RECOMMENDED STANDARD FOR AEROSPACE FILTER ELEMENT FINE WIRE MESH

2011-02-11
HISTORICAL
AIR888
This AIR discusses the nature, method of manufacture and chemistry of fine wire meshes of the type used for filtration and similar applications, and how this information may be utilized in setting up a quality control program to insure reliability of meshes used for such applications.
Standard

Procedure for the Determination of Particulate Contamination of Air in Dust Controlled Spaces by the Manual Particle Count Method

2001-03-01
HISTORICAL
ARP743B
This SAE Aerospace Recommended Practice (ARP) describes two procedures for sampling particles in dust controlled spaces. One procedure covers airborne dust above 5 μm. The other (and newly added procedure) covers particles of 25 μm and larger that “fall out” of the environment onto surfaces. In each case the particles are sized in the longest dimension and counted. Airborne particles are reported as particles per cubic meter (cubic foot) whereas particles collected in fall out samples are reported as particles per 0.1 square meter (square foot). This document includes English units in parentheses as referenced information to the SI units where meaningful. These procedures may also be used for environmental analysis where the quality of the particles by visual or chemical analysis is intended.
Standard

PROCEDURE FOR THE DETERMINATION OF PARTICULATE CONTAMINATION OF HYDRAULIC FLUIDS BY THE PARTICLE COUNT METHOD

1991-11-01
HISTORICAL
ARP598
This test describes a self-checking procedure for the determination of particulate contaminant five microns or greater in size in hydraulic fluids by the particle count method. A maximum variation of two to one (±33% of the average of two runs) in results should be expected for replicate counts on the same sample, providing that the procedure is followed closely and the precautions presented on pages 10 and 11 of the procedure, regarding manipulation, check samples and self-checking aspects, are observed.
Standard

PHYSICAL PROPERTIES OF HYDRAULIC FLUIDS

1991-11-01
HISTORICAL
AIR1362
This report presents data on hydraulic fluids which are of interest to detail designers of hydraulic systems and components for military flight vehicles. The data pertain to fluids conforming to specifications MIL-H-5606, MIL-H-8446, MIL-H-27601, and MIL-H-83282.
Standard

Methods, Locations and Criteria for System Sampling and Measuring the Solid Particle Contamination of Hydraulic Fluids

2021-05-06
CURRENT
ARP5376C
This Aerospace Recommended Practice (ARP) provides: Recommended methods for cleaning sample bottles, when used, and the solvents to be applied and how these solvents should be prepared. Recommendations for three measuring methods for determining the level of solid particle contamination of hydraulic fluids used in aerospace hydraulics. Recommendations for the selection of the sampling point, sampling method, and the sampling frequency.
Standard

Methods, Locations And Criteria For System Sampling And Measuring The Solid Particle Contamination Of Hydraulic Fluids

2010-03-08
HISTORICAL
ARP5376B
This SAE Aerospace Recommended Practice (ARP) provides procedures for assuring cleanliness of sampling equipment, for performing the sampling process, and for measuring and reporting the sample particle count. The ARP gives procedures for cleaning sample bottles, when used, and recommends the solvents to be applied and how these solvents should be prepared. Requirements for the selection of the sampling point, sampling method, and sampling frequency are also specified. This ARP also recommends three measuring methods for determining the level of solid particle contamination of hydraulic fluids used in aerospace hydraulics. These are: a on-line automatic particle counting; b automatic particle counting method using bottle samples; c microscopic particle count method using bottle samples.
Standard

Liquid Filter Ratings, Parameters and Tests

2021-04-29
CURRENT
AIR887C
This SAE Aerospace Information Report (AIR) identifies and explains the meaning of various ratings and terms used to describe the physical characteristics of liquid filter elements. The significance of various filter parameters is discussed. In addition, a number of filter test methods are briefly described. This AIR and the data presented are only applicable where the system liquid wets the filter elements.
Standard

LIQUID FILTER RATINGS, PARAMETERS AND TESTS

1993-02-03
HISTORICAL
AIR887B
This SAE Aerospace Information Report (AIR) identifies and explains the meaning of various ratings and terms used to describe the physical characteristics of liquid filter elements. The significance of various filter parameters is discussed. In addition, a number of filter test methods is briefly described. This AIR and the data presented are only applicable to filters in which the system liquid wets the filter elements. This document includes equivalent metric units (in parentheses) as referenced information.
Standard

LIQUID FILTER RATINGS, PARAMETERS AND TESTS

2011-08-10
HISTORICAL
AIR887A
This AIR identifies and explains the meaning of various ratings and terms used to describe the physical characteristics of liquid filter elements. The significance of various filter parameters are discussed. In addition, a number of filter test methods are briefly described. This AIR and the data presented are only applicable to filters in which the system liquid wets the filter elements.
Standard

LIQUID FILTER RATINGS

1968-05-31
HISTORICAL
AIR887
This AIR explains the meaning of "ABSOLUTE" and "NOMINAL" ratings which are used to describe liquid filter element physical characteristics. A set of standard filter ratings and methods of determination to further describe an element performance are also included. These data are only applicable to a system in which the system liquid wets the filter element.