Refine Your Search

Search Results

Viewing 1 of 1
Technical Paper

U.S. Lab-A Module Cabin Air Distribution in Space Station

1993-07-01
932192
This paper presents the basic test data obtained from tests of a cabin air distribution system in a simulated Space Station U.S. Lab-A module. The cabin air distribution system controls the flow of air in the open space of a Space Station module. In order to meet crew comfort criteria the local velocities for this cabin air are required to be distributed within a specified range with upper and lower limits. Achieving this desired velocity distribution is dependent upon the: (1.) design of the cabin air supply equipment and cabin air return equipment, (2.) total flowrate of air supplied to and subsequently returned from the cabin, and (3.) interactive effects of any other additional air flow streams which enter and exit the cabin. The basic Space Station design for the cabin air supply and air return equipment was used in this test program. Only directional adjustments to vanes in supply air diffusers were made during the test.