Refine Your Search

Topic

Search Results

Standard

Sound Power Level Measurements of Work Machines - Static and In-Place Dynamic Methods

2013-06-20
CURRENT
J1805_201306
This SAE Standard is used to determine the exterior A-weighted equivalent sound power level of static and in-place dynamic machines (dozer, loader, excavator, and backhoe) similar to the sound power obtained in ISO 6393 static and ISO 6395 dynamic sound power test procedures. Additional machine types, specifically sweepers and scrubbers, covered by SAE J2130 have been added, and other work machine types covered by SAE J1116 may be added with appropriate cycle descriptions and machine preparation. The recommended test procedures include conventional integrating sound pressure level methods or the sound intensity method using paired microphones. The sound intensity methodology provides a practical indoor alternative and permits measurement in the factory environment. The procedures in this document assume that the dominant sources are not highly sensitive to load (i.e., cooling fan, engine, track system).
Standard

Sound Measurement—Off-Road Self-Propelled Work Machines Operator-Work Cycle

2014-09-18
HISTORICAL
J1166_201409
This SAE Standard sets forth the procedures to be used in measuring sound levels and determining the time weighted sound level at the operator's station(s) of specified off-road self-propelled work machines. This document applies to the following work machines which have operator stations as specified in SAE J1116: • Crawler Loader • Grader • Log Skidder • Wheel Loader • Crawler Tractor with Dozer • Pipelayer • Dumper • Wheel Tractor with Dozer • Trencher • Tractor Scraper • Backhoe • Sweeper • Roller/Compactor • Hydraulic Excavator • Pad Foot Wheel Compactor with Dozer • Excavator and Wheel Feller-Buncher The instrumentation requirements and specific work cycles for these machines are described. The method used to calculate the time weighted average sound level at the operator station(s) is specified for Leq(5), or optional exchange rates, during continuous operation in a work cycle representing continuous medium to heavy work.
Standard

Sound Measurement—Construction Site

2007-11-09
HISTORICAL
J1075_200711
This SAE Standard sets forth measurement procedures and instrumentation to be used for determining a “representative” sound level during a representative time period at selected measurement locations on a construction site boundary. The document is not intended for use in determining occupational hearing damage risk. Determination of a representative time period is left to the judgment of the user.
Standard

Sound Measurement - Off-Road Work Machines - Operator - Singular Type

2013-07-24
CURRENT
J919_201307
This SAE Standard sets forth the instrumentation and procedure to be used in measuring sound pressure levels at the operator position for self-propelled off-road work machines as defined in SAE J1116. This document does not address the operation of safety devices such as backup alarms, horns, or accessories. This SAE document is applicable to machines that have operator stations where the operator can either stand or sit and will be either transported by, or walk with the machine during its operation. The sound levels obtained using this procedure are repeatable and representative of the higher range of sound levels generated by machines under actual field operating conditions. Due to variability of field operating conditions, this data is not intended to be used for operator noise exposure evaluations.
Standard

Sound Measurement - Off-Road Work Machines - Exterior

2013-06-20
CURRENT
J88_201306
This SAE Standard sets forth the instrumentation and procedure to be used in measuring the exterior sound pressure levels for self-propelled off-road work machines as defined in sections 1, 3, 5 and 6 of SAE J1116. This document does not address the operation of safety devices such as backup alarms, horns, or accessories. The sound levels obtained by using the test procedures set forth in this document are repeatable and are representative of the higher range of sound levels generated by machines under actual field operating conditions. Due to the variability of field operating conditions, this data is not intended to be used for construction site boundary noise evaluations.
Standard

Sound Measurement - Construction Site

2021-07-15
CURRENT
J1075_202107
This SAE Standard sets forth measurement procedures and instrumentation to be used for determining a “representative” sound level during a representative time period at selected measurement locations on a construction site boundary. The document is not intended for use in determining occupational hearing damage risk. Determination of a representative time period is left to the judgment of the user.
Standard

Sound Measurement - Construction Site

2013-03-19
HISTORICAL
J1075_201303
This SAE Standard sets forth measurement procedures and instrumentation to be used for determining a “representative” sound level during a representative time period at selected measurement locations on a construction site boundary. The document is not intended for use in determining occupational hearing damage risk. Determination of a representative time period is left to the judgment of the user.
Standard

SOUND POWER LEVEL MEASUREMENTS - EARTHMOVING MACHINERY (DOZER, LOADER, EXCAVATOR, AND BACKHOE) - IN PLACE DYNAMIC - SOUND PRESSURE LEVEL OR SOUND INTENSITY METHOD

1987-04-01
HISTORICAL
J1805_198704
The requirements for setting up and operating the machinery, the microphone array and hemispherical measurement surface are given in this document. This document shall be used in conjunction with manufacturer's recommendations pending finalization of ANSI documents on the subject of sound intensity procedures. The accompanying sound intensity procedure clarification is provided pending more widespread understanding of sound intensity.
Standard

SOUND MEASUREMENT—EARTHMOVING MACHINERY—EXTERIOR

1985-03-01
HISTORICAL
J88_198503
This SAE Standard is applicable to machinery of 15 kw (20 rated bhp) and over. It is not intended to cover operation of safety devices (such as backup alarms). The sound levels obtained by using the test procedures set forth in this SAE Standard are repeatable and are representative of the higher range of sound levels generated by the machinery under actual field operating conditions, but do not necessarily represent the average sound level over a field use cycle.
Standard

SOUND MEASUREMENT—CONSTRUCTION SITE

1985-04-01
HISTORICAL
J1075_198504
This SAE Recommended Practice sets forth measurement procedures and instrumentation to be used for determining a “representative” sound level during a representative time period at selected measurement locations on a construction site boundary. The practice is not intended for use in determining occupational hearing damage risk. Determination of a representative time period is left to the judgement of the user.
Standard

SOUND MEASUREMENT—CONSTRUCTION SITE

1985-08-01
HISTORICAL
J1075_198508
This SAE Recommended Practice sets forth measurement procedures and instrumentation to be used for determining a “representative” sound level during a representative time period at selected measurement locations on a construction site boundary. The practice is not intended for use in determining occupational hearing damage risk. Determination of a representative time period is left to the judgement of the user.
Standard

SOUND MEASUREMENT - CONSTRUCTION SITE

1987-03-01
HISTORICAL
J1075_198703
This SAE Standard sets forth measurement procedures and instrumentation to be used for determining a "representative" sound level during a representative time period at selected measurement locations on a construction site boundary. The standard is not intended for use in determining occupational hearing damage risk. Determination of a representative time period is left to the judgment of the user.
Standard

OPERATOR SOUND LEVEL MEASUREMENT PROCEDURE FOR EARTHMOVING MACHINERY—SINGULAR TYPE TEST

1979-04-01
HISTORICAL
J919C_197904
This SAE Standard is applicable to machinery of 15 kw (20 bhp) rated and over, that have operator stations where the operator can either stand or sit and will be transported by the machine during its operation. It is not intended for use with agricultural equipment. The sound levels obtained by using the test procedures set forth in this SAE Standard are in general repeatable, and are representative of the higher range of the sound levels generated by the machinery under field operating conditions, but do not necessarily represent the equivalent sound level over a field use cycle. For measurement and calculation of the operator’s sound exposure, use SAE Recommended Practice J1166a.
Standard

MEASUREMENT PROCEDURE FOR DETERMINING A REPRESENTATIVE SOUND LEVEL AT A CONSTRUCTION SITE BOUNDARY LOCATION

1978-04-01
HISTORICAL
J1075_197804
This SAE Recommended Practice sets forth procedures and instrumentation to be used for determining a representative sound level during a representative time period at selected measurement locations on a construction site boundary. It concerns the community adjacent to the construction site, and it is not intended for use in determining occupational hearing damage risk.
X