Refine Your Search

Topic

Author

Affiliation

Search Results

Technical Paper

21SIAT-0638 - Fleet Analytics - A Data-Driven and Synergetic Fleet Validation Approach

2021-09-22
2021-26-0499
Current developments in automotive industry such as hybrid powertrains and the continuously increasing demands on emission control systems, are pushing complexity still further. Validation of such systems lead to a huge amount of test cases and hence extreme testing efforts on the road. At the same time the pressure to reduce costs and minimize development time is creating challenging boundaries on development teams. Therefore, it is of utmost importance to utilize testing and validation prototypes in the most efficient way. It is necessary to apply high levels of instrumentation and collect as much data as possible. And a streamlined data pipeline allows the fleet managers to get new insights from the raw data and control the validation vehicles as well as the development team in the most efficient way. In this paper we will demonstrate a data-driven approach for validation testing.
Journal Article

A Metal Fibrous Filter for Diesel Hybrid Vehicles

2011-04-12
2011-01-0604
Trends towards lower vehicle fuel consumption and smaller environmental impact will increase the share of Diesel hybrids and Diesel Range Extended Vehicles (REV). Because of the Diesel engine presence and the ever tightening soot particle emissions, these vehicles will still require soot particle emissions control systems. Ceramic wall-flow monoliths are currently the key players in the Diesel Particulate Filter (DPF) market, offering certain advantages compared to other DPF technologies such as the metal based DPFs. The latter had, in the past, issues with respect to filtration efficiency, available filtration area and, sometimes, their manufacturing cost, the latter factor making them less attractive for most of the conventional Diesel engine powered vehicles. Nevertheless, metal substrate DPFs may find a better position in vehicles like Diesel hybrids and REVs in which high instant power consumption is readily offered enabling electrical filter regeneration.
Technical Paper

A New Device for Transient Measurement of Ultralow Soot Emissions

2004-11-16
2004-01-3267
Future legislation, like EURO IV and EURO V or the US 2007 HD regulation will have massive reduction of particulate emission limits. For this beside improvement of engine combustion also exhaust aftertreatment systems are under investigation, like Diesel Particulate Filters (DPF), or Selective Catalytic Reduction (SCR) of Nitrogen Oxides. For all those tasks transient soot emission monitoring is one of the key features. To meet this demand a new device for the on-line measurement of soot emitted by combustion engines has been developed. Based on the photoacoustic principle, which has been optimized for automotive applications and easy use in test cells, the instrument shows a sensitivity of 5μg/m3, which is lower than current particulate immission standards in ambient air, and a time resolution of 1 sec. In the paper first the principles of measurement are shown, and then the specifications and results from measurements of very low soot concentration in the exhaust gas are presented.
Journal Article

A Novel Singular Perturbation Technique for Model-Based Control of Cold Start Hydrocarbon Emission

2014-04-01
2014-01-1547
High hydrocarbon (HC) emission during a cold start still remains one of the major emission control challenges for spark ignition (SI) engines in spite of about three decades of research in this area. This paper proposes a cold start HC emission control strategy based on a reduced order modeling technique. A novel singular perturbation approximation (SPA) technique, based on the balanced realization principle, is developed for a nonlinear experimentally validated cold start emission model. The SPA reduced model is then utilized in the design of a model-based sliding mode controller (SMC). The controller targets to reduce cumulative tailpipe HC emission using a combination of fuel injection, spark timing, and air throttle / idle speed controls. The results from the designed multi-input multi-output (MIMO) reduced order SMC are compared with those from a full order SMC. The results show the reduced SMC outperforms the full order SMC by reducing both engine-out and tailpipe HC emission.
Technical Paper

A Photoacoustic Sensor System for Time Resolved Quantification of Diesel Soot Emissions

2004-03-08
2004-01-0968
The reduction of particulate emissions limits requires new tools for the tuning of engines and exhaust aftertreatment systems. Time-resolved monitoring of low soot emissions is a key feature for such developments. The paper describes an improved photoacoustic soot sensor, and presents its applications for the characterization of transient exhaust soot emissions before and after Diesel emission after-treatment systems. The detection limit of the unit is around 5 μg/m3 soot, which is two orders of magnitude better than conventional time-resolved transmission measurement. Additionally, a wide dynamic range of four orders of magnitude can be achieved without range switching. The photoacoustic signal is proportional to the soot mass, no significant cross-sensitivities to gaseous absorbers were detected.
Technical Paper

A Review of Diesel Particulate Control Technology and Emissions Effects - 1992 Horning Memorial Award Lecture

1994-03-01
940233
Studies have been conducted at Michigan Technological University (MTU) for over twenty years on methods for characterizing and controlling particulate emissions from heavy-duty diesel engines and the resulting effects on regulated and unregulated emissions. During that time, control technologies have developed in response to more stringent EPA standards for diesel emissions. This paper is a review of: 1) modern emission control technologies, 2) emissions sampling and chemical, physical and biological characterization methods and 3) summary results from recent studies conducted at MTU on heavy-duty diesel engines with a trap and an oxidation catalytic converter (OCC) operated on three different fuels. Control technology developments discussed are particulate traps, catalysts, advances in engine design, the application of exhaust gas recirculation (EGR), and modifications of fuel formulations.
Journal Article

A Sampling and Conditioning Particle System for Solid Particle Measurements Down to 10 nm

2019-09-09
2019-24-0154
The measurement of vehicle particle number emissions and, therefore, regulation, necessitates a rigorous sampling and conditioning technology able to deliver solid emitted particles with minimum particle losses. European legislation follows a solid particle number measurement method with cutoff size at 23 nm proposed by the Particle Measurement Programme (PMP). Accordingly, the raw exhaust is sampled with constant volume, subsequently passes through a volatile particle remover (VPR), and finally is measured with a particle counter. Lowering the 23 nm cutoff size with current VPR technologies introduces measurement uncertainties mainly due to the high particle losses and possible creation of artefacts. This study describes the development and evaluation of a sampling and conditioning particle system, the SCPS, specially designed for sub-23 nm solid particles measurement.
Technical Paper

A Study of the Character and Deposition Rates of Sulfur Species in the EGR Cooling System of a Heavy-Duty Diesel Engine

1999-10-25
1999-01-3566
Various measurement techniques were employed to quantify sulfuric acid deposition levels and concentration of sulfuric acid in the condensate from the recirculated exhaust gas heat exchanger of a 1995 Cummins M11 heavy-duty diesel engine. Methods employed included a modified version of the sulfur species sampling system developed by Kreso et al. (1)*, rinsing the heat exchanger, and experiments employing a condensate collection device (CCD). The modified sampling system was applied to the inlet and outlet of the heat exchanger in order to quantify the changes in various sulfur compounds. Doped sulfur fuel (3300 to 4000 ppm S) was used to increase the concentrations of the various oxides of sulfur (SOx). These tests were performed at mode 9 of the old EPA 13-mode test cycle (1800 RPM, 932N*m) with 17-20% exhaust gas recirculation (EGR) at two EGR outlet temperatures: 160°C and 103°C.
Technical Paper

A Study of the Dilution Effects on Particle Size Measurement from a Heavy-Duty Diesel Engine with EGR

2001-03-05
2001-01-0220
A study of particle size distributions was conducted on a Cummins M11 1995 engine using the Scanning Mobility Particle Sizer (SMPS) instrument in the baseline and downstream of the Catalyzed Particulate Filter (CPF). Measurements were made in the dilution tunnel to investigate the effect of primary dilution ratio and mixture temperature on the nuclei and accumulation mode particle formation. Experiments were conducted at two different engine modes namely Mode 11 (25% load - 311 Nm, 1800 rpm) and Mode 9 (75% load - 932 Nm, 1800 rpm). The nanoparticle formation decreased with increasing dilution ratios for a constant mixture temperature in the baseline as well as downstream of the CPF II for Mode 11 condition. At Mode 9 condition in the baseline, the dilution ratio had a little effect on the nanoparticle formation, since the distribution was not bimodal and was dominated by accumulation mode particles.
Technical Paper

A Study of the Effect of a Catalyzed Particulate Filter on the Emissions from a Heavy-Duty Diesel Engine with EGR

2001-03-05
2001-01-0910
The effects of a catalyzed particulate filter (CPF) and Exhaust Gas Recirculation (EGR) on heavy-duty diesel engine emissions were studied in this research. EGR is used to reduce the NOx emissions but at the same time it can increase total particulate matter (TPM) emissions. CPF is technology available for retrofitting existing vehicles in the field to reduce the TPM emissions. A conventional low sulfur fuel (371 ppm S) was used in all the engine runs. Steady-state loading and regeneration experiments were performed with CPF I to determine its performance with respect to pressure drop and particulate mass characteristics at different engine operating conditions. From the dilution tunnel emission characterization results for CPF II, at Mode 11 condition (25% load - 311 Nm, 1800 rpm), the TPM, HC and vapor phase emissions (XOC) were decreased by 70%, 62% and 62% respectively downstream of the CPF II.
Technical Paper

A Study of the Effects of Exhaust Gas Recirculation on Heavy-Duty Diesel Engine Emissions

1998-05-04
981422
The effects of exhaust gas recirculation (EGR) on heavy-duty diesel emissions were studied at two EPA steady-state operating conditions, old EPA mode 9* (1800 RPM, 75% Load) and old EPA mode 11 (1800 RPM, 25% Load). Data were collected at the baseline, 10% and 16% EGR rates for both EPA modes. The study was conducted using a 1995 Cummins M11-330E heavy-duty diesel engine and compared to the baseline emissions from the Cummins 1988 and 1991 L10 engines. The baseline gas-, vapor- and particle-phase emissions were measured together with the particle size distributions at all modes of operation. The total particulate matter (TPM) and vapor phase (XOC) samples were analyzed for physical, chemical and biological properties. The results showed that newer engines with electronic engine controls and higher injector pressures produce TPM decreases from the 1988 to 1991 to 1995 engines with the solids decreasing more than the soluble organic fraction (SOF) of TPM.
Technical Paper

A Study of the Regeneration Characteristics of Silicon Carbide and Cordierite Diesel Particulate Filters Using a Copper Fuel Additive

1997-02-24
970187
The purpose of this research was to study the pressure drop profiles and regeneration temperature characteristics of Silicon Carbide (SiC) filters with and without a copper-based additive in the fuel, and also to compare their performance with two cordierite traps designated as EX-47 and EX-80. The collection of the particulate matter inside the trap imposes a backpressure on the engine which requires a periodic oxidation or regeneration of the particulate matter. The presence of copper additive in the fuel reduces the particulate ignition temperature from approximately 500 to 375°C. Two SiC systems were tested during this research. The first system consisted of one 14 L SiC trap, while the second system, the dual trap system (DTS), consisted of two 12 L SiC traps mounted in parallel. The test matrix included two types of regeneration tests, controlled and uncontrolled and three levels of Cu fuel additive (0, 30, and 60 ppm).
Technical Paper

A Study of the Regeneration Process in Diesel Particulate Traps Using a Copper Fuel Additive

1996-02-01
960136
The goals of this research are to understand the regeneration process in ceramic (Cordierite) monolith traps using a copper fuel additive and to investigate the various conditions that lead to trap regeneration failure. The copper additive lowers the trap regeneration temperature from approximately 500 °C to 375 °C and decreases the time necessary for regeneration. Because of these characteristics, it is important to understand the effect of the additive on regeneration when excessive particulate matter accumulation occurs in the trap. The effects of particulate mass loading on regeneration temperatures and regeneration time were studied for both the controlled (engine operated at full load rated speed) and uncontrolled (trap regeneration initiated at full load rated speed after which the engine was cut to idle) conditions. The trap peak temperatures were higher for the uncontrolled than the controlled regeneration.
Journal Article

A Study on Operation Fluid Consumption for Heavy Duty Diesel Engine Application using both, EGR and SCR

2013-09-24
2013-01-2474
This paper describes a method for optimization of engine settings in view of best total cost of operation fluids. Under specific legal NOX tailpipe emissions requirements the engine out NOX can be matched to the current achievable SCR NOX conversion efficiency. In view of a heavy duty long haul truck application various specific engine operation modes are defined. A heavy duty diesel engine was calibrated for all operation modes in an engine test cell. The characteristics of engine operation are demonstrated in different transient test cycles. Optimum engine operation mode (EOM) selection strategies between individual engine operation modes are discussed in view of legal test cycles and real world driving cycles which have been derived from on-road tests.
Technical Paper

A Theoretical and Experimental Study of the Regeneration Process in a Silicon Carbide Particulate Trap Using a Copper Fuel Additive

1997-02-24
970188
The purpose of this study was to investigate the pressure drop and regeneration characteristics of a silicon carbide (SiC) wall-flow diesel particulate filter. The performance of a 25 μm mean pore size SiC dual trap system (DTS) consisting of two 12 liter traps connected in parallel in conjunction with a copper (Cu) fuel additive was evaluated. A comparison between the 25 μm DTS and a 15 μm DTS was performed, in order to show the effect of trap material mean pore size on trap loading and regeneration behavior. A 1988 Cummins LTA 10-300 diesel engine was used to evaluate the performance of the 15 and 25 μm DTS. A mathematical model was developed to better understand the thermal and catalytic oxidation of the particulate matter. For all the trap steady-state loading tests, the engine was run at EPA mode 11 for 10 hours. Raw exhaust samples were taken upstream and downstream of the trap system in order to determine the DTS filtration efficiency.
Technical Paper

Accuracy of Particle Number Measurements from Partial Flow Dilution Systems

2011-09-11
2011-24-0207
The measurement of the particle number (PN) concentration of non-volatile particles ≻23 nm was introduced in the light-duty vehicles regulation; the heavy-duty regulation followed. Based on the findings of the Particle Measurement Program (PMP), heavy-duty inter-laboratory exercise, the PN concentration measurement can be conducted either from the full dilution tunnel with constant volume sampling (CVS) or from the partial flow dilution system (PFDS). However, there are no other studies that investigate whether the PN results from the two systems are equivalent. In addition, even the PMP study never investigated the uncertainty that is introduced at the final result from the extraction of a flow by a PN system from the PFDS. In this work we investigate the uncertainty for the three possible cases, i.e., considering a constant extracted flow from the PFDS, sending a signal with 1 Hz frequency to the PFDS, or feeding back the extracted flow to the PFDS.
Technical Paper

Active Limitation of Tire Wear and Emissions for Electrified Vehicles

2021-04-06
2021-01-0328
Eliminating toxic exhaust emissions, amongst them particulate matter (PM), is one of the driving factors behind the increasing use of electrified vehicles. However, it is frequently overseen that PM arise not only from combustion, but from non-exhaust traffic related causes as well; in particular from the vehicle brakes, tires and the road surface. Furthermore, as electrified vehicles weigh more and typically exhibit higher torques at low speeds, their non-exhaust emissions tend to be higher than for comparable conventional vehicles, especially those generated by tires. Fortunately, tire related emissions are directly related to tire wear, so that limiting tire wear can reduce these emissions as well. This can be accomplished by intelligently modulating the vehicle torque profile in real time, to limit the operation in conditions of higher tire wear.
Technical Paper

Advanced Methods for Calibration and Validation of Diesel-ECU Models Using Emission and Fuel Consumption Optimization and Prediction During Dynamic Warm Up Tests (EDC)

2013-01-09
2013-26-0113
A calibration and validation workflow will be presented in this paper, which utilizes common static global models for fuel consumption, NOx and soot. Due to the applicability for warm-up tests, e.g. New European Driving Cycle (NEDC), the models need to predict the temperature influence and will be fitted with measuring data from a conditioned engine test bed. The applied model structure consisting of a number of global data-based sub-models is configured especially for the requirements of multi-injection strategies of common rail systems. Additionally common global models for several constant coolant water temperature levels are generated and the workflow tool supports the combination and segmentation of global nominal map with temperature correction maps for seamless and direct ECU setting.
Technical Paper

Analysis of the Physical Characteristics of Diesel Particulate Matter Using Transmission Electron Microscope Techniques

1979-02-01
790815
An Andersen Impactor was used to collect particulate samples in both the undiluted and diluted exhaust from a Caterpillar 3150 diesel engine operated on the EPA 13-mode cycle. A total of 24 samples were examined using the transmission electron microscope and approximately 300 photomicrographs were taken. The microscope analysis and photomicrographs revealed details concerning the physical characteristics of the particulate and permitted a direct visual comparison of the samples collected. The photomicrographs were used to obtain diameter measurements of the basic individual spherical particles that comprise the much larger aggregates/agglomerates. Nearly 11,000 basic particles were measured and the observed range of diameters was 70-1200 Å. The mean particle diameters in the undiluted and diluted exhaust samples were 479 Å and 436 Å respectively. respectively. A respectively. 436 A respectively.
Technical Paper

Analytical system for combustion engine exhaust emissions

2000-06-12
2000-05-0346
As emission regulations become tighter and tighter, equipment must evolve to be able to achieve the new standards. Also additional test requirements demand a system that is flexible and can accommodate differences both in the tests and the test facility. By that test cell equipment for chassis dynamometer as well as engine dynamometer applications is getting increasingly complex. That also will require new concepts for the design of such systems. In the past emission system design was more likely a collection and packaging process, which has interfaced various independent components. Now, the development of modern analytical emission systems requires a true holistic design process. This paper will describe the demands and the realization of a modern emission system. It can be shown that an extended effort during the design process will result in a high performance system, which still remains simple and robust.
X