Technical Paper

Cycle-Driven Optimization of a Fixed-Structure Controller for Urea Dosing in a Mobile SCR System

2020-11-04
2020-01-5106
A model-based urea-dosing controller has been developed for the selective catalytic reduction (SCR) units on a diesel engine exhaust aftertreatment system (EATS). The SCR units consist of an integrated SCR-coated filter and then followed by a flow-through SCR catalyst. The controller was developed based on an analysis of the data generated from a Millbrook London Transport Bus (MLTB) test cycle fed into a validated model of the SCR-filter and SCR units. The critical system parameters that showed strong correlation with outlet nitrogen oxides (NOx) and ammonia (NH3) emissions were first identified, and then the sensitivity of those parameters was analyzed. The most sensitive system parameters were configured as the controller gain parameters. A proportional controller based on the key parameters with optimized gains settings for the MLTB cycle delivered over a 10% reduction in cumulative NOx emission over the cycle compared to a fixed NH3/NOx ratio (ANR) controller.
Technical Paper

A Low Order Model of SCR-in-DPF Systems with Proper Orthogonal Decomposition

2018-04-03
2018-01-0953
This paper presents a method to achieve a low order system model of the urea-based SCR catalyst coated filter (SCR-in-DPF or SCRF or SDPF), while preserving a high degree of fidelity. Proper orthogonal decomposition (POD), also known as principal component analysis (PCA), or Karhunen-Loéve decomposition (KLD), is a statistical method which achieves model order reduction by extracting the dominant characteristic modes of the system and devises a low-dimensional approximation on that basis. The motivation for using the POD approach is that the low-order model directly derives from the high-fidelity model (or experimental data) thereby retains the physics of the system. POD, with Galerkin projection, is applied to the 1D + 1D SCR-in-DPF model using ammonia surface coverage and wall temperature as the dominant system states to achieve model order reduction.
X