Refine Your Search

Search Results

Viewing 1 to 2 of 2
Technical Paper

Experimental Analysis of Prominent Factors Affecting Evaporator Frosting in a Mobile Air-Conditioning (MAC) System

2020-08-18
2020-28-0014
In an automotive air conditioning system, evaporator is well designed for effective heat transfer between refrigerant and air flowing over the evaporator. This cold and dehumidified air obtained at evaporator is then supplied to passenger cabin. There are various parameters like air flow over evaporator, ambient temperature, humidity condition and condensate drain mechanism which can cause frost formation over the evaporator core. This study presents the probable causes of frost formation and their effects on the performance of evaporator and thus affecting overall performances of the automotive air conditioning system. In this study effect of variation in four major independent factors such as poor response of thermistor, undercharged refrigerant system and overcharged refrigerant system, drop in air flow by blower due to clogged air-filter, and also the effect of type of compressor has been studied.
Technical Paper

Experimental Analysis of HVAC System Level Noise in Mobile Air-Conditioning (MAC) System

2020-08-18
2020-28-0035
With the advent of new technologies and rigorous research and development work going on vehicle engines, cars are becoming quieter and more refined than ever before. This has led to the observance of subjective noises being audible to passenger compartment which were earlier masked behind engine noise. The vehicle HVAC system has several moving parts and transient flow of refrigerant which can cause certain types of irritant noise. Thus having a refinement in of air-conditioning (AC) system would aid us in cutting down on this parasitic noise source. Thus noise refinement should be one of the important parameters during the design and development of the Heating, Ventilation and Air-Conditioning (HVAC) system for a vehicle program.
X