This SAE Aerospace Recommended Practice (ARP) defines the nomenclature of temperature measuring devices. General temperature measurement related terms are defined first, followed by nomenclature specific to temperature measuring devices, particularly thermocouples.
The thermocouple design recommended herein is presented as one for which the correction to the observed emf, because of thermal conduction along the stem and wires, is within the limits presented in the accompanying figure. On referring to the figure, it is seen that no restriction is placed upon the diameter of the thermocouple or stem, and the longitudinal dimensions are expressed in terms of wire and stem diameters. The type of stem, such as packed ceramic stock, refractory insulating tubing, etc., also is left open to choice. Thus the sizes of wires and supporting stems may be varied over wide ranges to match particular requirements where conduction errors are to be limited or controlled.
The ice bath recommended herein is similar to that described in SAE AIR 46.* Some material not presented in AIR 46, including preferred dimensions, has been added.
The purpose of this SAE Aerospace Information Report (AIR) is to provide information and guidance for the selection and use of lubrication system monitoring methods. This AIR is intended to be used as a technical guide. It is not intended to be used as a legal document or standard. The scope of this document is limited to those inspection and analysis methods and devices that can be considered appropriate for routine maintenance.
The purpose of this Aerospace Information Report (AIR) is to provide information and guidance for the selection and use of oil system monitoring devices and methods. This AIR is intended to be used as a technical guide. It is not intended to be used as a legal document or standard. The scope of this document is limited to those inspection and analysis methods and devices which can be considered appropriate for routine maintenance. In agreement with industry usage, wear particle size ranges are given in μm (1 μm = 10-3 millimeter = 10-6 meter). Other dimensions are given in millimeters, with inches in parenthesis.
The purpose of this SAE Aerospace Information Report (AIR) is to provide information and guidance for the selection and use of oil system monitoring devices and methods. This AIR is intended to be used as a technical guide. It is not intended to be used as a legal document or standard. The scope of this document is limited to those inspection and analysis methods and devices that can be considered appropriate for routine maintenance. In agreement with industry usage, wear particle size ranges are given in micrometers (1 μm = 10-3 mm = 10-6 m).