Refine Your Search

Topic

Search Results

Standard

Transparent Area Washing Systems for Aircraft

2006-03-27
HISTORICAL
AIR1102A
This information report presents data and recommendations pertaining to the design and development of transparent area washing systems for aircraft.
Standard

Thermophysical Characteristics of Working Fluids and Heat Transfer Fluids

2017-05-19
CURRENT
AIR1168/10A
This AIR is arranged in the following two sections: 2E - Thermodynamic Characteristics of Working Fluids, which contains thermodynamic diagrams for a number of working fluids currently in use and supplied by various industrial firms. 2F - Properties of Heat Transfer Fluids, which contains data, primarily in graphical form, on fluids that are frequently used in fluid heat transfer loops. Other properties of the environment, gases, liquids, and solids, can be found, as follows, in AIR1168/9: 2A-Properties of the Natural Environment 2B-Properties of Gases 2C-Properties of Liquids 2D-Properties of Solids
Standard

THERMOPHYSICAL CHARACTERISTICS OF WORKING FLUIDS AND HEAT TRANSFER FLUIDS

2011-06-21
HISTORICAL
AIR1168/10
This AIR is arranged in the following two sections: 2E - Thermodynamic Characteristics of Working Fluids, which contains thermodynamic diagrams for a number of working fluids currently in use and supplied by various industrial firms. 2F - Properties of Heat Transfer Fluids, which contains data, primarily in graphical form, on fluids that are frequently used in fluid heat transfer loops. Other properties of the environment, gases, liquids, and solids, can be found, as follows, in AIR1168/9: 2A-Properties of the Natural Environment 2B-Properties of Gases 2C-Properties of Liquids 2D-Properties of Solids
Standard

TESTING OF PROTOTYPE AIRPLANE AIR CONDITIONING SYSTEMS

1960-03-01
HISTORICAL
ARP217A
These recommendations are written to cover the testing of air conditioning equipment functioning as a complete and installed system in prototype civil aircraft for the purpose of: A Demonstrating the safety of the installation and equipment. B Demonstrating performance of the installation and equipment. a Source of heat b Source of fresh air and/or ventilation c The cooling system d Distribution system including ducting, joints, etc. e Water separator f Exhaust system g Temperature control system. h Cabin pressurisation system including flow and pressure controls. C Obtaining data for future design and to aid in the analysis of in-service performance of the systems and equipment.
Standard

TESTING OF PROTOTYPE AIRPLANE AIR CONDITIONING SYSTEMS

1951-03-15
HISTORICAL
ARP217
These recommendations are written to cover the testing of air conditioning equipment as installed in the prototype aircraft for the purpose of: A Demonstrating safety of the installation. B Demonstrating performance of the installation. a Aircraft ducting and distribution system. b Component parts (i.e., vendors equipment) C Obtaining data for future design.
Standard

Jet Blast Windshield Rain Removal Systems for Commercial Transport Aircraft

2008-11-06
HISTORICAL
AIR805B
The purpose of this information report is to present factors which affect the design and development of jet blast windshield rain removal systems for commercial transport aircraft. A satisfactory analytical approach to the design of these systems has not yet been developed. Although detailed performance data are available for some test configurations, rain removal systems will generally be unique to specific aircraft. This, then, requires a preliminary design for the system based on available empirical data to be followed with an extensive laboratory development program.
Standard

High Temperature Pneumatic Duct Systems for Aircraft

2022-03-21
WIP
ARP699F
This Recommended Practice is intended to outline the design, installation, testing, and field maintenance criteria for a high temperature metal pneumatic duct system, for use as a guide in the aircraft industry. These recommendations are to be considered as currently applicable and necessarily subject to revision from time to time, as a result of the rapid development of the industry.
Standard

High Temperature Pneumatic Duct Systems for Aircraft

2015-11-09
CURRENT
ARP699E
This Recommended Practice is intended to outline the design, installation, testing, and field maintenance criteria for a high temperature metal pneumatic duct system, for use as a guide in the aircraft industry. These recommendations are to be considered as currently applicable and necessarily subject to revision from time to time, as a result of the rapid development of the industry.
Standard

Guide for Qualification Testing of Aircraft Air Valves

2020-05-12
CURRENT
ARP986D
This SAE Aerospace Recommended Practice (ARP) defines recommended analysis and test procedures for qualification of pneumatically, electrically, manually, and hydraulically actuated air valves. They may be further defined as valves that function in response to externally applied forces or in response to variations in upstream and/or downstream duct air conditions in order to maintain a calibrated duct air condition (e.g., air flow, air pressure, air temperature, air pressure ratio, or air shutoff). Qualification testing performed on the airplane to verify compatibility of the valve function and stability as part of a complete system is outside the scope of this document. Refer to ARP1270 for design and certification requirements for cabin pressurization control system components. As this document is only a guide, it does not supersede or relieve any requirements contained in detailed Customer specifications.
Standard

Guide for Qualification Testing of Aircraft Air Valves

2008-11-06
HISTORICAL
ARP986C
This Aerospace Recommended Practice (ARP) defines tests to be performed on hydraulically, electrically, pneumatically, and mechanically actuated air valves. They may be further defined as those valves that function in response to externally applied forces or in response to variations in upstream and/or downstream duct air conditions in order to maintain a calibrated duct air condition (e.g., air flow, air pressure, air temperature, air pressure ratio, or air shutoff).
Standard

GUIDE FOR QUALIFICATION TESTING OF AIRCRAFT AIR VALVES

1990-02-28
HISTORICAL
ARP986B
This Aerospace Recommended Practice (ARP) defines tests to be performed on hydraulically, electrically, pneumatically, and mechanically actuated air valves. They may be further defined as those valves that function in response to externally applied forces or in response to variations in upstream and/or downstream duct air conditions in order to maintain a calibrated duct air condition (e.g., air flow, air pressure, air temperature, air pressure ratio, or air shutoff).
Standard

GUIDE FOR QUALIFICATION TESTING OF AIRCRAFT AIR VALVES

1968-11-01
HISTORICAL
ARP986
This document defines the tests to be performed on electrically, pneumatically, and mechanically actuated (regulating, modulating, and shutoff) air valves. The valves may be further defined as those which function in response to externally applied forces or in response to variations in upstream and/or downstream duct air conditions to maintain a calibrated duct air condition (i. e., air flow, air pressure, air temperature, air pressure ratio, etc. ). The requirements of this document should govern for all qualification tests unless different requirements are established by the detail specifications.
X