Thermal Vacuum Testing of the Capillary Pumped Loop Flight Experiment

1994-06-01
941599
The Capillary Pumped Loop Flight Experiment (CAPL) is a prototype of the Earth Observing System (EOS) instrument thermal control systems, which are based on two-phase heat transfer technology. The CAPL experiment has been functionally tested in a thermal vacuum chamber at NASA's Goddard Space Flight Center (GSFC). The tests performed included start-up tests, simulated EOS instrument power profiles, low and high power profiles, a variety of uneven coldplate heating tests, subcooling requirement tests, an induced deprime test, reprimes, saturation temperature changes, and a hybrid (mechanical pump-assist) test. There were a few unexpected evaporator deprimes, but overall the testing was successful. The results of all of the tests are discussed, with emphasis on the deprimes and suspected causes.
Technical Paper

Thermal Performance of Capillary Pumped Loops Onboard Terra Spacecraft

2004-07-19
2004-01-2504
The Terra spacecraft is the flagship of NASA’s Earth Science Enterprise. It provides global data on the atmosphere, land, and oceans, as well as their interactions with solar radiation and one another. Three Terra instruments utilize Capillary Pumped Heat Transport Systems (CPHTS) for temperature control. Each CPHTS, consisting of two capillary pumped loops (CPLs) and several heat pipes and electrical heaters, is designed for instrument heat loads ranging from 25W to 264W. The working fluid is ammonia. Since the launch of the Terra spacecraft in December 1999, each CPHTS has been providing a stable interface temperature specified by the instrument under all modes of spacecraft and instrument operations. The ability to change the CPHTS operating temperature upon demand while in service has also extended the useful life of one instrument. This paper describes the design and on-orbit performance of the CPHTS thermal systems.
Technical Paper

The Hybrid Capillary Pumped Loop

1988-07-01
881083
This paper describes the operational principles of a hybrid capillary pumped loop in general, and results on testing of a high power hybrid system in particular. A hybrid capillary pumped loop is a thermal control system which consists of a capillary pumped loop and a mechanical pump which is placed in series with the capillary evaporators in the liquid return line. The hybrid loop can be operated in either a passive capillary mode, or in a pump-assisted mode, whereby the mechanical pump augments the heat transport capability of the capillary evaporators. The high power hybrid system was built to demonstrate the feasibility of such a hybrid loop concept. Test results verified that a hybrid loop could be operated in either mode, and that transition between these two modes of operation required opening or closing a single valve on the liquid line.
Technical Paper

Testing of a Loop Heat Pipe with Two Evaporators and Two Condensers

2001-07-09
2001-01-2190
Most existing loop heat pipes (LHPs) consist of one single evaporator and one single condenser. LHPs with multiple evaporators are very desirable for cooling multiple heat sources or a heat source with large thermal footprints. Extending the current LHP technology to include multiple evaporators and multiple condensers faces some challenges, including operating temperature stability, adaptability of loop operation to rapid power and sink temperature transients, and sizing of the compensation chambers (CCs). This paper describes an overview of an extensive testing program for an LHP with two evaporators and two condensers. Tests performed include start-up, power cycle, sink temperature cycle, CC temperature cycle, and capillary limit. Test results showed that the loop could be started successfully in most cases, and the operating temperature was a function of the total heat load, heat load distribution between the two evaporators, condenser sink temperature and ambient temperature.
Technical Paper

Testing of a Capillary Pumped Loop with Multiple Parallel Starter Pumps

1997-07-01
972329
A capillary pumped loop (CPL) with a single starter pump in its evaporator section has been demonstrated to have very reliable start-ups and robust operation. In order to service payloads with large thermal footprints or to service multiple payloads, a CPL with multiple starter pumps seems a logical approach. However, questions were raised concerning its reliability for successful start-ups. In order to verify the feasibility of such a concept, a test program was conducted at NASA Goddard Space Flight Center, using four starter pumps plumbed in parallel. The main purpose of this experimental investigation was to verify the system's ability to provide a successful start-up and to retain performance characteristics demonstrated by a CPL with multiple evaporators of the traditional two-port pump design. Tests were conducted progressively by installing one, two and four pumps in the test loop.
Technical Paper

Testing of Flight Components for the Capillary Pumped Loop Flight Experiment

1993-07-01
932235
The Capillary Pumped Loop Flight Experiment (CAPL) is a prototype of the Earth Observing System (EOS) instrument thermal control systems. Four CAPL flight hardware components were tested in the Instrument Thermal Test Bed at NASA's Goddard Space Flight Center. The components tested were the capillary cold plates, capillary starter pump, heat pipe heat exchangers (HPHXs), and reservoir. The testing verified that all components meet or exceed their individual performance specifications. Consequently, the components have been integrated into the CAPL experiment which will be flown on the Space Shuttle in late 1993.
Technical Paper

Testing of A Loop Heat Pipe Subjected to Variable Accelerating Forces, Part 2: Temperature Stability

2000-07-10
2000-01-2489
Loop Heat Pipes (LHPs) are being considered for cooling of military combat vehicles and spinning spacecraft. In these applications, it is important to understand the effect of an accelerating force on the performance of LHPs. In order to investigate such an effect, a miniature LHP was installed on a spin table and subjected to variable accelerating forces by spinning the table at different angular speeds. Several patterns of accelerating forces were applied, i.e. continuous spin at different speeds and periodic spin at different speeds and frequencies. The resulting centrifugal accelerations ranged from 1.2 g's to 4.8 g's. This paper presents the second part of the experimental study, i.e. the effect of an accelerating force on the LHP operating temperature. It has been known that the LHP operating temperature under a stationary condition is a function of the evaporator power and the condenser sink temperature when the compensation temperature is not actively controlled.
Technical Paper

Start-Up Behaviors in the CAPL 2 Flight Experiment

1997-07-01
972328
The CAPL 2 Flight Experiment, flown on Space Shuttle STS-69 in 1995, was a flight demonstration of a full-scale prototype of a thermal control system planned for the Earth Observing System (EOS-AM) instruments Flight tests successfully demonstrated various CPL operations with simulated EOS-AM power profiles, including baseline and backup start-up procedures. In general, there were no significant differences in CPL performance between one-G and zero-G. However, some unusual behaviors were observed in several start-ups during the flight test. This paper describes CAPL 2 start-ups in detail, and offers explanations for the notably different zero-G behaviors.
Technical Paper

Performance of the CAPL 2 Flight Experiment

1996-07-01
961432
This paper describes flight test results of the CAPL 2 Flight Experiment, which is a full scale prototype of a capillary pumped loop (CPL) heat transport system to be used for thermal control of the Earth Observing System (EOS-AM) instruments. One unique feature of CAPL 2 is its capillary starter pump cold plate design, which consists of a single capillary starter pump and two heat pipes. The starter pump enhances start-up success due to its self-priming capability, and provides the necessary capillary pumping force for the entire loop. The heat pipes provide the required isothermalization of the cold plate. Flight tests included those pertinent to specific EOS applications and those intended for verifying generic CPL operating characteristics and performance limits. Experimental results confirmed that the starter pump was indeed self-priming and the loop could be successfully started every time.
Technical Paper

Operating Characteristics of Loop Heat Pipes

1999-07-12
1999-01-2007
The loop heat pipe (LHP) was invented in Russia in the early 1980’s. It is a two-phase heat transfer device that utilizes the evaporation and condensation of a working fluid to transfer heat, and the capillary forces developed in fine porous wicks to circulate the fluid. The LHP is known for its high pumping capability and robust operation because it uses fine-pored metal wicks and the integral evaporator/hydro-accumulator design. It has gained rapid acceptance in recent years as a thermal control device in space applications. This paper presents an overview of the LHP operation. The physical processes and the thermal-hydraulic behaviors of the LHP are first described. Operating characteristics as functions of various parameters including the heat load, sink temperature, ambient temperature, and elevation are presented. Peculiar behaviors in LHP operation such as temperature hysteresis and temperature overshoot during start-up are explained.
Technical Paper

Methods of Controlling the Loop Heat Pipe Operating Temperature

2008-06-29
2008-01-1998
The operating temperature of a loop heat pipe (LHP) is governed by the saturation temperature of its compensation chamber (CC); the latter is in turn determined by the balance among the heat leak from the evaporator to the CC, the amount of subcooling carried by the liquid returning to the CC, and the heat exchanged between the CC and ambient. Thus, the operating temperature of an LHP is a function of the evaporator heat input and the condenser sink temperature. The LHP operating temperature can be controlled at a desired set point by actively controlling the CC temperature. Several methods have been developed to control the CC temperature, including direct heating of the CC, coupling block, heat exchanger and separate subcooler, variable conductance heat pipe, vapor by-pass valve, secondary evaporator, and thermoelectric converter. The paper discusses the operating principles, advantages and disadvantages of each method.
Technical Paper

Mathematical Modeling of Multiple Evaporator / Multiple Condenser Loop Heat Pipes and Test Data Verification

2007-07-09
2007-01-3235
Loop Heat Pipes have proven as reliable heat transports for spacecraft thermal control systems. NASA Goddard Space Flight Center in collaboration with NASA Jet Propulsion Laboratory recently proposed a miniature dual pump/condenser LHP system for use in future Mars missions. Results of a ground test program indicated that the dual pump/condenser LHP performed very well, but in a complicated manner. No analytical model was available to facilitate the design/analysis of this emerging technology. A generalized LHP theory will be presented in this paper along with the derived governing equations and solution scheme. Model predictions were made and compared with test data for validation.
Technical Paper

Investigation of Low Power Operation in a Loop Heat Pipe

2001-07-09
2001-01-2192
This paper presents test results of an experimental study of low power operation in a loop heat pipe. The main objective was to demonstrate how changes in the vapor void fraction inside the evaporator core would affect the loop behavior. The fluid inventory and the relative tilt between the evaporator and the compensation chamber were varied so as to create different vapor void fractions in the evaporator core. The effect on the loop start-up, operating temperature, and capillary limit was investigated. Test results indicate that the vapor void fraction inside the evaporator core is the single most important factor in determining the loop operation at low powers.
Technical Paper

Hydrodynamic Aspects of Capillary Pumped Loops

1996-07-01
961435
The the past, the design of a Capillary Pumped Loop involved mainly on the thermodynamics and heat transfer aspects of the system. The fluid flow dynamics of the working fluid were deemed benign to the system performance. Recently theoretical and experimental studies have revealed several mechanisms that led to the deprime of the capillary pumps. These mechanisms were all related to the dynamics of the fluid movement inside the loop.
Technical Paper

Heat Load Sharing in a Capillary Pumped Loop With Multiple Evaporators and Multiple Condensers

2005-07-11
2005-01-2881
This paper describes the heat load sharing function among multiple parallel evaporators in a capillary pumped loop (CPL). In the normal mode of operation, the evaporators cool the instruments by absorbing the waste heat. When an instrument is turned off, the attached evaporator can keep it warm by receiving heat from other evaporators serving the operating instruments. This is referred to as heat load sharing. A theoretical basis of heat load sharing is given first. The fact that the wicks in the powered evaporators will develop capillary pressure to force the generated vapor to flow to cold locations where the pressure is lower leads to the conclusion that heat load sharing is an inherent function of a CPL with multiple evaporators. Heat load sharing has been verified with many CPLs in ground tests. Experimental results of the Capillary Pumped Loop 3 (CAPL 3) Flight Experiment are presented in this paper. Factors that affect the amount of heat being shared are discussed.
Technical Paper

Ground Tests of Capillary Pumped Loop (CAPL 3) Flight Experiment

1998-07-13
981812
The success of CAPL 2 flight experiment has stirred many interests in using capillary pumped loop (CPL) devices for spacecraft thermal control. With only one evaporator in the loop, CAPL 2 was considered a point design for the Earth Observing System (EOS-AM). To realize the full benefits of CPLs, a reliable system with multiple evaporators must be developed and successfully demonstrated in space. The Capillary Pumped Loop (CAPL 3) Flight Experiment was designed to flight demonstrate a multiple evaporator CPL in a space environment. New hardware and concepts were developed for CAPL 3 to enable reliable start-up, constant conductance operation, and heat load sharing. A rigorous ground test program was developed and extensive characterization tests were conducted. All performance requirements were met, and the loop demonstrated very reliable operation.
Technical Paper

Flight Testing of the Capillary Pumped Loop Flight Experiment

1995-07-01
951566
The Capillary Pumped Loop Flight Experiment (CAPL) employs a passive two-phase thermal control system that uses the latent heat of vaporization of ammonia to transfer heat over long distances. CAPL was designed as a prototype of the Earth Observing System (EOS) instrument thermal control systems. The purpose of the mission was to provide validation of the system performance in micro-gravity, prior to implementation on EOS. CAPL was flown on STS-60 in February, 1994, with some unexpected results related to gravitational effects on two-phase systems. Flight test results and post flight investigations will be addressed, along with a brief description of the experiment design.
Technical Paper

Flight Testing of a Cryogenic Capillary Pumped Loop

1999-08-02
1999-01-2627
This paper describes the flight test results of the fifth generation cryogenic capillary pumped loop (CCPL-5) which flew on the Space Shuttle STS-95 in October of 1998 as part of the CRYOTSU Flight Experiment. This flight was the first in-space demonstration of the CCPL, a lightweight heat transport and thermal switching device for future integrated cryogenic bus systems. The CCPL-5 utilized nitrogen as the working fluid and operated between 75K and 110K. Flight results indicated excellent performance of the CCPL-5 in a micro-gravity environment. The CCPL could start from a supercritical condition in all tests, and the reservoir set point temperature controlled the loop operating temperature regardless of changes in the heat load and/or the sink temperature. In addition, the loop demonstrated successful operation with heat loads ranging from 0.5W to 3W, as well as with parasitic heat loads alone.
Technical Paper

Effects of Gravity on Start-up and Heat Load Sharing of a Miniature Loop Heat Pipe

2007-07-09
2007-01-3234
This paper describes an experimental study on effects of gravity on the start-up and heat load sharing of a miniature loop heat pipe (MLHP) with two evaporators and two condensers. Each evaporator has an outer diameter of 9 mm and has its own integral compensation chamber (CC). For this experimental study, the MLHP was placed under five different configurations where the relative elevation and tilt among loop components were varied. The four well-known initial conditions between the evaporator and CC prior to the LHP start-up were created through combinations of: 1) the test configuration; 2) the method of pre-conditioning the loop prior to start-up, and 3) the heat load distribution between the evaporators. Effects of gravity on start-up transients and heat load sharing were clearly seen under otherwise the same heat load distribution and sink temperatures.
Technical Paper

Design Evolution of the Capillary Pumped Loop (CAPL 2) Flight Experiment

1996-07-01
961431
The Capillary Pumped Loop Flight Experiment (CAPL 2) employs a passive two-phase thermal control system that uses the latent heat of vaporization of ammonia to transfer heat over long distances. CAPL was designed as a prototype of the Earth Observing System (EOS) instrument thermal control systems. The purpose of the mission was to provide validation of the system performance in microgravity, prior to implementation on EOS. CAPL 1 was flown on STS-60 in February, 1994, with some unexpected results related to gravitational effects on two-phase systems. Start-up difficulties on CAPL 1 led to a redesign of the experiment (CAPL 2) and a reflight on STS-69 in September of 1995. The CAPL 2 flight was extremely successful and the new “starter pump” design is now baselined for the EOS application. This paper emphasizes the design history, the CAPL 2 design, and lessons learned from the CAPL program.