Technical Paper

Water Quality Program Elements for Space Station Freedom

1991-07-01
911400
Space Station Freedom (SSF) will be operational for up to 30 years with missions lasting up to 180 days. Because of the need for large amounts of potable and hygiene water for the crews, it will not be practical to supply water from the ground (as was done for Skylab) or to generate water from fuel cells (as is done for the Shuttle). Hence, waste and metabolic waters will be reclaimed and recycled in SSF. Because of the unique nature of the water sources and the closed loop recycling processes, providing safe water will be a challenging task. Developing a program for the verification of SSF water quality to ensure crew health is the responsibility of NASA's Medical Sciences Division at the Johnson Space Center (JSC). This program is being implemented through the Environmental Health System (EHS). This paper will describe the strategy for the development of water quality criteria and standards, and the associated monitoring requirements.
Technical Paper

Water Analysis Results from Phase II of the NASA Early Human Testing Initiative 30-Day Closed Chamber Test

1997-07-01
972555
An important milestone in the ongoing effort by NASA to develop and refine closed-loop water recycling systems for human space flight was reached during the summer of 1996 with the successful completion of Phase II of the Lunar Mars Life Support Testing Program at Johnson Space Center. Part of Phase II involved testing a water-recycling system in a closed test chamber continuously occupied by four human subjects for thirty days. The Phase II crew began the test with a supply of water that had been processed and certified for human use. As the test progressed, humidity condensate, urine, and wastewater from personal hygiene and housekeeping activities were reclaimed and reused several times. Samples were collected from various points in the reclamation process during the thirty day test. The data verified the water-processing hardware can reliably remove wastewater contaminants and produce reclaimed water that meets NASA standards for hygiene- and potable-quality water.
Technical Paper

Spacecraft Water System Disinfection Technology: Past, Present, and Future Needs

1987-07-01
871487
The lessons of past and present manned space programs are clear. Successful design and operation of a spacecraft water system is contingent upon consideration of traditional sanitary engineering principles in the context of unique mission requirements. However, the aerospace solution to the traditional terrestrial problem often requires an innovative design approach to succeed in the spacecraft environment. Future long duration space missions will require the same attention to basic principles, the same degree of innovation, and an extra measure of caution, because of the lack of terrestrial experience with direct human reuse of reclaimed water.
Technical Paper

Solid Phase Extraction of Polar Compounds in Water

1997-07-01
972465
The Water and Food Analytical Laboratory, at the Johnson Space Center is developing an alternative to EPA Method 625 for analyzing semivolatile organic compounds in water. The current EPA method uses liquid-liquid extraction. The alternative method being developed differs in the sample preparation phase by replacing gravity-dependent liquid-liquid extraction with solid phase extraction (SPE). The ultimate goal is to incorporate the optimum SPE conditions into an automated sample preparation process. The method shows promise with regard to anticipated polar compounds. Fourteen SPE resins and nine elution solvents were compared. For typical analytes encountered by our laboratory, a styrene-divinylbenzene SPE resin and an elution solvent mixture of methylene chloride and ethyl ether were found to give the highest extraction recoveries. A study is in progress to remove water from the extracts before GC/MS analysis.
Technical Paper

Single Phase Space Laundry Development

1993-07-01
932092
This paper describes a newly designed, 2.7 Kg (6 pound) capacity, laundry machine called the Single Phase Space Laundry (SPSL). The machine was designed to wash and dry crew clothing in a micro-gravity environment. A prototype unit was fabricated for NASA-JSC under a Small Business Innovative Research (SBIR) contract extending from September 1990 to January 1993. The unit employs liquid jet agitation, microwave vacuum drying, and air jet tumbling, which was perfected by KC-135 zero-g flight testing. Operation is completely automated except for loading and unloading clothes. The unit uses about 20 percent less power than a conventional household appliance.
Technical Paper

Shuttle Potable Water Quality from STS-26 to STS-114

2006-07-17
2006-01-2014
Potable water for the Shuttle orbiter is generated as a by-product of electricity production by the fuel cells. Water from the fuel cells flows through a Microbial Check Valve (MCV), which releases biocidal iodine into the water before it enters one of four storage tanks. Potable water is dispensed on-orbit at the rehydration unit of the galley. Due to crew health concerns, iodine removal hardware is installed in the chilled water inlet line to the galley to remove the iodine from the potable water before it is consumed by the crew. The Shuttle water system is sampled to ensure water quality is maintained during all operational phases from the disinfection of the ground servicing equipment through the completion of each mission. This paper describes and summarizes the Shuttle water quality requirements, the servicing of the Shuttle water system, the collection and analysis of Shuttle water samples, and the results of the analyses.
Technical Paper

Sampling and Chemical Analysis of Potable Water for ISS Expeditions 12 and 13

2007-07-09
2007-01-3214
The crews of Expeditions 12 and 13 aboard the International Space Station (ISS) continued to rely on potable water from two different sources, regenerated humidity condensate and Russian ground-supplied water. The Space Shuttle launched twice during the 12-months spanning both expeditions and docked with the ISS for delivery of hardware and supplies. However, no Shuttle potable water was transferred to the station during either of these missions. The chemical quality of the ISS onboard potable water supplies was verified by performing ground analyses of archival water samples at the Johnson Space Center (JSC) Water and Food Analytical Laboratory (WAFAL). Since no Shuttle flights launched during Expedition 12 and there was restricted return volume on the Russian Soyuz vehicle, only one chemical archive potable water sample was collected with U.S. hardware and returned during Expedition 12. This sample was collected in March 2006 and returned on Soyuz 11.
Technical Paper

Risk Mitigation Water Quality Monitor

1997-07-01
972463
On the International Space Station (ISS), atmospheric humidity condensate and other waste waters will be recycled and treated to produce potable water for use by the crews. Space station requirements include an on-orbit capability for real-time monitoring of key water quality parameters, such as total organic carbon, total inorganic carbon, total carbon, pH, and conductivity, to ensure that crew health is protected for consumption of reclaimed water. The Crew Health Care System for ISS includes a total organic carbon (TOC) analyzer that is currently being designed to meet this requirement. As part of the effort, a spacecraft TOC analyzer was developed to demonstrate the technology in microgravity and mitigate risks associated with its use on station. This analyzer was successfully tested on Shuttle during the STS-81 mission as a risk mitigation experiment. A total of six ground-prepared test samples and two Mir potable water samples were analyzed in flight during the 10-day mission.
Technical Paper

Regenerable Microbial Check Valve: Life Cycle Tests Results

1992-07-01
921316
The Microbial Check Valve (MCV) is a canister containing an iodinated ion exchange resin and is used on the Shuttle Orbiter to provide microbial control of potable water. The MCV provides a significant contact kill, and imparts a biocidal iodine residual to the water. The Orbiter MCV has a design life of 30 days. For longer duration applications, such as Space Station Freedom, an extended life is desirable to avoid resupply penalties. A method of in situ MCV regeneration with elemental iodine is being developed. During regeneration water en route to the MCV first passes through a crystalline iodine bed where a concentration between 200 - 300 mg/L I2 is attained. When introduced into the MCV, this high concentration causes an equilibrium shift towards iodine loading, effecting regeneration of the resin. After regeneration normal flow is re-established. Life cycle regeneration testing is currently in progress.
Technical Paper

Reduction in the Iodine Content of Shuttle Drinking Water: Lessons Learned

1999-07-12
1999-01-2117
Iodine is the disinfectant used in U.S. spacecraft potable water systems. Recent long-term testing on human subjects has raised concerns about excessive iodine consumption. Efforts to reduce iodine consumption by Shuttle crews were initiated on STS-87, using hardware originally designed to deiodinate Shuttle water prior to transfer to the Mir Space Station. This hardware has several negative aspects when used for Shuttle galley operations, and efforts to develop a practical alternative were initiated under a compressed development schedule. The alternative Low Iodine Residual System (LIRS) was flown as a Detailed Test Objective on STS-95. On-orbit, the LIRS imparted an adverse taste to the water due to the presence of trialkylamines that had not been detected during development and certification testing. A post-flight investigation revealed that the trialkylamines were released during gamma sterilization of the LIRS resin materials.
Technical Paper

Recent Experiences with Iodine Water Disinfection in Shuttle

1990-07-01
901356
Microbial proliferation in the STS potable water system is prevented by maintaining a 2-5 ppm iodine residual. The iodine is added to fuel cell water by an iodinated ion exchange resin in the Microbial Check Valve (MCV). Crew comments indicated excessive iodine in the potable water. To better define the problem, a method of in-flight iodine analysis was developed. Inflight analysis during STS-30 and STS-28 indicated iodine residuals were generally in the 9-13 ppm range. It was determined that the high iodine residual was caused by MCV influent temperatures in excess of 120 °F. This is well above the MCV operating range of 65-90 °F. The solution to this problem was to develop a resin suitable for the higher temperatures. Since 8 months were required to formulate a MCV resin suitable for the higher temperatures, a temporary solution was necessary. Two additional MCV's were installed on the chilled and ambient water lines leading into the galley to remove the excess iodine.
Technical Paper

Quality of Water Supplied by Shuttle to ISS

2002-07-15
2002-01-2532
The water supply for the International Space Station (ISS) consists partially of excess fuel-cell water that is treated on the Shuttle and stored on ISS in 44 L collapsible Contingency Water Containers (CWCs). Iodine is removed from the source water, and silver biocide and mineral concentrates are added by the crewmember while the CWCs are filled. Potable (mineralized) CWCs are earmarked for drinking and food hydration, and technical (non-mineralized) CWCs are reserved for waste system flushing and electrolytic oxygen generation. Representative samples are collected in Teflon® bags and returned to Earth for chemical analysis. The parameters typically measured include pH, conductivity, total organic carbon, iodine, silver, calcium, magnesium, fluoride, trace metals, formate and alcohols. The Nylon monomer caprolactam is also measured and tracked since it is known to leach slowly out of the plastic CWC bladder material.
Technical Paper

Potable Water Treatment and Transfer from Shuttle to Mir

1997-07-01
972461
To satisfy a requirement to supply water to Mir station, a process for treating iodinated water on the Shuttle was developed and implemented. The treatment system consists of packed columns for removing iodine and a syringe-based injection system for adding ionic silver, the biocide used in Mir water. Technical and potable grade water is produced and transferred in batches using collapsible 44-liter contingency water containers (CWCs). Silver is added to the water via injection of a solution from preloaded syringes. Minerals are also added to water destined for drinking. During the previous four Shuttle-Mir docking missions a total of 2781 liters (735 gallons) of water produced by the Shuttle fuel cells was processed using this method and transferred to Mir. To verify the quality of the processed water, samples were collected during flight and returned for chemical analysis.
Technical Paper

Microwave-Powered Thermal Regeneration of Sorbents for CO2, Water Vapor and Trace Organic Contaminants

1997-07-01
972430
Feasibility of the use of microwave heating to achieve fast and efficient thermal regeneration of sorbents for the removal of carbon dioxide, water vapor, and trace organics from contaminated air streams has been conclusively demonstrated. The use of microwave power offers several advantages, including: improved heat transfer, lower thermal losses, improved power utilization, and enhanced operational capabilities. During the initial research, the sorption and microwave-powered thermal desorption of acetone, trichloroethylene (TCE), carbon dioxide, and water vapor was studied at 2.45 GHz using a rectangular waveguide based test apparatus. Both activated carbon and Carbosieve S-III were identified as excellent microwave regenerable sorbents for use in the removal of airborne organics. Water loaded silica gel, Molecular Sieve 13X, and Molecular Sieve 5A were also effectively regenerated under microwave irradiation at this frequency.
Technical Paper

Microwave Powered Gravitationally Independent Medical Grade Water Generation

2007-07-09
2007-01-3176
The on-demand production of Medical Grade Water (MGW) is a critical biomedical requirement for future long-duration exploration missions. Potentially, large volumes of MGW may be needed to treat burn victims, with lesser amounts required to reconstitute pharmacological agents for medical preparations and biological experiments, and to formulate parenteral fluids during medical treatment. Storage of MGW is an untenable means to meet this requirement, as are nominal MGW production methods, which use a complex set of processes to remove chemical contaminants, inactivate all microorganisms, and eliminate endotoxins, a toxin originating from gram-negative bacteria cell walls. An innovative microgravity compatible alternative, using a microwave-based MGW generator, is described in this paper. The MGW generator efficiently couples microwaves to a single-phase flowing stream, resulting in super-autoclave temperatures.
Technical Paper

Microwave Enhanced Freeze Drying of Solid Waste

2007-07-09
2007-01-3266
A Microwave Enhanced Solid Waste Freeze Drying Prototype system has been developed for the treatment of solid waste materials generated during extended manned space missions. The system recovers water initially contained within wastes and stabilizes the residue with respect to microbial growth. Dry waste may then be safely stored or passed on to the next waste treatment process. Operating under vacuum, microwave power provides the energy necessary for sublimation of ice contained within the waste. This water vapor is subsequently collected as relatively pure ice on a Peltier thermoelectric condenser as it travels en route to the vacuum pump. In addition to stabilization via dehydration, microwave enhanced Freeze Drying reduces the microbial population (∼90%) in the waste.
Journal Article

Microgravity Evaluation of Colorimetric-Solid Phase Extraction for the Measurement of Total I (Iodine, Iodide, and Triiodide) in Spacecraft Drinking Water

2008-06-29
2008-01-2199
We are developing a drinking water test kit based on colorimetric-solid phase extraction (C-SPE) for use onboard the International Space Station (ISS) and on future Lunar and/or Mars missions. C-SPE involves measuring the change in diffuse reflectance of indicator disks following their exposure to a water sample. We previously demonstrated the effectiveness of C-SPE in measuring iodine in microgravity. This analytical method has now been extended to encompass the measurement of total I (i.e., iodine, iodide, and triiodide). This objective was accomplished by introducing an oxidizing agent to convert iodide and triiodide to iodine, which is then measured using the indicator disks previously developed for iodine. We report here the results of a recent series of C-9 microgravity tests of this method. The results demonstrate that C-SPE technology is poised to meet the total I monitoring requirements of the international space program.
Technical Paper

Magnetically Assisted Gasification of Solid Wastes: Comparison of Reaction Strategies

2005-07-11
2005-01-3081
Gradient magnetically assisted fluidized bed (G-MAFB) methods are under development for the decomposition of solid waste materials in microgravity and hypogravity environments. The G-MAFB has been demonstrated in both laboratory and microgravity flight experiments. In this paper we summarize the results of gasification reactions conducted under a variety of conditions, including: combustion, pyrolysis (thermal decomposition), and steam reforming with and without oxygen addition. Wheat straw, representing a typical inedible plant biomass fraction, was chosen for this study because it is significantly more difficult to gasify than many other typical forms of solid waste such as food scraps, feces, and paper. In these experiments, major gasification products were quantified, including: ash, char, tar, carbon monoxide, carbon dioxide, methane, oxygen, and hydrogen.
Technical Paper

Magnetically Assisted Filtration of Solid Wastes: Laboratory and Flight Experiments

2005-07-11
2005-01-3082
Solid wastes can be separated from aqueous streams and concentrated by filtration in a magnetically assisted fluidized bed. In this work the filtration of solid waste materials using filter beds consisting of granular ferromagnetic media is demonstrated. The degree of bed consolidation (or conversely fluidization) is controlled by the application of magnetic forces. In the Magnetically Assisted Gasification (MAG) process, solids are first entrapped by filtration, and then fluidized and transferred to a high temperature reactor where they are thermally decomposed. The maximum particle loading for the filter bed is determined by the intergranular void space. Using magnetic methods, it is possible to manipulate the degree of compaction as the filtration progresses to increase the void space and thereby maximize the loading capacity and efficiency of the filter. This process is completely compatible with operation in microgravity and hypogravity.
Technical Paper

Liquid Metering Centrifuge Sticks (LMCS): A Centrifugal Approach to Metering Known Sample Volumes for Colorimetric Solid Phase Extraction (C-SPE)

2007-07-09
2007-01-3216
Phase separation is one of the most significant obstacles encountered during the development of analytical methods for water quality monitoring in spacecraft environments. Removing air bubbles from water samples prior to analysis is a routine task on earth; however, in the absence of gravity, this routine task becomes extremely difficult. This paper details the development and initial ground testing of liquid metering centrifuge sticks (LMCS), devices designed to collect and meter a known volume of bubble-free water in microgravity. The LMCS uses centrifugal force to eliminate entrapped air and reproducibly meter liquid sample volumes for analysis with Colorimetric Solid Phase Extraction (C-SPE). Previous flight experiments conducted in microgravity conditions aboard the NASA KC-135 aircraft demonstrated that the inability to collect and meter a known volume of water using a syringe was a limiting factor in the accuracy of C-SPE measurements.