Standard

Secondary Filters for Fluid System Reliability

2004-12-01
HISTORICAL
AIR4057A
This SAE Aerospace Information Report (AIR) discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Secondary Filters for Fluid System Reliability

2012-09-24
CURRENT
AIR4057B
This SAE Aerospace Information Report (AIR) discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

SECONDARY FILTERS FOR FLUID SYSTEM RELIABILITY

1994-05-01
HISTORICAL
AIR4057
It discusses the design choices and engineering trade-offs available to the system designer in the efficient selection and application of Last-Chance filters in contrast to main or primary system filters.
Standard

Procedure for the Determination of Particulate Contamination of Air in Dust Controlled Spaces by the Manual Particle Count Method

2001-03-01
HISTORICAL
ARP743B
This SAE Aerospace Recommended Practice (ARP) describes two procedures for sampling particles in dust controlled spaces. One procedure covers airborne dust above 5 μm. The other (and newly added procedure) covers particles of 25 μm and larger that “fall out” of the environment onto surfaces. In each case the particles are sized in the longest dimension and counted. Airborne particles are reported as particles per cubic meter (cubic foot) whereas particles collected in fall out samples are reported as particles per 0.1 square meter (square foot). This document includes English units in parentheses as referenced information to the SI units where meaningful. These procedures may also be used for environmental analysis where the quality of the particles by visual or chemical analysis is intended.
Standard

Methods for Evaluating Cryogenic Filters

2002-03-23
HISTORICAL
ARP900A
The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 gpm (230 lpm) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system.
Standard

Methods for Evaluating Cryogenic Filters

2011-12-19
HISTORICAL
ARP900B
The purpose of this document is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters for particle sizes equal to or greater than 5.0 μm and flows up to and including 60 gpm (230 L/min) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system from those recommended in this document.
Standard

Methods for Evaluating Cryogenic Filters

2019-12-03
CURRENT
ARP900C
The purpose of this document is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures.
Standard

METHODS FOR EVALUATING CRYOGENIC FILTERS

1975-07-01
HISTORICAL
ARP900
The purpose of this test procedure is to present test methods that can be utilized to evaluate the filtration and operating characteristics of filters that will be utilized in a cryogenic system. The methods presented herein are intended to supplement standard filter testing specifications to allow evaluation of filter performance characteristics in areas that could be affected by extreme low temperatures. The test methods can be utilized to evaluate filters up to and including 60 GPM (330 liters per minute) capacity. If higher flow rate filters are to be evaluated in accordance with the test methods presented herein, it will be necessary to increase the system flow capacity and the size of effluent sampling system.
Standard

Importance of Physical and Chemical Properties of Aircraft Hydraulic Fluids

2011-02-08
HISTORICAL
AIR81C
This document discusses the relative merits of the physical and chemical properties of hydraulic fluids in relation to the aerospace hydraulic system design, and the related materials compatibility. The discussion in this report applies both to hydrocarbon and phosphate ester based aircraft hydraulic fluids. In some cases, numerical limits are suggested, but, in general, the significance and effect of a property is noted qualitatively.
Standard

Importance of Physical and Chemical Properties of Aircraft Hydraulic Fluids

2016-04-20
HISTORICAL
AIR81D
This document discusses the relative merits of the physical and chemical properties of hydraulic fluids in relation to the aerospace hydraulic system design, and the related materials compatibility. The discussion in this report applies both to hydrocarbon and phosphate ester based aircraft hydraulic fluids. In some cases, numerical limits are suggested, but, in general, the significance and effect of a property is noted qualitatively.
Standard

Importance of Physical and Chemical Properties of Aircraft Hydraulic Fluids

2019-10-02
CURRENT
AIR81E
This document discusses the relative merits of the physical and chemical properties of hydraulic fluids in relation to the aerospace hydraulic system design, and the related materials compatibility. The discussion in this report applies both to hydrocarbon and phosphate ester based aircraft hydraulic fluids. In some cases, numerical limits are suggested, but, in general, the significance and effect of a property is noted qualitatively.
Standard

HYDRAULIC FLUID CHARACTERISTICS

2011-08-10
HISTORICAL
AIR81
This report discusses the characteristics of hydraulic fluids and evaluates their importance, not only from the standpoint of fluid formulation, but also in their effect on aero-space hydraulic system design and the materials used in the components of the system. In some cases numerical parameter limits are suggested, but, in general, the effect of a parameter is the basic consideration. Not only must the characteristics of the fluid be considered in the design of a hydraulic system in which it is to be used, but also the characteristics of the system will affect the extent of the importance of the various characteristics of the fluid. In each individual system, as it employs a fluid, the characteristics of the fluid must be assessed with their immediate import and weighed in considering their effects on the system design requirements based upon the variables of system environment, function and basic design.
Standard

Fluid Properties

2007-11-29
HISTORICAL
AIR1116A
This report summarizes data relative to liquid fluids and their properties which are of interest to Aerospace Fluid Power technologists.