares these results with test data obtained during a separate Columbus cabin ventilation qualification test.
Technical Paper

First Use of ECOSIM in Air Management Systems

1992-07-01
921292
ECOSIM is a software tool for the simulation of Environmental Control and Life Support (ECLS) systems which has been developed for the European Space Agency. A preliminary model of the Hermes Air Management System has been developed during the ECOSIM testing in order to assess the functionality of the software and to verify its results with those obtained from previous simulation tools. The model represents the Hermes cabin with its crew and it includes submodels for the sub-systems performing the following functions: Temperature and Humidity Control. Total Pressure and Composition Control. Air revitalisation. The interactions between these different subsystem are taken into account by the model, while many of the previous simulations made assumptions to decouple the different subsystems (e.g: a constant cabin temperature has been assumed during cabin depressurization transients, to decouple the pressure control section from the air conditioning section).
Technical Paper

Design and Qualification of Methane Filled Heat Pipes for the SCIAMACHY Radiant Cooler

1997-07-01
972451
Methane-filled heat pipes have been developed and qualified for the SCIAMACHY thermal bus assembly. The heat pipes provide an efficient heat transfer in the temperature range 100-160 K. Extensive qualification testing has been performed. The thermal bus assembly is part of the Thermal Bus Unit (TBU) of the SCIAMACHY Radiant Cooler.
Technical Paper

Columbus Launch Preparation - Final System ATCS Tests Summary and Lessons Learned

2008-06-29
2008-01-2033
Final preparation and configuration of the Columbus module at the Kennedy Space Center (KSC) required the performance of system level tests with the Active Thermal Control System (ATCS). These tests represented the very last system level activities having been concluded on the Columbus module before handover to NASA for space shuttle integration. Those very last tests, performed with the ATCS comprised the final ATCS Leakage Test, the final calibration and adjustment of the Water Flow Selection Valves (WFSV) and Water On/Off Valves (WOOV) as well as a sophisticated ATCS Residual Air Removal test. The above listed tests have been successfully performed and test data evaluated for verification closeout as well as input delivery for operational Flight Rules and Procedures. Some of the above mentioned tests have been performed the first time hence, a succeeding lessons learned collection followed in order to improve the perspectives of future tests.
X