Standard

Windshield Defrosting Systems Test Procedure and Performance Requirements - Trucks, Buses, and Multipurpose Vehicles

2020-06-05
CURRENT
J381_202006
This SAE Recommended Practice establishes uniform test procedures and performance requirements for the defrosting system of enclosed cab trucks, buses, and multipurpose vehicles. It is limited to a test that can be conducted on uniform test equipment in commercially available laboratory facilities. For laboratory evaluation of defroster systems, current engineering practice prescribes that an ice coating of known thickness be applied to the windshield and left- and right-hand side windows to provide more uniform and repeatable test restults, even though—under actual conditions—such a coating would necessarily be scraped off before driving. The test condition, therefore, represents a more severe condition than the actual condition, where the defroster system must merely be capable of maintaining a cleared viewing area.
Standard

WINDSHIELD DEFROSTING SYSTEMS TEST PROCEDURE—TRUCKS, BUSES, AND MULTIPURPOSE VEHICLES

1974-05-01
HISTORICAL
J381_197405
This SAE Recommended Practice establishes uniform test procedures for the defrosting systems of enclosed cab trucks, buses, and multipurpose vehicles. It is limited to tests that can be conducted on uniform test equipment in commercially available laboratory facilities. Current engineering practice prescribes that for laboratory evaluation of defroster systems an ice coating of known thickness be applied to the windshield to provide more uniform and repeatable test results, even though under actual conditions such a coating would necessarily be scraped off before driving. The test condition, therefore, represents a more severe condition than the actual condition, where the defroster system must merely be capable of maintaining a cleared viewing area.
Standard

WINDSHIELD DEFROSTING SYSTEMS TEST PROCEDURE — TRUCKS, BUSES, AND MULTIPURPOSE VEHICLES

1968-02-01
HISTORICAL
J381_196802
This SAE Recommended Practice establishes uniform test procedures for the defrosting systems of enclosed cab trucks, buses, and multipurpose vehicles. It is limited to tests that can be conducted on uniform test equipment in commercially available laboratory facilities. Current engineering practice prescribes that for laboratory evaluation of defroster systems an ice coating of known thickness be applied to the windshield to provide more uniform and repeatable test results, even though under actual conditions such a coating would necessarily be scraped off before driving. The test condition, therefore, represents a more severe condition than the actual condition, where the defroster system must merely be capable of maintaining a cleared viewing area.
Standard

WINDSHIELD DEFROSTING SYSTEMS TEST PROCEDURE - TRUCKS, BUSES, AND MULTIPURPOSE VEHICLES

1984-06-01
HISTORICAL
J381_198406
This SAE Recommended Practice establishes uniform test procedures for the defrosting systems of enclosed cab trucks, buses, and multipurpose vehicles. It is limited to tests that can be conducted on uniform test equipment in commercially available laboratory facilities. Current engineering practice prescribes that for laboratory evaluation of defroster systems, an ice coating of known thickness be applied to the windshield to provide more uniform and repeatable test results, even though under actual conditions such a coating would necessarily be scraped off before driving. The test condition, therefore, represents a more severe condition than the actual condition, where the defroster system must merely be capable of maintaining a cleared viewing area.
Standard

Vehicle Testing Requirements for Replacement Refrigerants for CFC-12 (R-12) Mobile Air-Conditioning Systems

1999-02-01
HISTORICAL
J1659_199902
The purpose of this SAE Recommended Practice is to establish the specific criteria for the selection of a replacement refrigerant for mobile CFC-12 (R-12) air-conditioning (A/C) systems. This document provides guidelines for qualifying candidate refrigerant. The requirements include laboratory and field testing. The alternate refrigerant shall provide comparable system performance as CFC-12 (R-12) as defined herein. The vehicle testing shall be conducted on representative vehicle manufacturer's product line, in which the refrigerant is intended to be used, such as cycling clutch orifice tube, constant run orifice tube, cycling clutch expansion valve, or continuous run expansion valve refrigerant system. This document is complete only when combined with the requirements of SAE J1657.
Standard

Vehicle Idle Gear Rattle Evaluation Procedure

2017-09-19
CURRENT
J2555_201709
This SAE Standard describes a procedure to be used to evaluate a disturbance known as “idle gear rattle” which can exist in vehicles equipped with manual transmissions and clutches. Other types of noises associated with operation at idle are also briefly described.
Standard

Vehicle Idle Gear Rattle Evaluation Procedure

2000-11-01
HISTORICAL
J2555_200011
This SAE Standard describes a procedure to be used to evaluate a disturbance known as “idle gear rattle” which can exist in vehicles equipped with manual transmissions and clutches. Other types of noises associated with operation at idle are also briefly described.
Standard

Ultraviolet Leak Detection: Stability and Compatibility Criteria of Fluorescent Refrigerant Leak Detection Dyes for Mobile R-134a and R-1234yf (HFO-1234yf) Air-Conditioning Systems

2013-01-14
CURRENT
J2297_201301
This SAE Standard applies to dyes intended to be introduced into a mobile air-conditioning system refrigerant circuit for the purpose of allowing the application of ultraviolet leak detection. In order to label any product(s) they shall meet SAE J2297, and the certification process as described in SAE J2911 must be followed and the documentation described in the appendix shall be submitted to SAE.
Standard

Ultraviolet Leak Detection: Stability and Compatibility Criteria of Fluorescent Refrigerant Leak Detection Dyes for Mobile R-134a and R-1234yf (HFO-1234yf) Air-Conditioning Systems

2014-09-17
WIP
J2297
This SAE Standard applies to dyes intended to be introduced into a mobile air-conditioning system refrigerant circuit for the purpose of allowing the application of ultraviolet leak detection. In order to label any product(s) they shall meet SAE J2297, and the certification process as described in SAE J2911 must be followed and the documentation described in the appendix shall be submitted to SAE.
Standard

Thermal Flow Control Valve Nomenclature and Application

2023-05-15
WIP
J3142
The purpose of this SAE Information Report is to define common industry terminology and nomenclature relative to thermal flow control valves and to describe common thermal flow control valve applications in automotive, highway truck, mobile construction equipment, and industrial applications. This document is primarily directed at internal combustion engine or electric powered applications and the downstream systems to which power is provided, such as transmissions, hydraulics, air compression, etc. The information contained herein does not constitute an SAE Standard.
Standard

Thermal Containment Efficiency of Sleeve Materials

2008-09-04
HISTORICAL
J2495_200809
This SAE Standard measures the percent thermal efficiency of materials in sleeve form used to contain heat or insulate around a hot component. The percent thermal efficiency (%TE) is determined by measuring the power difference expended by the heat source (cartridge heater) with and without the test sleeve at the specified temperature. See SAE J2302 to measure radiant heat flow of sleeves.
Standard

Thermal Containment Efficiency of Sleeve Materials

1999-04-28
HISTORICAL
J2495_199904
This SAE Standard measures the percent thermal efficiency of materials in sleeve form used to contain heat or insulate around a hot component. The percent thermal efficiency (%TE) is determined by measuring the power difference expended by the heat source (cartridge heater) with and without the test sleeve at the specified temperature. See SAE J2302 to measure radiant heat flow of sleeves.
Standard

Test Procedure for Internal Heat Exchangers of Mobile Air-Conditioning Systems with R-134a or R-1234yf Refrigerant

2023-02-14
CURRENT
J3094_202302
The purpose of this SAE Standard is to define a common set of thermodynamic test conditions to evaluate internal heat exchangers for use with R-134a and R-1234yf refrigerants in mobile air-conditioning systems. This SAE Standard can be used to test actual vehicle IHX designs or standardized IHX samples, which can be used for comparison based on a common length and shape.
Standard

Test Procedure for Internal Heat Exchangers of Mobile Air-Conditioning Systems with R-134a or R-1234yf Refrigerant

2020-04-02
HISTORICAL
J3094_202004
The purpose of this SAE Standard is to define a common set of thermodynamic test conditions to evaluate internal heat exchangers for use with R-134a and R-1234yf refrigerants in mobile air-conditioning systems. This standard can be used to test actual vehicle IHX designs or standardized IHX samples, which can be used for comparison based on a common length and shape.