Refine Your Search

Topic

Search Results

Standard

Testing of Oxygen Equipment

2021-08-11
CURRENT
ARP1398A
This ARP delineates requirements for system cleanliness, test gas supply system, test stand design, environmental chamber definition, instrumentation, dynamic test equipment and testing procedures.
Standard

Reducers, Oxygen Pressure

2009-11-30
HISTORICAL
AS17852
This specification covers the requirements for two types of oxygen pressure reducers.
Standard

Passenger Oxygen Mask

2021-08-11
CURRENT
AS8025A
This standard covers oronasal type masks which use a continuous flow oxygen supply. Each such mask comprises a facepiece with valves as required, a mask suspension device, a reservoir, or rebreather bag (when used), a length of tubing for connection to the oxygen supply source, and a means for allowing the crew to determine if oxygen is being delivered to the mask. The assembly shall be capable of being stowed suitably to meet the requirements of its intended use.
Standard

PASSENGER OXYGEN MASK

1993-12-01
HISTORICAL
AS8025
This standard covers oronasal type masks which use a continuous flow oxygen supply. Each such mask comprises a facepiece with valves as required, a mask suspension device, a reservoir, or rebreather bag (when used), a length of tubing for connection to the oxygen supply source, and a means for allowing the crew to determine if oxygen is being delivered to the mask. The assembly shall be capable of being stowed suitably to meet the requirements of its intended use.
Standard

Oxygen Systems for General Aviation

2001-10-01
HISTORICAL
AIR822A
This SAE Aerospace Information Report (AIR) provides a general overview of oxygen systems for general aviation use. Included are a brief review of the factors and effects of hypoxia, system descriptions, and mission explanations for system or component selection, and techniques for safe handling of oxygen distribution systems.
Standard

Oxygen Systems for General Aviation

2006-06-05
HISTORICAL
AIR822B
This SAE Aerospace Information Report (AIR) provides a general overview of oxygen systems for general aviation use. Included are a brief review of the factors and effects of hypoxia, system descriptions, and mission explanations for system or component selection, and techniques for safe handling of oxygen distribution systems.
Standard

Oxygen Systems for General Aviation

2014-07-11
CURRENT
AIR822C
This SAE Aerospace Information Report (AIR) provides a general overview of oxygen systems for general aviation use. Included are a brief review of the factors and effects of hypoxia, system descriptions, and mission explanations for system or component selection, and techniques for safe handling of oxygen distribution systems.
Standard

Oxygen System Integration and Performance Precautions

2002-04-01
HISTORICAL
AIR825/12
Oxygen system integration and performance precautions are in particularly dependent on applicable sections of airworthiness requirements per FAR/JAR 25. In this document information will be provided on common principles and good practices regarding design criteria, installation, manufacturing, safety aspects and system handling during maintenance and inspection.
Standard

Oxygen System Integration and Performance Precautions

2018-10-18
CURRENT
AIR825/12A
Oxygen system integration and performance precautions are in particularly dependent on applicable sections of airworthiness requirements per FAR/JAR 25. In this document information will be provided on common principles and good practices regarding design criteria, installation, manufacturing, safety aspects and system handling during maintenance and inspection.
Standard

Oxygen Sensor Technologies

2020-12-18
CURRENT
AIR5933
AIR5933 provides an overview of contemporary technologies (i.e., sensors) that measure the proportion of oxygen in a gas. The use of these sensors in the aerospace environment, with its special constraints, is discussed and papers/reports with detailed information are summarized and referenced. The sensors are divided into expendable and non-expendable sensors. Expendable sensors are based on electrochemical properties, whereas non-expendable sensors rely on paramagnetic, photo-acoustic, electromagnetic, and laser spectroscopy properties.
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

2014-10-16
CURRENT
AS452B
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
Standard

Oxygen Mask Assembly, Demand and Pressure Breathing, Crew

2003-10-15
HISTORICAL
AS452A
This standard covers both general type and quick-donning type mask assemblies in the following classes: a Class A, oronasal, demand b Class B, oronasal, pressure-demand c Class C, full face, demand d Class D, full face, pressure-demand
Standard

Oxygen Flow Indicators

2016-06-09
HISTORICAL
AS916B
This SAE Aerospace Standard (AS) defines the overall requirements applicable to oxygen flow indicating devices intended to operate in conjunction with an oxygen regulator and mask system. Flow indicators covered by this document are for use with pressure demand, diluter-demand and continuous flow oxygen systems.
Standard

Oxygen Cylinder Quality, Serviceability, Maintenance Transfilling, and Marking

2020-01-17
CURRENT
AIR1059F
This document provides guidance concerning the maintenance and serviceability of oxygen cylinders beginning with the quality of oxygen that is required, supplemental oxygen information, handling and cleaning procedures, transfilling, and marking of serviced oxygen assemblies. This document attempts to outline in a logical sequence oxygen quality, serviceability, and maintenance of oxygen cylinders. Content of this document can also be used for refilling of oxygen cylinder while installed on aircraft, directly or through an intermediate charging port.
Standard

Oxygen Cylinder Quality, Serviceability, Maintenance Transfilling and Marking

2017-05-19
HISTORICAL
AIR1059E
This document provides guidance concerning the maintenance and serviceability of oxygen cylinders beginning with the quality of oxygen that is required, supplemental oxygen information, handling and cleaning procedures, transfilling and marking of serviced oxygen assemblies. This document attempts to outline in a logical sequence oxygen quality, serviceability, and maintenance of oxygen cylinders. Content of this document can also be used for refilling of oxygen cylinder while installed on aircraft, directly or through an intermediate charging port.
X