Standard

VOLTAGE DROP FOR STARTING MOTOR CIRCUITS

1996-10-01
HISTORICAL
J541_199610
The scope of this SAE Recommended Practice is to describe the maximum recommended voltage drop for starting motor circuits for 6 V through 32 V starters.
Standard

Seven-Conductor Cable

1998-06-01
HISTORICAL
J1067_199806
This SAE Standard establishes the minimum construction and performance requirements for seven-conductor 1/8-1/10-5/12 cable for use on trucks and trailers. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Seven Conductor Cable—Truck and Bus

2007-06-12
HISTORICAL
J1067_200706
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-1/10-5/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Seven Conductor Cable for ABS Power—Truck and Bus

2007-06-22
HISTORICAL
J2394_200706
This SAE standard establishes the minimum construction and performance requirements for seven conductor 1/8-2/10-4/12 cable for use on trucks, trailers and converter dollies. Where appropriate, the standard refers to two types of cables, (Type F and S, described later in the standard), due to the variation in the performance demands of cables used in flexing and stationary applications. While the document’s title refers to ABS Power to differentiate the document from the SAE J1067 standard that it supersedes, the scope applies to both the primary green cable for powering ABS and lighting and the yellow auxiliary cable of the same construction.
Standard

SEVEN-CONDUCTOR CABLE FOR ABS POWER

1998-06-01
HISTORICAL
J2394_199806
This SAE Standard establishes the minimum construction and performance requirements for seven-conductor 1/8-2/10-4/12 cable for use on trucks and trailers. Where appropriate, the document refers to two types of cables, (Type F and S, described later in the document), due to the variation in the performance demands of cables used in flexing and stationary applications.
Standard

Recommended Practice for Identification of Standardized Truck and Tractor Electrical Circuits

2023-11-16
CURRENT
J2191_202311
This SAE document defines a recommended practice for implementing circuit identification for electrical power and signal distribution systems of the Class 8 trucks and tractors. This document provides a description of a supplemental circuit identifier that shall be utilized in conjunction with the original equipment manufacturer’s primary circuit identification as used in wire harnesses but does not include electrical or electronic devices which have pigtails. The supplemental circuit identifier is cross-referenced to a specified subsystem of the power and signal distribution system identified in Section 5.
Standard

Recommended Practice for Identification of Standardized Truck and Tractor Electrical Circuits

2019-01-08
HISTORICAL
J2191_201901
This SAE document defines a recommended practice for implementing circuit identification for electrical power and signal distribution systems of the Class 8 trucks and tractors. This document provides a description of a supplemental circuit identifier that shall be utilized in conjunction with the original equipment manufacturer’s primary circuit identification as used in wire harnesses but does not include electrical or electronic devices which have pigtails. The supplemental circuit identifier is cross-referenced to a specified subsystem of the power and signal distribution system identified in Section 5.
Standard

Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design—Truck and Bus

2022-06-22
CURRENT
J2698_202206
This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids.
Standard

Positive Temperature Coefficient Overcurrent Protection Devices (PTCs)

2014-12-03
CURRENT
J2685_201412
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for PTC (positive temperature coefficient of resistance) overcurrent protection devices. PTCs are typically either polymeric (PPTC) or ceramic (CPTC). It is important to note battery voltages versus powernets/system voltage versus max battery voltages: (12 V/14 V/16 V, 24 V/28 V/32 V, and 36 V/42 V/58 V). All voltages are DC. These devices are typically rated with a maximum operating voltage, which for vehicular systems need to be 16 V (for 12 V batteries), 32 V (for 24 V batteries), and 58 V (for 36 V batteries/42 V powernets). PTC devices are considered to be self-resetting after responding to overcurrent conditions and after such condition has been removed from the affected circuit containing the PTC.
Standard

Positive Temperature Coefficient Overcurrent Protection Devices (PTCs)

2006-05-18
HISTORICAL
J2685_200605
This SAE Recommended Practice defines the test conditions, procedures, and performance requirements for PTC (positive temperature coefficient of resistance) overcurrent protection devices. PTCs are typically either polymeric (PPTC) or ceramic (CPTC). It is important to note battery voltages versus powernets/system voltage versus max battery voltages: (12 V/14 V/16 V, 24 V/28 V/32 V, and 36 V/42 V/58 V). All voltages are DC. These devices are typically rated with a maximum operating voltage, which for vehicular systems need to be 16 V (for 12 V batteries), 32 V (for 24 V batteries), and 58 V (for 36 V batteries/42 V powernets). PTC devices are considered to be self-resetting after responding to overcurrent conditions and after such condition has been removed from the affected circuit containing the PTC.
Standard

Identification of Vehicles and Supply Equipment for Conductive AC Charging

2023-12-13
CURRENT
J3068/1_202312
This document is an optional addition to SAE J3068 that adds additional communications (using LIN-CP) between the EV and SE that provide capabilities valuable to commercial fleets. These include the ability of the EV and SE to exchange unique identifiers, to establish which EV is connected to which SE, and to specify requirements for the next trip.
Standard

Combination 11 Conductors and Two Pairs ECBS Cable

2020-02-24
CURRENT
J2742_202002
This SAE standard establishes the minimum construction and performance requirements for a combination cable consisting of 11 conductors and two twisted pairs for use on trucks, trailers, and dollies for 12 VDC nominal applications in conjunction with SAE J2691 (15 pole connectors.) The cable includes both power and unjacketed SAE J1939-15 paired signal circuits along with dual ground wires to accommodate grounding requirements within the constraints of the SAE J2691 terminal capacity.
Standard

Circuit Breakers

2022-05-26
CURRENT
J553_202205
This SAE Standard defines the test conditions, procedures, and performance requirements for circuit breakers in ratings up to and including 200 A. The document includes automatic reset, modified reset, and manually reset types of circuit breakers for 12 VDC, 24 VDC, and 48 VDC electrical systems. Some circuit breakers may have dual voltage ratings (AC and DC); however, this document evaluates DC performance only.