Refine Your Search

Topic

Search Results

Standard

Temperature Instruments (Reciprocating Engine Powered Aircraft)

2008-02-16
CURRENT
AS413B
This Aerospace Standard covers two basic types of temperature instruments as follows: TYPE I: Ratiometer type, actuated by changes in electrical resistance of a temperature sensing electrical resistance element; the resistance changes being obtained by temperature changes of the temperature sensing resistance element. TYPE II: Millivoltmeter type, operated and actuated by varying E.M.F. output of a thermocouple; the varying E.M.F. input to the instrument being obtained by temperature changes of the temperature sensing thermocouple.
Standard

TURN AND BANK INDICATOR

1947-07-01
CURRENT
AS395
This specification covers three basic types of instruments as follows: TYPE I - Air Driven TYPE II - D-C Operated TYPE III - A-C Operated
Standard

TEMPERATURE INSTRUMENTS (TURBINE POWERED SUBSONIC AIRCRAFT)

2008-02-16
CURRENT
AS414B
This SAE Aerospace Standard (AS) covers two basic types of temperature instruments as follows: Type I: Ratiometer type, actuated by changes in electrical resistance of a temperature sensing electrical resistance element; the resistance changes being obtained by temperature changes of the temperature sensing resistance element. Type II: Millivoltmeter type, operated and actuated by varying EMF output of a thermocouple; the varying EMF input to the instrument being obtained by temperature changes of the temperature sensing thermocouple.
Standard

TEMPERATURE INDICATOR

1954-12-01
HISTORICAL
AS413A
This Aeronautical Standard covers two basic types of temperature indicators as follows: TYPE I - Ratiometer type actuated by changes of electrical resistance of a temperature sensing electrical resistance element; the resistance changes being obtained by temperature changes of the temperature sensing resistance element. TYPE II - Millivoltmeter type, operated and actuated by varying e.m.f. output of a thermocouple, the varying e.m.f. input to the instrument being obtained by temperature changes of the temperature sensing thermocouple.
Standard

TEMPERATURE INDICATOR

1948-11-01
HISTORICAL
AS413
This specification covers two types of instruments. These instruments are for the purpose of measuring temperature, such as those of oil coolant, carburetor air, free air and cylinder head.
Standard

Synchros

1955-07-01
HISTORICAL
ARP461
This document is limited to units meeting the definitions of para. 1.3 and covers the following general class of synchros: 26 volt, 400 cycle synchros 115 volt, 400 cycle synchros 115 volt, 60 cycle synchros
Standard

Single-Degree-of-Freedom Spring-Restrained Rate Gyros

2008-02-16
CURRENT
AS1104
This specification covers that gyroscopic instrument normally defined as a "subminiature rate gyro." The rate gyro, when subjected to an angular rate about its input axis, provides an AC output voltage proportional to the angular rate. The subminiature size category generally includes gyro instruments of one (1) inch diameter or less and three and one-half (3 1/2) inches length or less. This specification defines the requirements for a subminiature spring-restrained, single-degree-of-freedom rate gyro for aircraft, missile, and spacecraft applications.
Standard

SYNCHROS

2008-02-16
CURRENT
ARP461B
This document is limited to units meeting the definitions of para. 1.3 and covers the following general class of synchros:
Standard

SYNCHROS

1959-11-15
HISTORICAL
ARP461A
This document is limited to units meeting the definitions of para. 1.3 and covers the following general class of synchros:
Standard

Remote Servoed Air Data Instruments for Subsonic Aircraft

2008-02-16
CURRENT
AS791
This standard provides minimum performance criteria for air data instruments intended to provide cockpit indication of: a Indicated airspeed (Vi) b Computer airspeed (Vc) c True airspeed (Vt) d Equivalent airspeed (Ve) e Mach number (M) f Altitude (H) g Vertical speed (Hpr) h Maximum operating limit speed (Vmo) i True angle of attack (αt) j Free air temperature (Tfat) k Total temperature (Tt) These functions shall be derived from a central air data computer (AS 417) and through system wiring applied to the respective indicator.
Standard

Rate of Climb (Vertical Speed) Indicator, Pressure Actuated (Turbine Powered Subsonic Aircraft)

2008-02-16
CURRENT
AS429
This Aerospace Standard covers four basic types of direct reading pressure actuated rate of climb (vertical speed) indicators as follows: Type I - Range 0-2000 feet per minute climb and descent Type II - Range 0-3000 feet per minute climb and descent Type III - Range 0-4000 feet per minute climb and descent Type IV - Range 0-6000 feet per minute climb and descent
Standard

PRESSURE INSTRUMENTS - FUEL, OIL, AND HYDRAULIC

1954-12-15
HISTORICAL
AS408A
This aeronautical standard covers two basic types of pressure instruments. These are intended for use in measuring fuel, oil or hydraulic pressures as follows: This aeronautical standard does not apply to engine mounted torque meter systems.
Standard

PRECISION MOTOR TACHOMETER GENERATOR

2008-02-16
CURRENT
ARP667
This recommended practice establishes objectives for high performance control motor tachometer generators to be used with aeronautical and associated equipment in protective enclosures or completely within the shell of the aircraft so that they are subjected only to the internal climatic conditions of heat, cold, shock, vibration, and humidity. Control motor tachometer generators larger than size 23 are not covered in this document.