The purpose of this SAE Recommended Practice is to establish guidelines for the automatic transmission and hydraulic systems Engineer to design rectangular cross section seals for rotating and static grooved shaft applications. Also included are material property comparisons of polymeric materials suitable for these applications. Material covered in this document is not intended to include aluminum applications.
The purpose of this SAE Recommended Practice is to establish guidelines for the automatic transmission and hydraulic systems engineer to design rectangular cross section seals for rotating and static grooved shaft applications. Also included are property comparisons of polymeric materials suitable for these applications. Historically, material covered in this document is not intended to include aluminum contact applications.
The purpose of this SAE Recommended Practice is to establish guidelines for the automatic transmission and hydraulic systems engineer to design rectangular cross section seals for rotating and static grooved shaft applications. Also included are property comparisons of polymeric materials suitable for these applications. Historically, material covered in this document is not intended to include aluminum contact applications.
Since the torque converter and fluid coupling are commonly used components of automatic transmissions in industry, the SAE appointed a committee to standardize terminology, test procedure, data recording, design symbols, and so forth, in this field. The following committee recommendations will facilitate a clear understanding for engineering discussions, comparisons, and the preparation of technical papers. The recommended usages represent the predominant practice or the acceptable practice. Where agreement is not complete, alternates have been included for clarification. This SAE Recommended Practice deals only with the physical parts and dimensions and does not attempt to standardize the design considerations, such as the actual fluid flow angle resulting from the physical blade shape.
Since the torque converter and fluid coupling are commonly used components of automatic transmissions in industry, the SAE appointed a committee to standardize terminology, test procedure, data recording, design symbols, and so forth, in this field. The following committee recommendations will facilitate a clear understanding for engineering discussions, comparisons, and the preparation of technical papers. The recommended usages represent the predominant practice or the acceptable practice. Where agreement is not complete, alternates have been included for clarification. EXAMPLE: Two systems of blade angle designations are described. Consequently, when a blade angle is specified, the system should be designated. This SAE Recommended Practice deals only with the physical parts and dimensions and does not attempt to standardize the design considerations, such as the actual fluid flow angle resulting from the physical blade shape.
Since the torque converter and fluid coupling have become commonly used components of automatic transmissions in industry, the SAE appointed a committee to standardize terminology, test procedure, data recording, design symbols, and so forth, in this field. The following committee recommendations will facilitate a clear understanding for engineering discussions, comparisons, and the preparation of technical papers. The recommended usages represent the predominant practice or the acceptable practice. Where agreement is not complete, alternates have been included for clarification. This SAE Recommended Practice deals only with the physical parts and dimensions and does not attempt to standardize the design considerations, such as the actual fluid flow angle resulting from the physical blade shape.
The range of test conditions on the dynamometer shall be sufficient to determine the primary operating characteristics corresponding to the full range of vehicle operations. The characteristics to be determined are: a Torque ratio versus speed ratio and output speed b Input speed versus speed ratio and output speed c Efficiency versus speed ratio and output speed d Capacity factor versus speed ratio and output speed e Input torque versus input speed NOTE: For more information about these characteristics and the design of hydrodynamic drives, refer to “Design Practices: Passenger Car Automatic Transmissions,” SAE Advances in Engineering, AE-18 (Third Ed.) or AE-29 (Fourth Ed.).
The purpose of this SAE Recommended Practice is to establish guidelines for the automatic transmission and hydraulic systems engineer to design cast iron sealing rings and select acceptable width, thickness, coatings, and other accepted design details.
The purpose of this SAE Recommended Practice is to establish guidelines for the automatic transmission and hydraulic systems engineer to design cast iron sealing rings and select acceptable width, thickness, coatings, and other accepted design details.
The purpose of this SAE Recommended Practice is to establish specifications for use as a guide to the automatic transmission and hydraulic systems designer, helping him to select cast iron sealing ring width, thickness, coatings, and other accepted design details.
The purpose of this SAE Recommended Practice is to establish specifications for use as a guide to the automatic transmission and hydraulic systems designer, helping him to select cast iron sealing ring width, thickness, coatings, and other accepted design details.
This test procedure is intended to apply to hydraulic pump suction filters and strainers used in automotive automatic transmissions that include hydraulic power pumps. The various paragraphs of Section 5 include a variety of tests and alternative tests that are not applicable to all filters and applications, so the engineer must specify which tests are to be performed for a particular application. These test procedures are intended to evaluate filter functional performance characteristics only, durability is not evaluated under this standard. Filter design requirements must be specified by the engineer on the filter assembly drawing, an applicable engineering specification, or summarized on an application data sheet similar to that found in this recommended practice. See Figure 6. Pressure circuit filters, both barrier and system contamination control types, are not covered under this standard.
This test procedure is intended to apply to hydraulic pump suction filters and strainers used in automotive automatic transmissions that include hydraulic power pumps. The various paragraphs of Section 5, “Test Procedures,” include a variety of tests and alternative tests that are not applicable to all filters and applications, so the engineer must specify which tests are to be performed for a particular application. These test procedures are intended to evaluate filter functional performance characteristics only, durability is not evaluated under this standard. Filter design requirements must be specified by the engineer on the filter assembly drawing, an applicable engineering specification, or they may be summarized on an application data sheet similar to that found in this recommended practice. See Figure 6, “Filter Assembly Application and Data Sheet.” Pressure circuit filters, both barrier and system contamination control types, are not covered under this standard.
This test procedure is intended to apply to hydraulic pump suction filters and strainers used in automotive automatic transmissions that include hydraulic power pumps. The various paragraphs of Section 5, “Test Procedures,” include a variety of tests and alternative tests that are not applicable to all filters and applications, so the engineer must specify which tests are to be performed for a particular application. These test procedures are intended to evaluate filter functional performance characteristics only, durability is not evaluated under this standard. Filter design requirements must be specified by the engineer on the filter assembly drawing, an applicable engineering specification, or summarized on an application data sheet similar to that found in this recommended practice. See Figure 6, “Filter Assembly Application and Data Sheet.” Pressure circuit filters, both barrier and system contamination control types, are not covered under this standard.
This SAE Recommended Practice provides a method to determine the performance characteristics of the hydraulic oil pumps used in automatic transmissions and automatic transaxles. This document outlines the specific tests that describe the performance characteristics of these pumps over a range of operating conditions and the means to present the test data. This document is not intended to assess pump durability.
This SAE Recommended Practice provides a method to determine the performance characteristics of the hydraulic oil pumps used in automatic transmissions and automatic transaxles. This document outlines the specific tests that describe the performance characteristics of these pumps over a range of operating conditions and the means to present the test data. This document is not intended to assess pump durability.
This SAE Recommended Practice provides a method to determine the performance characteristics of the hydraulic oil pumps used in automatic transmissions and automatic transaxles. This document outlines the specific tests that describe the performance characteristics of these pumps over a range of operating conditions and the means to present the test data. This document is not intended to assess pump durability.