Refine Your Search

Topic

Author

Affiliation

Search Results

Viewing 1 to 20 of 13428
Technical Paper

“Fitting Data”: A Case Study on Effective Driver Distraction State Classification

2019-04-02
2019-01-0875
The goal of this project was to investigate how to make driver distraction state classification more efficient by applying selected machine learning techniques to existing datasets. The data set used in this project included both overt driver behavior measures (e.g., lane keeping and headway measures) and indices of internal cognitive processes (e.g., driver situation awareness responses) collected under four distraction conditions, including no-distraction, visual-manual distraction only, cognitive distraction only, and dual distraction conditions. The baseline classification method that we employed was a support vector machine (SVM) to first identify driver states of visual-manual distraction and then to identify any cognitive-related distraction among the visual-manual distraction cases and other non-visual manual distraction cases.
Standard

xEV Labels to Assist First and Second Responders, and Others

2017-03-02
CURRENT
J3108_201703
This recommended practice prescribes clear and consistent labeling methodology for communicating important xEV high voltage safety information. Examples of such information include identifying key high voltage system component locations and high voltage disabling points. These recommendations are based on current industry best practices identified by the responder community. Although this recommended practice is written for xEVs with high voltage systems, these recommendations can be applied to any vehicle type.
Standard

Zinc Phosphate Treatment Paint Base

2019-05-17
CURRENT
AMS2480J
This specification covers the requirements for producing a zinc phosphate coating on ferrous alloys and the properties of the coating.
Technical Paper

Zero Gases for Emission Monitoring - Production, Storage, Treatment and Usage

2002-10-21
2002-01-2712
Increasingly stringent emission levels require better quality facility gas supplies to enable more precise measurements at low levels and reduce variation in test results. The transient and steady state quality of the “zero gas” used in analyzer calibration will directly affect the level of the readings, while variation in the “zero gas” over time will increase the number of tests needed to meet statistical requirements. Facility zero gas supplies for air and nitrogen, at a minimum, require careful evaluation to confirm that the required gas quality is delivered to the test equipment for the desired instrument accuracy. To move from LEV or ULEV to SULEV analysis, a change in methodology of zero gas generation, delivery and handling may be needed to achieve the desired measurement accuracy and repeatability. Traditional tubing, fittings and handling methods can not only limit the possible gas quality, but also contribute to variation.
Standard

Wrenches; Flare Nut, Crowfoot, 6- and 12-Point Non-Distorting

2024-01-22
CURRENT
AS4167D
This SAE Aerospace Standard (AS) covers 6-point and 12-point flare nut crowfoot, flare nut wrenches, double end flare nut wrenches, combination box end and flare nut wrenches, combination open end and flare nut wrenches, and ratcheting flare nut wrenches that are designed with the following requirements: (a) non-distorting usage; (b) possessing the strength, clearances, and internal wrenching design to be used on hydraulic tube fittings that conform to the requirements of SAE J514 and ISO 8434-2; and (c) transmitting torque to tube fittings without bearing on the apex of fitting wrenching points. Inclusion of dimensional data in this document is not intended to imply that all of the products described herein are stock production sizes. Consumers are requested to consult with manufacturers concerning lists of stock production sizes.
X