Refine Your Search

Topic

Author

Search Results

Technical Paper

Water Quality Program Elements for Space Station Freedom

1991-07-01
911400
Space Station Freedom (SSF) will be operational for up to 30 years with missions lasting up to 180 days. Because of the need for large amounts of potable and hygiene water for the crews, it will not be practical to supply water from the ground (as was done for Skylab) or to generate water from fuel cells (as is done for the Shuttle). Hence, waste and metabolic waters will be reclaimed and recycled in SSF. Because of the unique nature of the water sources and the closed loop recycling processes, providing safe water will be a challenging task. Developing a program for the verification of SSF water quality to ensure crew health is the responsibility of NASA's Medical Sciences Division at the Johnson Space Center (JSC). This program is being implemented through the Environmental Health System (EHS). This paper will describe the strategy for the development of water quality criteria and standards, and the associated monitoring requirements.
Technical Paper

Water Analysis Results from Phase II of the NASA Early Human Testing Initiative 30-Day Closed Chamber Test

1997-07-01
972555
An important milestone in the ongoing effort by NASA to develop and refine closed-loop water recycling systems for human space flight was reached during the summer of 1996 with the successful completion of Phase II of the Lunar Mars Life Support Testing Program at Johnson Space Center. Part of Phase II involved testing a water-recycling system in a closed test chamber continuously occupied by four human subjects for thirty days. The Phase II crew began the test with a supply of water that had been processed and certified for human use. As the test progressed, humidity condensate, urine, and wastewater from personal hygiene and housekeeping activities were reclaimed and reused several times. Samples were collected from various points in the reclamation process during the thirty day test. The data verified the water-processing hardware can reliably remove wastewater contaminants and produce reclaimed water that meets NASA standards for hygiene- and potable-quality water.
Technical Paper

Utilization of the Space Station Detergent IGEPON by a Candidate Organism for Use in a Space Biological Waste Reactor

1998-07-13
981608
The microgravity environment of space introduces a major new variable for consideration that will affect the design and operation of bioreactors. Adequate aeration for aerobic bioreactors will be a challenge as will gas/liquid separation, removal of carbon dioxide and other bacterial metabolic waste products, control algorithms, and overall performance assessment. These challenges must be addressed in order to fully assess the efficacy of biological approaches to the recovery of potable water from wastewater in microgravity. The first step in this process is to define the fermentation parameters of the organism or consortia that will be used in these space bioreactors. This study was designed to investigate the ability of bacteria to degrade the space station detergent IGEPON.
Technical Paper

Treatment Bed Microbiological Control

1987-07-01
871492
The effects of microbial fouling on treatment bed (TB) performance are being studied. Fouling of activated carbon (AC) and ion exchange resins (IEX) by live and devitalized bacteria can cause decreased capacity for selected sorbates with AC and IEX TB. More data are needed on organic species removal in the trace region of solute sorption isotherms. TB colonization was prevented by nonclassical chemical disinfectant compositions (quaternary ammonium resins) applied in suitable configurations. Recently, the protection of carbon beds via direct disinfectant impregnation has shown promise. Effects (of impregnation) upon bed sorption/removal characteristics are to be studied with representative contaminants. The potential need to remove solutes added or produced during water disinfection and/or TB microbiological control must be investigated.
Technical Paper

Total Organic Carbon Analyzer For ISS

1998-07-13
981765
On the International Space Station (ISS), atmospheric humidity condensate and other waste waters will be recycled and treated to produce potable water for use by the crews. Space Station requirements include an on-orbit capability for real-time monitoring of key water quality parameters, such as total organic carbon (TOC), total inorganic carbon (TIC), total carbon (TC), pH, and conductivity, to ensure that crew health is protected during consumption of reclaimed water. The Crew Health Care System (CHeCS) for ISS includes an analyzer that has been designed to meet this requirement. The analyzer is adapted from commercially successful technology, and it measures TOC and TIC throughout the range from 1 to 50,000 μg/L, and TC from 1 to 100,000 μg/L. It measures pH between 2.0 and 12.0 pH units, and conductivity from 0.1 to 300 μmho/cm. The analyzer is scheduled for launch to ISS on mission 2A.1.
Technical Paper

The Development of a Volatile Organics Concentrator for Use in Monitoring Space Station Water Quality

1991-07-01
911435
An approach to the isolation and concentration of volatile organic compounds from a water sample prior to chemical analysis in a microgravity environment has been previously described (Reference 1). The Volatile Organics Concentrator (VOC) system was designed for attachment to a gas chromatograph/mass spectrometer (GC/MS) for analysis of the volatile organics in water on Space Station Freedom. The VOC concept utilizes a primary solid sorbent for collection and concentration of the the organics from water, with subsequent transfer using nitrogen gas through a permeation dryer tube to a secondary solid sorbent tube. The secondary solid sorbent is thermally desorbed to a gas chromatograph for separation of the volatiles which are detected using a mass spectrometer.
Technical Paper

The Development and Testing of a Volatile Organics Concentrator for Use in Monitoring Space Station Water Quality

1992-07-01
921266
An approach to the isolation and concentration of volatile organic compounds from a water sample prior to chemical analysis in a microgravity environment has been previously described (Reference 1). The Volatile Organics Concentrator (VOC) system was designed to attach to a gas chromatograph/mass spectrometer (GC/MS) for analysis of volatile organic compounds in water on Space Station Freedom. The VOC utilizes a primary solid sorbent for collection and concentration of the volatile compounds, transfer of the volatiles through a permeation dryer to a secondary solid sorbent, followed by thermal desorption of volatiles from the secondary sorbent onto a GC/MS system. Fabrications and preliminary testing of the VOC breadboard using a gas chromatography equipped with flame ionization detector has been previously described (Reference 2). These results have indicated that the VOC will meet or exceed the goals set for the program.
Technical Paper

Test Results of a Shower Water Recovery System

1987-07-01
871512
A shower test was conducted recently at NASA-JSC in which waste water was reclaimed and reused. Test subjects showered in a prototype whole body shower following a protocol similar to that anticipated for Space Station. The waste water was purified using reverse osmosis followed by filtration through activated carbon and ion exchange resin beds. The reclaimed waste water was maintained free of microorganisms by using both heat and iodine. This paper discusses the test results, including the limited effectiveness of using iodine as a disinfectant and the evaluation of a Space Station candidate soap for showering. In addition, results are presented on chemical and microbial impurity content of water samples obtained from various locations in the water recovery process.
Technical Paper

Space Station Microscopy: Beyond the Box

1993-07-01
932143
Microscopy aboard Space Station Freedom poses many unique challenges for in-flight investigations. Disciplines such as materials processing, plant and animal research, human research, environmental monitoring, health care, and biological processing have diverse microscope requirements. The typical microscope not only does not meet the comprehensive needs of these varied users, but also tends to require excessive crew time. To assess user requirements, a comprehensive survey was conducted among investigators with experiments requiring microscopy. The survey examined requirements such as light sources, objectives, stages, focusing systems, eye pieces, video accessories, etc. The results of this survey and the application of an Intelligent Microscope Imaging System (IMIS) may address these demands for efficient microscopy service in space.
Technical Paper

Space Station Freedom Viewed as a “Tight Building”

1990-07-01
901382
The Space Station Freedom (SSF), with a 30-year projected lifetime and a completely closed-loop Environmental Control and Life Support System (ECLSS), is perhaps the ultimate “Tight Building.” Recognizing the potential for the development of “Tight Building Syndrome” (TBS), and initiating actions to minimize possible TBS occurrences on SSF, requires a multidisciplinary approach that begins with appropriate design concerns and ends with detection and control measures on board SSF. This paper will present a brief summary of current experience with TBS on Earth. While many of the circumstances and methodologies garnered from investigating tight buildings on Earth are similar to those that might be encountered aboard SSF, the Station also presents a unique environment and a special set of constraints which will require an adaptation of previous protocols. Air contamination, including volatile organic compounds and microorganisms, will be the focus of the discussion.
Technical Paper

Space Station Environmental Health System Water Quality Monitoring

1990-07-01
901351
One of the unique aspects of the Space Station is that it will be a totally encapsulated environment and the air and water supplies will be reclaimed for reuse. The Environmental Health System, a subsystem of CHeCS (Crew Health Care System), must monitor the air and water on board the Space Station Freedom to verify that the quality is adequate for crew safety. Specifically, the Water Quality Subsystem will analyze the potable and hygiene water supplies regularly for organic, inorganic, particulate, and microbial contamination. The equipment selected to perform these analyses will be commercially available instruments which will be converted for use on board the Space Station Freedom. Therefore, the commercial hardware will be analyzed to identify the gravity dependent functions and modified to eliminate them.
Technical Paper

Solid Phase Extraction of Polar Compounds in Water

1997-07-01
972465
The Water and Food Analytical Laboratory, at the Johnson Space Center is developing an alternative to EPA Method 625 for analyzing semivolatile organic compounds in water. The current EPA method uses liquid-liquid extraction. The alternative method being developed differs in the sample preparation phase by replacing gravity-dependent liquid-liquid extraction with solid phase extraction (SPE). The ultimate goal is to incorporate the optimum SPE conditions into an automated sample preparation process. The method shows promise with regard to anticipated polar compounds. Fourteen SPE resins and nine elution solvents were compared. For typical analytes encountered by our laboratory, a styrene-divinylbenzene SPE resin and an elution solvent mixture of methylene chloride and ethyl ether were found to give the highest extraction recoveries. A study is in progress to remove water from the extracts before GC/MS analysis.
Technical Paper

Role of Environmental Factors in Immunity and Infectious Disease Risk

2005-07-11
2005-01-2763
Environmental monitoring of microbial contaminants is important for crew health and assessing functionality of engineering systems. Routine monitoring of air and surfaces on the International Space Station found Staphylococcus spp. to be the most common bacterial species whereas Aspergillus spp. were the most common fungi. The levels of microbial contaminants in the air and surfaces were typically low and within the acceptability limits. Bacterial levels in the potable water from the hot water port were uniformly low. Levels in water from the warm port and the SVO-ZV water distribution system exceeded acceptability limits on occasion. Methylobacterium spp. And Ralstonia spp. were the bacteria most commonly isolated from the potable water systems. The space environment, stress, and other factors may also diminish the host immune system. The status of antimicrobial functions of neutrophils and monocytes was determined by flow cytometry.
Technical Paper

Risk Mitigation Water Quality Monitor

1997-07-01
972463
On the International Space Station (ISS), atmospheric humidity condensate and other waste waters will be recycled and treated to produce potable water for use by the crews. Space station requirements include an on-orbit capability for real-time monitoring of key water quality parameters, such as total organic carbon, total inorganic carbon, total carbon, pH, and conductivity, to ensure that crew health is protected for consumption of reclaimed water. The Crew Health Care System for ISS includes a total organic carbon (TOC) analyzer that is currently being designed to meet this requirement. As part of the effort, a spacecraft TOC analyzer was developed to demonstrate the technology in microgravity and mitigate risks associated with its use on station. This analyzer was successfully tested on Shuttle during the STS-81 mission as a risk mitigation experiment. A total of six ground-prepared test samples and two Mir potable water samples were analyzed in flight during the 10-day mission.
Technical Paper

Review of Water Disinfection Techniques

1987-07-01
871488
Throughout the history of manned space flight the supply of potable water to the astronauts has presented unique problems. Of particular concern has been the microbiological quality of the potable water. This has required the development of both preflight water system servicing procedures to disinfect the systems and inflight disinfectant addition and monitoring devices to ensure continuing microbiological control. The disinfectants successfully used to date have been aqueous chlorine or iodine. Because of special system limitations the use of iodine has been the most successful for inflight use and promises to be the agent most likely to be used in the future. Future spacecraft potable, hygiene, and experiment water systems will utilize recycled water. This will present special problems for water quality control. NASA is currently conducting research and development to solve these problems.
Technical Paper

Results on Reuse of Reclaimed Shower Water

1986-07-14
860983
A microgravity whole body shower (WBS) and a waste water recovery system (WWRS) were used in a closed loop test at the Johnson Space Center. The WWRS process involved chemical pretreatment, phase change distillation and post-treatment. A preprototype Thermoelectric Integrated Hollow Fiber Membrane Evaporation Subsystem (TIMES) was used for distillation after pretreatment and the post-treatment was accomplished with activated carbon, mixed ion exchange resin beds and microbial check valve (MCV) iodine bactericide dispensing units. The purposes of this test were to evaluate a NASA approved Shuttle soap for whole body showering comfort; evaluate the effects of the shower water on the WBS and the TIMES; and evaluate purification qualities of the recovered water in a closed loop operation.
Technical Paper

Regenerable Microbial Check Valve: Life Cycle Tests Results

1992-07-01
921316
The Microbial Check Valve (MCV) is a canister containing an iodinated ion exchange resin and is used on the Shuttle Orbiter to provide microbial control of potable water. The MCV provides a significant contact kill, and imparts a biocidal iodine residual to the water. The Orbiter MCV has a design life of 30 days. For longer duration applications, such as Space Station Freedom, an extended life is desirable to avoid resupply penalties. A method of in situ MCV regeneration with elemental iodine is being developed. During regeneration water en route to the MCV first passes through a crystalline iodine bed where a concentration between 200 - 300 mg/L I2 is attained. When introduced into the MCV, this high concentration causes an equilibrium shift towards iodine loading, effecting regeneration of the resin. After regeneration normal flow is re-established. Life cycle regeneration testing is currently in progress.
Technical Paper

Regenerable Biocide Delivery Unit

1991-07-01
911406
The Microbial Check Valve (MCV) is used on the Space Shuttle to impart an iodine residual to the drinking water to maintain microbial control. Approximately twenty MCV locations have been identified in the Space Station Freedom design, each with a 90 day life. This translates to 2400 replacement units in 30 years of operation. An in situ regeneration concept has been demonstrated that will reduce this replacement requirement to less than 300 units based on data to date and potentially fewer as further regenerations are accomplished. A totally automated system will result in significant savings in crew time, resupply requirements and replacement costs. An additional feature of the device is the ability to provide a concentrated biocide source (200 mg/liter of I2) that can be used to superiodinate systems routinely or after a microbial upset. This program was accomplished under NASA Contract Number NAS9-18113.
Technical Paper

Reduction in the Iodine Content of Shuttle Drinking Water: Lessons Learned

1999-07-12
1999-01-2117
Iodine is the disinfectant used in U.S. spacecraft potable water systems. Recent long-term testing on human subjects has raised concerns about excessive iodine consumption. Efforts to reduce iodine consumption by Shuttle crews were initiated on STS-87, using hardware originally designed to deiodinate Shuttle water prior to transfer to the Mir Space Station. This hardware has several negative aspects when used for Shuttle galley operations, and efforts to develop a practical alternative were initiated under a compressed development schedule. The alternative Low Iodine Residual System (LIRS) was flown as a Detailed Test Objective on STS-95. On-orbit, the LIRS imparted an adverse taste to the water due to the presence of trialkylamines that had not been detected during development and certification testing. A post-flight investigation revealed that the trialkylamines were released during gamma sterilization of the LIRS resin materials.
Technical Paper

Recent Experiences with Iodine Water Disinfection in Shuttle

1990-07-01
901356
Microbial proliferation in the STS potable water system is prevented by maintaining a 2-5 ppm iodine residual. The iodine is added to fuel cell water by an iodinated ion exchange resin in the Microbial Check Valve (MCV). Crew comments indicated excessive iodine in the potable water. To better define the problem, a method of in-flight iodine analysis was developed. Inflight analysis during STS-30 and STS-28 indicated iodine residuals were generally in the 9-13 ppm range. It was determined that the high iodine residual was caused by MCV influent temperatures in excess of 120 °F. This is well above the MCV operating range of 65-90 °F. The solution to this problem was to develop a resin suitable for the higher temperatures. Since 8 months were required to formulate a MCV resin suitable for the higher temperatures, a temporary solution was necessary. Two additional MCV's were installed on the chilled and ambient water lines leading into the galley to remove the excess iodine.
X