Refine Your Search

Topic

null

Search Results

Standard

Useful Life Determination for Chemical Oxygen Generators

2013-12-13
ARP1894A
The scope of this document is to provide a guideline for the preparation of a plan for testing of inservice chemical oxygen generators to confirm their design useful life. The test program should also allow determination with a sufficient level of confidence, whether generators are suitable for further use (i.e., life extension, or if the useful life limit has been reached).
Standard

Useful Life Determination for Chemical Oxygen Generators

2014-02-13
ARP1894B
The scope of this document is to provide a guideline for the preparation of a plan for testing of inservice chemical oxygen generators to confirm their design useful life. The test program should also allow determination with a sufficient level of confidence, whether generators are suitable for further use (i.e., life extension, or if the useful life limit has been reached).
Standard

USEFUL LIFE DETERMINATION CHEMICAL OXYGEN GENERATORS

1987-02-01
ARP1894
This document provides recommended guidelines for a comprehensive program to determine the useful life of chemical oxygen generators where useful life is defined as the sum of shelf and service life. Further, this document provides for a test program to determine with a sufficient level of confidence if the generators are suitable for further use and/or if the life limit has been reached. This program should include testing of generators of a representative sampling of a given year's production, of a particular part number, to provide a level of confidence sufficient to permit the units to be used for an additional specified time period.
Standard

Transfilling and Maintenance of Oxygen Cylinders

2008-11-17
AIR1059B
The purpose of this document is to list the best available information and guidelines for the qualification of personnel who are responsible for the filling of fixed or portable aircraft oxygen cylinders.
Standard

TESTING OF OXYGEN EQUIPMENT

1992-08-01
ARP1398
This ARP delineates requirements for system cleanliness, test gas supply system, test stand design, environmental chamber definition, instrumentation, dynamic test equipment and testing procedures.
Standard

STANDARD FOR OXYGEN FLOW INDICATORS

1966-07-01
AS916
This standard is intended to establish general material and design requirements for oxygen flow indicating devices. Flow indicators considered are for diluter-demand and continuous flow systems.
Standard

Reducers, Oxygen Pressure

2023-01-26
AS17852A
This specification covers the requirements for two types of oxygen pressure reducers.
Standard

Reducers, Oxygen Pressure

2009-11-30
AS17852
This specification covers the requirements for two types of oxygen pressure reducers.
Standard

Portable Chemical Oxygen

2011-06-21
AS1303A
This SAE Aerospace Standard (AS) applies to a portable chemical oxygen generator assembly intended for the following uses: a First aid treatment of aircraft occupants after an emergency descent following a decompression or other emergency condition. b Use by cabin attendants to maintain their mobility after a decompression.
Standard

Portable Chemical Oxygen

2017-01-04
AS1303B
This SAE Aerospace Standard (AS) applies to a portable chemical oxygen generator assembly intended for the following uses: a First aid treatment of aircraft occupants after an emergency descent following a decompression or other emergency condition. b Use by cabin attendants to maintain their mobility after a decompression.
Standard

Personal Protective Devices for Toxic and Irritating Atmospheres Air Transport Flight Deck (Sedentary) Crewmembers

2020-09-03
WIP
AS8031B
This SAE Aerospace Standard (AS) covers any protection system that serves the stated purpose. This document establishes minimum performance requirements for emergency equipment, which provides flight deck (sedentary) crewmembers with eye and respiratory protection from toxic atmospheres during in-flight emergencies. Defintion of sedentary: "sedentary" is herein defined as those flight deck crewmembers that remain seated at their flight deck stations throughout the emergency. For those "nonsedentary" cabin crewmembers whose duty it is to leave their flight station during an emergency (for example, to actively locate and fight an on-board fire).
Standard

Packaging and Transportation of Oxygen Equipment

2016-03-05
AIR5742
The scope of this document is related to the particular needs of oxygen equipment with regards to packaging and transportation. The document provides guidance for handling chemical, gaseous and liquid oxygen equipment. It summarizes national and international regulations to be taken into account for transportation on land, sea and air and provides information on classification of hazardous material. The aim of this document is to summarize information on packaging and transportation of oxygen equipment. Statements and references to regulations cited herein are for information only and should not be considered as interpretation of a law. Processes to maintain cleanliness of components and subassemblies during processing and assembly or storage of work-in-progress are outside the scope of this document.
Standard

Oxygen System and Component Cleaning

2018-10-18
ARP1176A
This SAE Aerospace Recommended Practice (ARP) provides recommended practices for cleaning aircraft oxygen equipment such as tubing, pieces, parts (including regulator and valve parts), cylinders and ground-based equipment that may be used to support aircraft oxygen systems. This revision introduces a cleanliness coding scheme that can be referenced as a requirement, and/or referenced to identify compliance to meeting such a requirement. These methods may apply to gaseous and liquid oxygen equipment. This document specifies work area details, methods to select suitable cleaning agents, cleaning methods, test methods to verify cleanliness level, and methods of packaging the components and parts after cleaning. Technicians designated to clean oxygen equipment must be qualified and trained to clean oxygen equipment. This ARP is applicable to metallic and non-metallic parts.
Standard

Oxygen System and Component Cleaning

2020-10-19
ARP1176B
This SAE Aerospace Recommended Practice (ARP) provides recommended practices for the cleaning of aircraft oxygen equipment, both metallic and non-metallic articles, such as oxygen lines (tubes, hoses, etc.), components (including regulator and valve parts), cylinders, and ground-based equipment that may be used to support aircraft oxygen systems. This document also specifies work area details, methods for selecting suitable cleaning agents, cleaning methods, and test methods for verifying levels of cleanliness. The cleanliness coding scheme specified in this document provides a method for documenting minimum cleanliness level requirements and for identifying compliance.
Standard

Oxygen System Maintenance Guide

2023-08-23
AIR1392A
This document is intended to give general instructions and directions for personnel performing maintenance and modification work on Oxygen Systems.
X