Refine Your Search

Topic

Author

Affiliation

Search Results

Viewing 1 to 20 of 44113
Technical Paper

• Oxidation Stability • Shear Stability • Rubber Swell Properties of Automatic Transmission Fluids

1960-01-01
600048
A NEW TEST is described for studying the oxidation stability of automatic transmission fluids (ATF). The test shows an excellent correlation with transmission oxidation tests and points out the importance of time as a variable in such studies. Carefully controlled automobile dynamometer tests have been used to study the shear stability of ATF's. Data are presented showing a comparison of driving conditions, transmissions, and V.I. improvers on shear stability. Results are related to the 50-hr Hydra-Matic durability test. The poor reproducibility of rubber swell measurements on commercial transmission seals is due largely to differences in the rubber compounds. A great improvement in the reproducibility may be made by taking into account the specific gravity of the rubber sample.*
Technical Paper

“Trapless” Trap – A Catalytic Combustion System of Diesel Particulates Using Ceramic Foam

1983-02-01
830082
“Trapless” Trap, which makes possible the effective collecting of particulates in diesel exhaust gas and their simultaneous combustion has been developed by use of a ceramic foam in combination with catalysts containing copper salt. From a TEM photograph, it was observed that the particulate was rapidly oxidized by mobile copper ion, showing worm-eaten like spots. Screening of various base metal salts by TGA presented CUCl2-KCl-NH4VO3 and CuCl2-KCl-(NH4)6Mo7O24 as very active catalysts for diesel particulate oxidation. They had thermal stability up to 900°C when they were supported on titania. The results obtained by measuring the back pressure using 1.8L diesel engine suggest the above trap to be a self-cleaning trapless trap.
Technical Paper

“Transet” Transmission Controller Development System

1996-08-01
961765
A program was developed that provides a user friendly interface for developing and testing shift tables in a powershift transmission. This program is Windows based and runs on an IBM compatible P.C. When coupled with a suitable controller, transmission designers have a useful tool for the development of transmission shift timing. The system is designed to be used in an engine test cell or for actual vehicle tests. This allows the vehicle operator to call up and edit shifts on a P.C. screen and then drive the vehicle using the new shifts. This allows the operator to evaluate results of real time shifts immediately.
Technical Paper

“The Influence of Idle, Drive Cycle and Accessories on the Fuel Economy of Urban Hybrid Electric Buses - Chassis Dynamometer Tests”

2003-11-10
2003-01-3438
Fuel economy can be part of a business case for a fleet making the decision to buy new HD hybrid drivetrain technologies. Chassis dynamometer tests using SAE Recommended Practice J2711 on a bus equipped with an Allison EP SYSTEM ™ hybrid system and operated on standard bus driving cycles have produced impressive gains of over 60%. Preliminary urban bus field tests, on the other hand, have shown lower fuel economy gains. The difference can be attributed, in part, to the use of accessories - most importantly air conditioning - which are parasitic loads on the vehicle. In this paper the characteristics of driving cycles are studied to determine those factors which have the strongest influence on fuel economy for hybrids. The data show that the number of stopping events in a route or cycle is a strong influence as is the average vehicle speed. Energy analysis will show the relationship of fuel economy benefit and battery energy within a driving cycle.
Technical Paper

“Test Methodology Development for Rig Level Validation of Light Weight Stabilizer Link of EV Bus Suspension”

2024-01-16
2024-26-0357
In the modern and fast growing automotive sector, reliability & durability are two terms of utmost importance along with weight & cost optimization. Therefore it is important to explore new technology which has less weight, low manufacturing cost and better strength. The new technology developed always seek for a quick, cost effective and reliable methodology for its design validation so that any modification can be made by identifying the failures. This paper presents the rig level test methodology to validate and to correlate the CAE derived strain levels, life cycle & failure mode of newly developed light weight stabilizer link for EV Bus suspension
Technical Paper

“Seizure-Delay” Method for Determining the Seizure Protection of EP Lubricants

1939-01-01
390146
IT does not yet seem to be recognized fully that it is the local temperature at the surface of contact and not the local specific pressure that chiefly determines the occurrence of seizure under extreme-pressure-lubrication conditions. This local temperature is the result of the temperature level of the parts lubricated, considered as a whole (“bulk” temperature) and of a superimposed instantaneous temperature rise (temperature “flash”) which is localized in the surface of contact. It appears typical for extreme-pressure-lubrication conditions, as met in gear practice, that the temperature flash is much higher than the bulk temperature. With existing conventional test methods for the determination of the protection against seizure afforded by EP lubricants, a considerable rise of the bulk temperature mostly occurs; as it cannot be controlled sufficiently; thus, leaving an unknown margin for the temperature flash, it renders impossible a reliable determination.
Technical Paper

“SODART” Telescope Silicon Detector Cooling System (Thermal Test Results of the Scale-Down Model)

1992-07-01
921365
The onboard “SODART” telescope silicon detector cooling system of the “Spectrum-X-Gamma” observatory, which is designed for the space objects X-ray radiation study, is described. The scale-down model of the passive cooling system description and thermal vacuum test results of this model are given. In the real cooling system the minimal detector temperature at 300 mW heat release is expected about 107 K.
Technical Paper

“RoHS” Compliant Chrome - Free Conversion Coating for Aerospace Manufacturing

2006-09-12
2006-01-3130
This paper presents, chemistry, test data and processing procedures on a non toxic and environmentally friendly chrome-free conversion coating alternative with the same level of adhesion and secondary corrosion resistance as that found in chrome containing conversion coating systems. Test data from military and independent sources will be presented on secondary coating adhesion, electrical conductivity, filiform and neutral salt-spray corrosion resistance as compared to chromate based systems .on magnesium, aluminum and zinc and their respective alloys. The European “RoSH” initiative will not allow for the presence of any hexavalent chromium on imported electrical components as of July first of 2006. Trivalent chromium based systems generate hexavalent chromium due to the oxidation of the trivalent chromium and as such will not be allowed.
Technical Paper

“Quiet” Aspects of the Pratt & Whitney Aircraft JT15D Turbofan

1973-02-01
730289
This paper describes the engine design details of the Pratt & Whitney JT15D-1 engine as related to noise generation. Design principles and factors contributing to the very low-noise levels on the Cessna Citation aircraft are illustrated. Noise testing experiences and data from static tests on the United Aircraft of Canada Ltd. (UACL) flight test aircraft and from both static and flight tests on the Citation aircraft are discussed. Lessons learned from these tests and some future probabilities are outlined.
Technical Paper

“Phoenix”- A Polyester-Film Inflatable Man-Powered Aircraft

1984-02-01
840028
This paper describes some of the design solutions adopted in solving two major problems besetting man-powered aircraft in use: that of breakage and storage. It describes work leading up to the building and testing of “Phoenix”, a man-powered aircraft with a polyester-film inflatable wing. The paper deals mainly with aspects relating to the wing design and construction.
Technical Paper

“Pedestrian in the Loop”: An Approach Using Augmented Reality

2018-04-03
2018-01-1053
A large number of testing procedures have been developed to ensure vehicle safety in common and extreme driving situations. However, these conventional testing procedures are insufficient for testing autonomous vehicles. They have to handle unexpected scenarios with the same or less risk a human driver would take. Currently, safety related systems are not adequately tested, e.g. in collision avoidance scenarios with pedestrians. Examples are the change of pedestrian behaviour caused by interaction, environmental influences and personal aspects, which cannot be tested in real environments. It is proposed to use augmented reality techniques. This method can be seen as a new (Augmented) Pedestrian in the Loop testing procedure.
Technical Paper

“Optimization” of Lower Deck Cargo Systems

1988-05-01
880973
The ability to carry cargo efficiently in passenger aircraft has influenced airline economics to the point that optimisation of the freight capacity is mandatory. This document discusses the alternative loading possibilities in defined Lover Deck Compartments and their doors to cater for current and future trends in ULD dimensions. As a result items for study centred on: 1) Optimisation of the available volumes Freight capacity resulting in the selection of “Pallets”-doors for both the Forward and AFT Compartments. Flexibility to meet Freight and Baggage requirements. Possible load arrangements to optimize aircraft C of G 2) Bulk Cargo Compartment Additional LD3 Container position in AFT/Bulk compartment to cater for an uneven number of Baggage container, allowing the carriage of an additional pallet. What is regarded as an optimum is presented.
Technical Paper

“MONOGAL”: A New Anti-Corrosion Material for the Automotive Industry

1982-02-01
820335
MONOGAL is a coated steel developped to improve the corrosion resistance of exposed automotive body applications. Its process os based on the brittleness of the η zinc coating in a range of temperatures below the melting point of the zinc. MONOGAL is produced on a hot dip galvanizing line; at the exit of the pot the free zinc is brushed off the light side of the differentially coated sheet. Side 1 of MONOGAL presents a very thin and continuous layer of iron-zinc diffusion alloy with no free zinc. Side 2 is a standard G90 or G60 zinc coating. The iron-zinc alloy layer has excellent anti-galling properties which improve the formability of MONOGAL over two side hot dip galvanized steel with the same r value. MONOGAL also shows good weldability, paintability and corrosion resistance.
Technical Paper

“Hot Tube Test”-Analysis of Lubricant Effect on Diesel Engine Scuffing

1984-02-01
840262
To prevent engine scuffing in the field a new laboratory test called the Hot Tube Test has been established in order to evaluate the high temperature stability of diesel engine oils. In a strip mining application field test using 47 bulldozers powered by the same engine type, half of the engines suffered from piston scuffing failures when operated on a variety of commercially available API CD quality SAE 30 Grade engine oils. All the field test oils have been investigated using the Hot Tube Test, and an analysis of the results indicates that it would be possible to accurately predict scuffing failures by this test method. Furthermore, the reliability of this analysis has been verified by bench engine testing on reference oils. The reasons why the Hot Tube Test predicts the anti-scuffing performance of engine oils are discussed.
Technical Paper

“Herschel-Quincke Spiral” A New Interference Silencer

2003-05-05
2003-01-1722
Over the last ten years there has been a steady growth in the market share of light-duty diesel engines, especially in Europe. At the same time, a general trend in petrol engine development has been seen, in which normal aspirated engines are being replaced by downsized turbocharged engines. Therefore, NVH engineers have to deal with new challenges. Turbochargers produce an aerodynamic noise in the frequency range above 1000Hz, which might influence the exterior and interior noise level. As a result, the additional requirement for acoustical components to reduce this flow noise is going to pose an increasing challenge for air intake system suppliers. This paper describes a new design of well-known wide band silencer first mentioned by A. Selamet, N.S.Dickey and J.M.Novak [1,2]. The silencer works according to the interference principle. The sound is guided into two or more parallel pipes of different lengths.
Technical Paper

“Geometric Dimensioning and Tolerancing”

1968-02-01
680488
Geometric dimensioning and tolerancing is both a “language” and a “technique.” Its objective is to facilitate design, production, and inspection and, simultaneously, provide the most economic results. This paper describes the implementation and practice to accomplish these through illustrating methods to state design requirements specifically and clearly and to provide for maximum producibility, uniformity of interpretation, etc. The need to reflect a common objective for design, production, and inspection via the stated drawing requirement is emphasized. Application and interpretation of geometric characteristics (emphasizing symbology), fundamentals, rules, etc. are presented. Basis for the content of this paper is USASI Y14.5-1966 “Dimensioning and Tolerancing for Engineering Drawings.”
X