Refine Your Search

Topic

Search Results

Standard

Transfilling and Maintenance of Oxygen Cylinders

2008-11-17
HISTORICAL
AIR1059B
The purpose of this document is to list the best available information and guidelines for the qualification of personnel who are responsible for the filling of fixed or portable aircraft oxygen cylinders.
Standard

STANDARD FOR OXYGEN FLOW INDICATORS

1966-07-01
HISTORICAL
AS916
This standard is intended to establish general material and design requirements for oxygen flow indicating devices. Flow indicators considered are for diluter-demand and continuous flow systems.
Standard

Reducers, Oxygen Pressure

2023-01-26
CURRENT
AS17852A
This specification covers the requirements for two types of oxygen pressure reducers.
Standard

Reducers, Oxygen Pressure

2009-11-30
HISTORICAL
AS17852
This specification covers the requirements for two types of oxygen pressure reducers.
Standard

Passenger Oxygen Mask

2021-08-11
CURRENT
AS8025A
This standard covers oronasal type masks which use a continuous flow oxygen supply. Each such mask comprises a facepiece with valves as required, a mask suspension device, a reservoir, or rebreather bag (when used), a length of tubing for connection to the oxygen supply source, and a means for allowing the crew to determine if oxygen is being delivered to the mask. The assembly shall be capable of being stowed suitably to meet the requirements of its intended use.
Standard

PASSENGER OXYGEN MASK

1993-12-01
HISTORICAL
AS8025
This standard covers oronasal type masks which use a continuous flow oxygen supply. Each such mask comprises a facepiece with valves as required, a mask suspension device, a reservoir, or rebreather bag (when used), a length of tubing for connection to the oxygen supply source, and a means for allowing the crew to determine if oxygen is being delivered to the mask. The assembly shall be capable of being stowed suitably to meet the requirements of its intended use.
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

2014-10-16
CURRENT
AS452B
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

2003-10-15
HISTORICAL
AS452A
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
Standard

Oxygen Cylinder Quality, Serviceability, Maintenance Transfilling and Marking

2014-11-13
HISTORICAL
AIR1059D
This document provides guidance concerning the maintenance and serviceability of oxygen cylinders beginning with the quality of oxygen that is required, supplemental oxygen information, handling and cleaning procedures, transfilling and marking of serviced oxygen assemblies. This document attempts to outline in a logical sequence oxygen quality, serviceability and maintenance of oxygen cylinders.
Standard

Minimum Standards for Valve, High Pressure Oxygen, Line Shut Off, Manually Operated

2004-06-23
HISTORICAL
AS1214A
This standard covers all types of manually operated high pressure oxygen line shut off valves utilizing either metallic or nonmetallic valve seats for use in general and commercial type aircraft. It is intended that the line valve should be installed in a position accessible in flight, when the cylinder mounted oxygen valves are not. The line shutoff valve may also be used optionally in large systems as a maintenance aid where only a portion of the system need be opened up and purged after repair or replacement of one or more parts.
Standard

Minimum Standards for Valve, High Pressure Oxygen, Cylinder Shut Off, Manually Operated

2023-04-26
CURRENT
AS1066B
This standard covers all types of manually operated high pressure oxygen, cylinder shut off valves for use in commercial aircraft. It is intended that the valve shall be attached to a pressure cylinder storing oxygen under a nominal pressure of 12.76 MPa (1850 psig) at 21 °C (70 °F). Upon opening the valve, oxygen will be permitted to discharge from the storage cylinder to the valve outlet and to other downstream components of the oxygen system. It shall also be possible to recharge the cylinder through the valve.
Standard

Minimum Standard for Portable Gaseous, Oxygen Equipment

2000-03-01
HISTORICAL
AS1046B
This standard is intended to apply to that portable compressed gaseous oxygen equipment used for the administration of supplementary and/or first aid oxygen to one or more occupants of either private or commercial transport aircraft. This standard is applicable to the following types of portable oxygen equipment: a Continuous flow; b Demand flow; 1 Straight demand 2 Diluter demand 3 Pressure demand c Combination continuous flow and demand flow.
X