Refine Your Search

Topic

Search Results

Standard

Thread Sealants

2021-01-27
CURRENT
J1615_202101
Male pipe threads, including male dryseal pipe threads, when made into assemblies or installed into ports, will generally leak if not covered with a sealant. This SAE Recommended Practice is intended as a guide to assist designers and/or users in the selection and application of various types of thread sealants. The designers and users must make a systematic review of each type and application and then select the sealant to fulfill the requirements of the application. The following are general guidelines and are not necessarily a complete list.
Standard

Spherical and Flanged Sleeve (Compression) Tube Fittings

2000-02-22
HISTORICAL
J246_200002
This SAE Standard covers complete general and dimensional specifications for tube fittings of the spherical and flanged sleeve compression types for use in the piping of air brake systems on automotive vehicles. The spherical sleeve compression type Figures 1A to 5 and Tables 1 to 3 is intended for use with annealed copper alloy tubing per SAE J1149, Type 1. The flanged sleeve compression type Figures 6A to 11 and Tables 4 to 6 is intended for use with nylon tubing per SAE J844. It is not intended to restrict or preclude other designs of a tube fitting for use with SAE J844, air brake tubing. Performance requirements for SAE J844 are covered in SAE J1131. See SAE J1131 for the Performance Requirements of Reusable (Push to Connect) Fittings Intended for Use in Automotive Air Brake Systems.
Standard

SPHERICAL AND FLANGED SLEEVE (COMPRESSION) TUBE FITTINGS

1996-01-01
HISTORICAL
J246_199601
This SAE Standard covers complete general and dimensional specifications for tube fittings of the spherical and flanged sleeve compression types for use in the piping of air brake systems on automotive vehicles. The spherical sleeve compression type Figures 1A to 5 and Tables 1 to 3 is intended for use with annealed copper alloy tubing per SAE J1149, Type 1. The flanged sleeve compression type Figures 6A to 11 and Tables 4 to 6 is intended for use with nylon tubing per SAE J844. It is not intended to restrict or preclude other designs of a tube fitting for use with SAE J844, air brake tubing. Performance requirements for SAE J844 are covered in SAE J1131. See SAE J1131 for the Performance Requirements of Reusable (Push to Connect) Fittings Intended for Use in Automotive Air Brake Systems.
Standard

REFRIGERATION TUBE FITTINGS—GENERAL SPECIFICATIONS

1994-05-01
HISTORICAL
J513_199405
This SAE Standard covers complete general and dimensional specifications for refrigeration tube fittings of the flare type specified in Figures 1 to 42 and Tables 1 to 16. These fittings are intended for general use with flared annealed copper tubing in refrigeration applications. Dimensions of single and double 45 degree flares on tubing to be used in conjunction with these fittings are given in Figure 2 and Table 1 of SAE J533. The following general specifications supplement the dimensional data contained in Tables 1 to 16 with respect to all unspecified details.
Standard

REFRIGERATION TUBE FITTINGS—GENERAL SPECIFICATIONS

1996-06-01
HISTORICAL
J513_199606
This SAE Standard covers complete general and dimensional specifications for refrigeration tube fittings of the flare type specified in Figures 1 to 42 and Tables 1 to 15. These fittings are intended for general use with flared annealed copper tubing in refrigeration applications. Dimensions of single and double 45 degree flares on tubing to be used in conjunction with these fittings are given in Figure 2 and Table 1 of SAE J533. The following general specifications supplement the dimensional data contained in Tables 1 to 15 with respect to all unspecified details.
Standard

REFRIGERATION TUBE FITTINGS—GENERAL SPECIFICATIONS

1993-06-01
HISTORICAL
J513_199306
This SAE Standard covers complete general and dimensional specifications for refrigeration tube fittings of the flare type specified in Figures 1 to 42 and Tables 1 to 16. These fittings are intended for general use with flared annealed copper tubing in refrigeration applications. Dimensions of single and double 45 degree flares on tubing to be used in conjunction with these fittings are given in Figure 2 and Table 1 of SAE J533. The following general specifications supplement the dimensional data contained in Tables 1 to 16 with respect to all unspecified details.
Standard

REFRIGERATION TUBE FITTINGS

1968-05-01
HISTORICAL
J513C_196805
This standard covers complete general and dimensional specifications for refrigeration flare type tube fittings intended for general use with flared annealed copper tubing in refrigeration applications. Also included is an appendix covering the coding system for identification of fittings. The inclusion of dimensional data in this standard is not intended to imply that all of the fittings described are stock production items. Consumers are requested to consult with manufacturers concerning availability.
Standard

REFRIGERATION TUBE FITTINGS

1977-10-01
HISTORICAL
J513F_197710
This standard covers complete general and dimensional specifications for refrigeration tube fittings of the flare type specified in Figs. 1-42 and Tables 1-16. These fittings are intended for general use with flared annealed copper tubing in refrigeration applications. Dimensions of single and double 45 deg flares on tubing to be used in conjunction with these fittings are given in Fig. 2 and Table 1 of SAE J533. The following general specifications supplement the dimensional data contained in Tables 1-16 with respect to all unspecified detail.
Standard

REFRIGERATION TUBE FITTINGS

1977-10-01
HISTORICAL
J513_197710
This standard covers complete general and dimensional specifications for refrigeration tube fittings of the flare type specified in Figs. 1-42 and Tables 1-16. These fittings are intended for general use with flared annealed copper tubing in refrigeration applications. Dimensions of single and double 45 deg flares on tubing to be used in conjunction with these fittings are given in Fig. 2 and Table 1 of SAE J533. The following general specifications supplement the dimensional data contained in Tables 1-16 with respect to all unspecified details.
Standard

REFRIGERATION TUBE FITTINGS

1990-06-01
HISTORICAL
J513_199006
This SAE Standard covers complete general and dimensional specifications for refrigeration tube fittings of the flare type specified in Figures 1 to 42 and Tables 3 to 18. These fittings are intended for general use with flared annealed copper tubing in refrigeration applications. Dimensions of single and double 45 degree flares on tubing to be used in conjunction with these fittings are given in Figure 2 and Table 1 of SAE J533. The following general specifications supplement the dimensional data contained in Tables 3 to 18 with respect to all unspecified details.
Standard

Performance Requirements for SAE J844 Nonmetallic Air Brake Tubing and SAE J246 Compression Fitting Assemblies Used in Vehicular Air Brake Systems

2021-05-06
CURRENT
J1131_202105
This SAE Standard is intended to establish uniform performance criteria and methods of testing compression tube fittings with SAE J844 air brake tubing as used in vehicular air brake systems. This document also establishes minimum qualifications for tensile and pressure capabilities, vibration durability under cyclic temperatures, serviceability, and fitting compatibility requirements. The specific tests and performance criteria applicable to the tubing are set forth in SAE J844. NOTE: The test values contained in this performance standard are for test purposes only. For environmental and usage limitations, refer to SAE J844. For fittings, a type of fitting for use with SAE J844 nonmetallic tubing is included in SAE J246; however, it is not intended to restrict or preclude the use of other designs of fittings that comply with this document.
Standard

PERFORMANCE REQUIREMENTS FOR SAE J844d NONMETALLIC TUBING AND FITTING ASSEMBLIES USED IN AUTOMOTIVE AIR BRAKE SYSTEMS

1976-01-01
HISTORICAL
J1131_197601
This standard is intended to establish uniform methods of testing SAE J844d tubing and fitting assemblies as used in automotive air brake systems. This standard also establishes minimum qualifications for tensile and pressure capabilities, vibrational durability under cyclic temperatures, serviceability, and fitting compatibility requirements. The specific tests and performance criteria applicable to the tubing are set forth in SAE J844d. Note: The test values contained in this performance standard are for test purposes only. For environmental and usage limitations see SAE J844d. Fittings – A type of fitting for use with SAE J844d nonmetallic tubing is included in SAE J246b, however, it is not intended to restrict or preclude the use of other designs of fittings that comply with this standard.
Standard

PERFORMANCE REQUIREMENTS FOR SAE J844 NONMETALLIC TUBING AND FITTING ASSEMBLIES USED IN AUTOMOTIVE AIR BRAKE SYSTEMS

1987-12-01
HISTORICAL
J1131_198712
This standard is intended to establish uniform methods of testing SAE J844 tubing and fitting assemblies as used in automotive air brake systems. This standard also establishes minimum qualifications for tensile and pressure capabilities, vibrational durability under cyclic temperatures, serviceability, and fitting compatibility requirements. The specific tests and performance criteria applicable to the tubing are set forth in SAE J844. Note—The test values contained in this performance standard are for test purposes only. For environmental and usage limitations see SAE J844. Fittings—A type of fitting for use with SAE J844 nonmetallic tubing is included in SAE J246b; however, it is not intended to restrict or preclude the use of other designs of fittings that comply with this standard.
Standard

PERFORMANCE REQUIREMENTS FOR SAE J844 NONMETALLIC TUBING AND FITTING ASSEMBLIES USED IN AUTOMOTIVE AIR BRAKE SYSTEMS

1997-03-01
HISTORICAL
J1131_199703
This SAE Standard is intended to establish uniform methods of testing SAE J844 tubing and fitting assemblies as used in automotive air brake systems. This document also establishes minimum qualifications for tensile and pressure capabilities, vibrational durability under cyclic temperatures, serviceability, and fitting compatibility requirements. The specific tests and performance criteria applicable to the tubing are set forth in SAE J844.
Standard

Nonmetallic Air Brake System Tubing

1998-06-01
HISTORICAL
J844_199806
This SAE Standard covers the minimum requirements for nonmetallic tubing as manufactured for use in air brake systems. Nonreinforced products are designated type A and reinforced products type B. It is not intended to cover tubing for any portion of the system which operates below −40 °C (–40 °F), above +93°C (+200 °F), above a maximum working gage pressure of 1030 kPa (150 psi), or in an area subject to attack by battery acid. This tubing is intended for use in the brake system for connections which maintain a basically fixed relationship between components during vehicle operation. Coiled tube assemblies required for those installations where flexing occurs are covered by this document and SAE J1131 to the extent of setting minimum requirements on the essentially straight tube and tube fitting connections which are used in the construction of such assemblies2.
Standard

Metric Nonmetallic Air Brake System Tubing1

2000-04-01
HISTORICAL
J1394_200004
This SAE Standard covers the minimum requirements for metric sizes of nonmetallic tubing as manufactured for use in air brake systems. Nonreinforced products are designated type A and reinforced products type B. It is not intended to cover tubing for any portion of the system that operates below −40 °C (−40 °F), above +93 °C (+200 °F), above a maximum working gage pressure of 1.0 MPa (150 psi), or in an area subject to attack by battery acid. This tubing is intended for use in the brake system for connections that maintain a basically fixed relationship between components during vehicle operation. Coiled tube assemblies required for those installations where flexing occurs are covered by this standard and SAE J1131 to the extent of setting minimum requirements on the essentially straight tube and tube fitting connections, which are used in the construction of such assemblies.2
Standard

METRIC NONMETALLIC AIR BRAKE SYSTEM TUBING

1991-04-01
HISTORICAL
J1394_199104
This SAE Standard covers the minimum requirements for metric sizes of nonmetallic tubing as manufactured for use in air brake systems. Nonreinforced products are designated type A and reinforced products type B. It is not intended to cover tubing for any portion of the system that operates below −40 °C (−40 °F), above +93 °C (+200 °F), above a maximum working gage pressure of 1.0 MPa (150 psi), or in an area subject to attack by battery acid. This tubing is intended for use in the brake system for connections that maintain a basically fixed relationship between components during vehicle operation. Coiled tube assemblies required for those installations where flexing occurs are covered by this standard and SAE J1131 to the extent of setting minimum requirements on the essentially straight tube and tube fitting connections, which are used in the construction of such assemblies.2
Standard

METALLIC AIR BRAKE SYSTEM TUBING AND PIPE

1991-06-01
HISTORICAL
J1149_199106
This SAE Standard covers minimum requirements for two types of metallic tubing and pipe as used in automotive air brake systems. It includes material and performance specifications, corrosion precautions, and installation recommendations. Copper tubing is designated Type 1, and galvanized steel pipe Type 2.
Standard

Automotive Tube Fittings

2022-03-31
CURRENT
J512_202203
This SAE Standard covers complete general and dimensional specifications for the various types of tube fittings intended for general application in the automotive, appliance, and allied fields. See SAE J1131 for the performance requirements of reusable (push to connect) fittings intended for use in automotive air brake systems. Flare type fittings shall be as specified in Figures 1 to 4 and Tables 3 to 5. NOTE—For sizes 3/16 to 3/8 and 1/2 to 3/4 the flare type fittings depicted in Figures 1A to 3C are identical with the corresponding refrigeration tube fittings specified in SAE J513. Special size combination fittings 3/16 to 3/8 and 1/2 to 3/4 shall be as specified in SAE J513. Inverted flared type fittings shall be as specified in Figures 5 to 11 and Tables 3, 6, 7, 8, and 9. Gages and gaging procedures pertaining to inverted flared tube fittings are given in Appendix A.
Standard

Automotive Pipe, Filler, and Drain Plugs

2020-02-03
CURRENT
J531_202002
This SAE Standard includes complete general and dimensional specifications for those types of pipe, filler, and drain plugs (shown in Figures 1 to 6 and Tables 1 to 4) commonly used in automotive and related industrial applications.