Thermodynamics of Incompressible and Compressible Fluid Flow

2019-04-11
CURRENT
AIR1168/1A
The fluid flow treated in this section is isothermal, subsonic, and incompressible. The effects of heat addition, work on the fluid, variation in sonic velocity, and changes in elevation are neglected. An incompressible fluid is one in which a change in pressure causes no resulting change in fluid density. The assumption that liquids are incompressible introduces no appreciable error in calculations, but the assumption that a gas is incompressible introduces an error of a magnitude that is dependent on the fluid velocity and on the loss coefficient of the particular duct section or piece of equipment. Fig. 1A-1 shows the error in pressure drop resulting from assuming that air is incompressible. With reasonably small loss coefficients and the accuracy that is usually required in most calculations, compressible fluids may be treated as incompressible for velocities less than Mach 0.2.
Standard

Thermodynamics of Incompressible and Compressible Fluid Flow

2011-06-20
HISTORICAL
AIR1168/1
The fluid flow treated in this section is isothermal, subsonic, and incompressible. The effects of heat addition, work on the fluid, variation in sonic velocity, and changes in elevation are neglected. An incompressible fluid is one in which a change in pressure causes no resulting change in fluid density. The assumption that liquids are incompressible introduces no appreciable error in calculations, but the assumption that a gas is incompressible introduces an error of a magnitude that is dependent on the fluid velocity and on the loss coefficient of the particular duct section or piece of equipment. Fig. 1A-1 shows the error in pressure drop resulting from assuming that air is incompressible. With reasonably small loss coefficients and the accuracy that is usually required in most calculations, compressible fluids may be treated as incompressible for velocities less than Mach 0.2.
Standard

The Advanced Environmental Control System (AECS) Computer Program for Steady State Analysis and Preliminary System Sizing

2003-10-31
HISTORICAL
AIR1706B
Many different computer programs have been developed to determine performance capabilities of aircraft environmental control systems, and to calculate size and weight tradeoffs during preliminary design. Many of these computer programs are limited in scope to a particular arrangement of components for a specific application. General techniques, providing flexibility to handle varied types of ECS configurations and different requirements (i.e., during conceptual or preliminary design, development, testing, production, and operation) are designated “company proprietary” and are not available for industry-wide use. This document describes capabilities, limitations, and potentials of a particular computer program which provides a general ECS analysis capability, and is available for use in industry. This program, names AECS1, was developed under the sponsorship of the U.S. Air Force Flight Dynamics Laboratory (References 1 and 2).
Standard

THE ADVANCED ENVIRONMENTAL CONTROL SYSTEM (AECS) COMPUTER PROGRAM FOR STEADY STATE ANALYSIS AND PRELIMINARY SYSTEM SIZING

1986-10-01
HISTORICAL
AIR1706A
Many different computer programs have been developed to determine performance capabilities of aircraft environmental control systems, and to calculate size and weight tradeoffs during preliminary design. Many of these computer programs are limited in scope to a particular arrangement of components for a specific application. General techniques, providing flexibility to handle varied types of ECS configurations and different requirements (i.e., during conceptual or preliminary design, development, testing, production, and operation) are designated "company proprietary" and are not available for industry-wide use. This document describes capabilities, limitations, and potentials of a particular computer program which provides a general ECS analysis capability, and is available for use in industry. This program, names AECS1, was developed under the sponsorship of the U.S. Air Force Flight Dynamics Laboratory (References 1 and 2).
Standard

TESTING OF PROTOTYPE AIRPLANE AIR CONDITIONING SYSTEMS

1951-03-15
HISTORICAL
ARP217
These recommendations are written to cover the testing of air conditioning equipment as installed in the prototype aircraft for the purpose of: A Demonstrating safety of the installation. B Demonstrating performance of the installation. a Aircraft ducting and distribution system. b Component parts (i.e., vendors equipment) C Obtaining data for future design.
Standard

TEMPERATURE CONTROL EQUIPMENT, AUTOMATIC, AIRCRAFT COMPARTMENT

1992-03-01
HISTORICAL
ARP89C
The recommendations of this ARP are primarily intended to be applicable to temperature control of compartments, occupied or unoccupied, of civil aircraft whose prime function is the transporting of passengers or cargo. The recommendations will apply, however, to a much broader category of civil and military aircraft where automatic temperature control systems are applicable.
Standard

Spacecraft Life Support Systems

2011-06-20
HISTORICAL
AIR1168/14
A life support system (LSS) is usually defined as a system that provides elements necessary for maintaining human life and health in the state required for performing a prescribed mission. The LSS, depending upon specific design requirements, will provide pressure, temperature, and composition of local atmosphere, food, and water. It may or may not collect, dispose, or reprocess wastes such as carbon dioxide, water vapor, urine, and feces. It can be seen from the preceding definition that LSS requirements may differ widely, depending on the mission specified, such as operation in Earth orbit or lunar mission. In all cases the time of operation is an important design factor. An LSS is sometimes briefly defined as a system providing atmospheric control and water, waste, and thermal management.
Standard

Heat Sinks for Airborne Vehicles

2012-07-12
HISTORICAL
AIR1957
This document summarizes types of heat sinks and considerations in relation to the general requirements of aircraft heat sources, and it provides information to achieve efficient utilization and management of these heat sinks. In this document, a heat sink is defined as a body or substance used for removal of the heat generated by hydrodynamic or thermodynamic processes. This document provides general data about airborne heat sources, heat sinks, and modes of heat transfer. The document also discusses approaches to control the use of heat sinks and techniques for analysis and verification of heat sink management. The heat sinks are for aircraft operating at subsonic and supersonic speeds.
Standard

General Requirements for Application of Vapor Cycle Refrigeration Systems for Aircraft

1997-10-01
HISTORICAL
ARP731B
Recommendations of this ARP refer specifically to the application of closed cycle vapor cycle refrigeration systems as a source of cooling in an aircraft air conditioning system. General recommendations for an air conditioning system which may include a vapor cycle system as a cooling source are included in ARP85, Air Conditioning Equipment, General Requirements for Subsonic Airplanes, ARP292, Air Conditioning, Helicopters, General Requirements For, and AIR806, Air Conditioning Design Information for Cargo and High Density Passenger Transport Airplanes, and are not included herein. Vapor cycle refrigeration system design recommendations are presented in this ARP in the following general areas: a SYSTEM Design Recommendations: (See Section 3) b COMPONENT Design Recommendations: (See Section 4) c Desirable Design Features: (See Section 5)
Standard

GUIDE FOR QUALIFICATION TESTING OF AIRCRAFT AIR VALVES

1982-10-01
HISTORICAL
ARP986A
This document defines tests to be performed on electrically, pneumatically, and mechanically actuated (regulating, modulating, and shutoff) air valves. The valves may be further defined as those which function in response to externally applied forces or in response to variations in upstream and/or downstream duct air conditions to maintain a calibrated duct air condition (i.e., air flow, air pressure, air temperature, air pressure ratio, etc.). The requirements of this document should govern for all qualification tests unless different requirements are established by the detail specifications.
Standard

GUIDE FOR QUALIFICATION TESTING OF AIRCRAFT AIR VALVES

1968-11-01
HISTORICAL
ARP986
This document defines the tests to be performed on electrically, pneumatically, and mechanically actuated (regulating, modulating, and shutoff) air valves. The valves may be further defined as those which function in response to externally applied forces or in response to variations in upstream and/or downstream duct air conditions to maintain a calibrated duct air condition (i. e., air flow, air pressure, air temperature, air pressure ratio, etc. ). The requirements of this document should govern for all qualification tests unless different requirements are established by the detail specifications.
Standard

GENERAL REQUIREMENTS FOR APPLICATION OF VAPOR CYCLE REFRIGERATION SYSTEMS FOR AIRCRAFT

1973-04-15
HISTORICAL
ARP731A
Recommendations of this ARP refer specifically to the application of closed cycle vapor cycle refrigeration systems as a source of cooling in an aircraft air conditioning system. General recommendations for an air conditioning system which may include a vapor cycle system as a cooling source are included in ARP 85, Air Conditioning Equipment, General Requirements for Subsonic Airplanes, ARP 292, Air Conditioning, Helicopters, General Requirements For, and AIR 806, Air Conditioning Design Information for Cargo and High Density Passenger Transport Airplanes, and are not included herein.
Standard

Fault Isolation in Environmental Control Systems of Commercial Transports

2011-06-20
HISTORICAL
AIR1266A
This SAE Aerospace Information Report (AIR) outlines concepts for the design and use of fault isolation equipment that have general application. The specific focus is on fault isolation of environmental control systems (ECS) in commercial transports. Presented are general fault isolation purposes, design principles, and demonstration of compliance criteria. These are followed by three design examples to aid in understanding the design principles. Future trends in built-in-test-equipment (BITE) design are discussed, some of which represent concepts already being implemented on new equipment.
Standard

Fault Isolation in Environmental Control Systems of Commercial Transports

2021-01-12
CURRENT
AIR1266B
This SAE Aerospace Information Report (AIR) outlines concepts for the design and use of fault isolation equipment that have general application. The specific focus is on fault isolation of environmental control systems (ECS) in commercial transports. Presented are general fault isolation purposes, design principles, and demonstration of compliance criteria. These are followed by three design examples to aid in understanding the design principles. Future trends in built-in-test-equipment (BITE) design are discussed, some of which represent concepts already being implemented on new equipment.
Standard

FAULT ISOLATION IN ENVIRONMENTAL CONTROL SYSTEMS OF COMMERCIAL TRANSPORTS

1993-06-01
HISTORICAL
AIR1266
This AIR outlines concepts for the design and use of fault isolation equipment that have general application. However, the specific concern applies only to use with Environmental Control Systems in commercial transports. In particular, automatic Built In Test Equipment (BITE) with manual initiation and software programs are covered as systems already in use.
Standard

Environmental Control for Civil Supersonic Transport

2011-08-10
CURRENT
AIR746C
This document supplements ARP85, to extend its use in the design of ECS for supersonic transports. The ECS provides an environment controlled within specified operational limits of comfort and safety, for humans, animals, and equipment. These limits include pressure, temperature, humidity, conditioned air velocity, ventilation rate, thermal radiation, wall temperature, audible noise, vibration, and composition (ozone, contaminants, etc.) of the environment. The ECS is comprised of equipment, controls, and indicators that supply and distribute conditioned air to the occupied compartments. This system is defined within the ATA 100 specification, Chapter 21. It interfaces with the pneumatic system (Chapter 36 of ATA 100), at the inlet of the air conditioning system shutoff valves.
Standard

Environmental Control for Civil Supersonic Transport

2006-06-28
HISTORICAL
AIR746B
This document supplements ARP85, to extend its use in the design of ECS for supersonic transports. The ECS provides an environment controlled within specified operational limits of comfort and safety, for humans, animals, and equipment. These limits include pressure, temperature, humidity, conditioned air velocity, ventilation rate, thermal radiation, wall temperature, audible noise, vibration, and composition (ozone, contaminants, etc.) of the environment. The ECS is comprised of equipment, controls, and indicators that supply and distribute conditioned air to the occupied compartments. This system is defined within the ATA 100 specification, Chapter 21. It interfaces with the pneumatic system (Chapter 36 of ATA 100), at the inlet of the air conditioning system shutoff valves.