Refine Your Search

Topic

Author

Search Results

Technical Paper

Viral Populations within the International Space Station's Internal Active Thermal Control System Ground Support and Potential Flight Hardware

2007-07-09
2007-01-3108
The Internal Active Thermal Control System (IATCS) aboard the International Space Station (ISS) contains an aqueous, alkaline fluid (pH 9.5±0.5) that aids in maintaining a habitable environment for the crew. Because microbes have significant potential to cause disease, adverse effects on astronaut health, and microbe-induced corrosion, the presence of both bacteria and viruses within IATCS fluids is of concern. This study sought to detect and identify viral populations in IATCS samples obtained from the Kennedy Space Center as a first step towards characterizing and understanding potential risks associated with them. Samples were concentrated and viral nucleic acids (NA) extracted providing solutions containing 8.87-22.67 μg NA per mL of heat transfer fluid. After further amplification viral DNA and cDNA were then pooled, fluorescently labeled, and hybridized onto a Combimatrix panvira 12K microarray containing probes for ∼1,000 known human viruses.
Technical Paper

Trace Gas Analyzer for Extra-Vehicular Activity

2001-07-09
2001-01-2405
The Trace Gas Analyzer (TGA, Figure 1) is a self-contained, battery-powered mass spectrometer that is designed for use by astronauts during extravehicular activities (EVA) on the International Space Station (ISS). The TGA contains a miniature quadrupole mass spectrometer array (QMSA) that determines the partial pressures of ammonia, hydrazines, nitrogen, and oxygen. The QMSA ionizes the ambient gas mixture and analyzes the component species according to their charge-to-mass ratio. The QMSA and its electronics were designed, developed, and tested by the Jet Propulsion Laboratory (1,2). Oceaneering Space Systems supported JPL in QMSA detector development by performing 3D computer for optimal volumetric integration, and by performing stress and thermal analyses to parameterize environmental performance.
Technical Paper

Toward A Second Generation Electronic Nose at JPL: Sensing Film Optimization Studies

2001-07-09
2001-01-2308
Development of a second generation Electronic Nose at JPL is focusing on optimization of the sensing films to increase sensitivity and optimization of the array. Toward this goal, studies have focused on sources of noise in the films, alternatives to carbon black as conductive medium, measurement techniques, and development of an analytical approach to polymer selection to maximize the abilities of the array to distinguish among compounds.
Technical Paper

Thermal Vacuum Testing of the Orbiting Carbon Observatory Instrument

2008-06-29
2008-01-2036
The Orbiting Carbon Observatory (OCO) instrument is scheduled for launch onboard an Orbital Sciences Corporation LEOStar-2 architecture spacecraft in December 2008. The instrument will collect data to identify CO2 sources and sinks and quantify their seasonal variability. OCO observations will permit the collection of spatially resolved, high resolution spectroscopic observations of CO2 and O2 absorption in reflected sunlight over both continents and oceans. OCO has three bore-sighted, high resolution, grating spectrometers which share a common telescope with similar optics and electronics. A 0.765 μm channel will be used for O2 observations, while the weak and strong CO2 bands will be observed with 1.61 μm and 2.06 μm channels, respectively. The OCO spacecraft circular polar orbit will be sun-synchronous with an inclination of 98.2 degrees, mean altitude of 705 km and 98.9 minute orbit period.
Technical Paper

Thermal Performance Evaluation of a Small Loop Heat Pipe for Space Applications

2003-07-07
2003-01-2688
A Small Loop Heat Pipe (SLHP) featuring a wick of only 1.27 cm (0.5 inches) in diameter has been designed for use in spacecraft thermal control. It has several features to accommodate a wide range of environmental conditions in both operating and non-operating states. These include flexible transport lines to facilitate hardware integration, a radiator capable of sustaining over 100 freeze-thaw cycles using ammonia as a working fluid and a structural integrity to sustain acceleration loads up to 30 g. The small LHP has a maximum heat transport capacity of 120 Watts with thermal conductance ranging from 17 to 21 W/°C. The design incorporates heaters on the compensation chamber to modulate the heat transport from full-on to full-stop conditions. A set of start up heaters are attached to the evaporator body using a specially designed fin to assist the LHP in starting up when it is connected to a large thermal mass.
Technical Paper

Thermal Control of Mars Lander and Rover Batteries and Electronics Using Loop Heat Pipe and Phase Change Material Thermal Storage Technologies

2000-07-10
2000-01-2403
This paper describes a novel thermal control system for future Mars landers and rovers designed to keep battery temperatures within the −10 °C to +25 °C temperature range. To keep the battery temperatures above the lower limit, the system uses: 1) a phase change material (PCM) thermal storage module to store and release heat and 2) a loop heat pipe (LHP) to transfer heat from a set of Radioisotope Heater Units (RHUs) to the battery. To keep the battery temperature below the upper limit, a thermal control valve in the LHP opens to redirect the working fluid to an external radiator where excess heat is dumped to the atmosphere. The PCM thermal storage module was designed and fabricated using dodecane paraffin wax (melting point, − 9.6 °C) as the phase change material. A miniature ammonia loop heat pipe with two condensers and an integrated thermal control valve was designed and fabricated for use with the PCM thermal storage unit.
Technical Paper

Slow Reversible and Quasi-Reversible Performance Changes in AMTEC Electrodes and Electrolytes

1999-08-02
1999-01-2705
This paper reports several slow reversible and quasi-reversible processes which occur in the porous electrode/solid electrolyte combination at AMTEC operating temperatures. These processes help to elucidate the evolution of the electrode and electrolyte characteristics with time. They also demonstrate that the atomic constituents of the electrode/electrolyte engage in significant dynamic motion. We report the stability of the sodium beta“-alumina phase in low pressure sodium vapor at 1173K up to 3000 hours, and the decomposition of the sodium meta-aluminate (NaAlO2) phase present at about 1% in the BASE ceramic, which gives rise to transient local increases in the solid electrolyte resistivity due to local micro-cracking. We also report slow apparent morphological changes, possibly surface or grain boundary reconstruction, in TiN and RhW electrodes driven by changes in the local sodium activity.
Technical Paper

Self-Sterilizing Properties of Martian Soil: Possible Nature & Implications

2000-07-10
2000-01-2343
As a result of the Viking missions in 1970s, the presence of a strong oxidant in Martian soil was suggested. Here we present a testable, by near-term missions, hypothesis that iron(VI) contributes to that oxidizing pool. Ferrate(VI) salts were studied for their spectral and oxidative properties and biological activities. Ferrate(VI) has distinctive spectroscopic features making it available for detection by remote sensing reflectance spectra and contact measurements via Mössbauer spectroscopy. The relevant miniaturized instrumentation has been developed or is underway, while XANES spectroscopy is shown to be a method of choice for the returned samples. Ferrate(VI) is capable of splitting water to yield oxygen, and oxidizing organic carbon to CO2. Organic oxidation was strongly abated after pre-heating ferrate, similar to the observations with Mars soil samples.
Technical Paper

Self-Deployable Foam Antenna Structures for Earth Observation Radiometer Applications

2006-07-17
2006-01-2064
The overall goal of this program was the development of a 10 m. diameter, self-deployable antenna based on an open-celled rigid polyurethane foam system. Advantages of such a system relative to current inflatable or self-deploying systems include high volumetric efficiency of packing, high restoring force, low (or no) outgassing, low thermal conductivity, high dynamic damping, mechanical isotropy, infinite shelf life, and easy fabrication with methods amenable to construction of large structures (i.e., spraying). As part of a NASA Phase II SBIR, Adherent Technologies and its research partners, Temeku Technologies, and NASA JPL/Caltech, conducted activities in foam formulation, interdisciplinary analysis, and RF testing to assess the viability of using open cell polyurethane foams for self-deploying antenna applications.
Technical Paper

Results from the Vehicle Cabin Atmosphere Monitor: A Miniature Gas Chromatograph/Mass Spectrometer for Trace Contamination Monitoring on the ISS and Orion

2008-01-29
2008-01-2045
Progress on the delivery of the Vehicle Cabin Atmosphere Monitor (VCAM) is reported. VCAM is an autonomous trace-species detector to be used aboard the International Space Station (ISS) for atmospheric analysis. The instrument is based on a low-mass, low-power miniature preconcentrator, gas chromatograph, and Paul ion trap mass spectrometer (PCGC/MS) capable of measuring volatile constituents in a space vehicle or planetary outpost at sub-ppm levels. VCAM detects and quantifies 40 target compounds at their 180-day Spacecraft Maximum Allowable Concentration (SMAC) levels. It is designed to operate autonomously, maintenance-free, with a self-contained carrier and calibration gas supplies sufficient for a one-year lifetime. Two flight units will be delivered for operation in the ISS EXPRESS rack.
Technical Paper

Performance Characteristics of Lithium-Ion Cells for NASA’s Mars 2001 Lander Application

1999-08-02
1999-01-2638
NASA requires lightweight rechargeable batteries for future missions to Mars and the outer planets that are capable of operating over a wide range of temperatures, with high specific energy and energy densities. Due to the attractive performance characteristics, lithium-ion batteries have been identified as the battery chemistry of choice for a number of future applications, including Mars rovers and landers. The Mars 2001 Lander (Mars Surveyor Program MSP 01) will be among one of the first missions which will utilize lithium-ion technology. This application will require two lithium-ion batteries, each being 28 V (eight cells), 25 Ah and 8 kg. In addition to the requirement of being able to supply at least 200 cycles and 90 days of operation upon the surface of Mars, the battery must be capable of operation (both charge and discharge) at temperatures as low as -20°C.
Technical Paper

Performance Characteristics of Lithium-Ion Cells for Mars Sample Return Athena Rover

1999-08-02
1999-01-2639
In contrast to the primary batteries (lithium thionyl chloride) on the Sojourner Mars Rover and the upcoming 2001 Mars Rover, the Mars Sample Return (MSR) Athena Rover will utilize rechargeable lithium ion batteries, following the footsteps of MSP 2001 Lander. The MSR Athena Rover will contain a rechargeable lithium ion battery of 16 V and a total energy of 150 Wh. The mass and volume of the projected power system will be a maximum of 3 kg and 2 liters, respectively. Each battery consists of twelve cells (6-7 Ah), combined in three parallel strings of four cells (16 V) each, such that the capability of the Rover shall be maintained even in the event of one string failure. In addition to usual requirements of high specific energy and energy density and long cycle life (100 cycles), the battery is required to operate at wide range of temperatures, especially at sub-zero temperatures down to -20°C.
Technical Paper

Overview of the Vehicle Cabin Atmosphere Monitor, a Miniature Gas Chromatograph/Mass Spectrometer for Trace Contamination Monitoring on the ISS and CEV

2007-07-09
2007-01-3150
Work is underway to deliver an instrument for analysis of the atmosphere aboard the International Space Station. The Vehicle Cabin Atmosphere Monitor (VCAM) is based on a low-mass, low-power miniature preconcentrator gas chromatograph/mass spectrometer (PCGC/MS) capable of providing sub-ppm measurements of volatile constituents in a space vehicle or outpost. VCAM is designed to operate autonomously, maintenance-free, once per day, with its own carrier and calibration gas supplies sufficient for a one-year lifetime. VCAM performance is sufficient to detect and identify 90% of the target compounds specified at their 180-day Spacecraft Maximum Allowable Concentration (SMAC) levels. The flight units will be delivered in mid-2008 and be operated in the ISS EXPRESS rack.
Technical Paper

Operation of an Electronic Nose Aboard the Space Shuttle and Directions for Research for a Second Generation Device

2000-07-10
2000-01-2512
A flight experiment to test the operation of an Electronic Nose developed and built at JPL and Caltech was done aboard STS-95 in October-November, 1998. This ENose uses conductometric sensors made of insulating polymer-carbon composite films; it has a volume of 1.7 liters, weighs 1.4 kg including the operating computer and operates on 1.5 W average power. In the flight experiment, the ENose was operated continuously for 6 days and recorded the sensors' response to changes in air in the mid-deck of the orbiter. The ENose had been trained to identify and quantify ten common contaminants at the 24-hour Spacecraft Maximum Allowable Concentration (SMAC) level. Most SMACs are on the order of 10-100 ppm. The experiment was controlled by collecting air samples daily and analyzing them using standard analytical techniques after the flight. The device is microgravity insensitive.
Technical Paper

On-Orbit Performance of the TES Loop Heat Pipe Heat Rejection System

2008-06-29
2008-01-2000
Launched on NASA's Aura spacecraft on July 15, 2004, JPL's Tropospheric Emission Spectrometer (TES) has been operating successfully for over three years in space. TES is an infrared high resolution, imaging fourier transform spectrometer with spectral coverage of 3.3 to 15.4 μm to measure and profile essentially all infrared-active molecules present in the Earth's lower atmosphere. It measures the three-dimensional distribution of ozone and its precursors in the lower atmosphere on a global scale. The Aura spacecraft was successfully placed in a sun-synchronous near-circular polar orbit with a mean altitude of 705 km and 98.9 minute orbit period. The observatory is designed for a nominal 5 year mission lifetime. The instrument thermal design features include four temperature zones needed for efficient cryogenic staging to provide cooling at 65 K, 180 K, 230 K and 300 K.
Journal Article

Off-Gassing and Particle Release by Heated Polymeric Materials

2008-06-29
2008-01-2090
Polymers are one of the major constituents in electrical components. A study investigating pre-combustion off-gassing and particle release by polymeric materials over a range of temperatures can provide an understanding of thermal degradation prior to failure which may result in a fire hazard. In this work, we report simultaneous measurements of pre-combustion vapor and particle release by heated polymeric materials. The polymer materials considered for the current study are silicone and Kapton. The polymer samples were heated over the range 20 to 400°C. Response to vapor releases were recorded using the JPL Electronic Nose (ENose) and Industrial Scientific's ITX gas monitor configured to detect hydrogen chloride (HCl), carbon monoxide (CO) and hydrogen cyanide (HCN). Particle release was monitored using a TSI P-TRAK particle counter.
Technical Paper

Monitoring Pre-Combustion Event Markers by Heating Electrical Wires

2009-07-12
2009-01-2543
Simultaneous measurements were made for particle releases and off-gassing products produced by heating electrical wires. The wire samples in these experiments were heated to selected temperatures in a heating chamber and responses to vapor releases were recorded by the JPL Electronic Nose (ENose) and an Industrial Scientific ITX gas-monitor; particles released were detected by a TSI P-Trak particle counter. The temperature range considered for the experiment is room temperature (24−26°C) to 500 °C. The results were analyzed by overlapping responses from the ENose, ITX gas sensors and P-Trak, to understand the events (particle release/off-gassing) and sequence of events as a function of temperature and to determine qualitatively whether ENose may be used to detect pre-combustion event markers.
Technical Paper

Model for Grain Growth in AMTEC Electrodes

1999-08-02
1999-01-2703
The power produced by an AMTEC is dependent on the porosity of the electrode layers deposited on the surface of the BASE tubes. The elevated temperatures at which these power generators operate result in a slow growth or coalescence of the grains that comprise the electrode layers thereby reducing porosity and effective surface area. The lifetime of AMTEC electrodes is therefore related to the rate of grain growth of the electrode material. A preliminary model has been developed to determine the rate of grain growth over the operational lifetime of an AMTEC. This model examines the conditions for continuous growth as a function of the relative sizes, boundary and activation energies and mobilities of the grains. An assumption of strain-free growth has been made in determining the factors for normal growth. Experimental measurements for titanium nitride alloy electrodes are compared with this model. Predictions are made for performance lifetimes out to 10 years.
Technical Paper

Mid-IR Semiconductor Lasers for Chemical Sensing

2003-07-07
2003-01-2551
The development of mid-IR semiconductor diode lasers based on type-II interband cascade structures is presented. How these diode lasers can be developed to meet the requirements in chemical sensing applications is discussed.
Technical Paper

Mechanically Pumped Fluid Loop Technologies for Thermal Control of Future Mars Rovers

2006-07-17
2006-01-2035
Future planetary science missions planned for Mars are expected to be more complex and thermally challenging than any of the previous missions. For future rovers, the operational parameters such as landing site latitudes, mission life, distance traversed, and rover thermal energy to be managed will be significantly higher (two to five times) than the previous missions. It is a very challenging problem to provide an effective thermal control for the future rovers using traditional passive thermal control technologies. Recent investigations at the Jet Propulsion Laboratory (JPL) have shown that mechanical pump based fluid loops provide a robust and effective thermal control system needed for these future rovers. Mechanical pump based fluid loop (MPFL) technologies are currently being developed at JPL for use on such rovers. These fluid loops are planned for use during spacecraft cruise from earth to Mars and also on the Martian surface operations.
X