Refine Your Search

Search Results

Viewing 1 to 4 of 4
Technical Paper

Effect of Flow Regime in the Horizontal Inlet Header on Refrigerant-Oil Mixture Distribution in a MAC Microchannel Evaporator

2014-04-01
2014-01-0701
The effect of lubricant on distribution is investigated by relating the flow regime in the horizontal inlet header and the corresponding infrared image of the evaporator. Visualization of the flow regime is performed by high-speed camera. R134a is used as the refrigerant with PAG 46 as lubricant, forming foam in all flow regimes. Quantitative information including foam location, foam layer thickness is obtained using a matlab-based video processing program. Oil circulation rate effect on flow regime is analyzed quantitatively.
Technical Paper

Lubricant Effect on Performance of R134a MAC Microchannel Evaporators

2014-04-01
2014-01-0692
This paper presents an experimental study of lubricant effect on the performance of microchannel evaporators in a typical MAC system. R134a is used as the refrigerant with PAG46 lubricant. The increase of oil circulation rate elevates the pressure drop of the evaporator. The specific enthalpy change in evaporator decreases with increasing oil circulation rate, while refrigerant distribution appears to be more uniform as indicated by infrared images of the evaporator surface temperatures. Thus mass flow rate increases.
Technical Paper

Lubricant Impact on R134a Distribution and Microchannel Heat Exchanger Performance

2014-04-01
2014-01-0706
Lubricant in compressor usually flows out with refrigerant. Thus, it is evitable for lubricant to be present in the heat exchanger, which significantly affects the heat exchanger performance. This paper is to investigate the effects of PAG oil on R134a distribution in the microchannel heat exchanger (MCHX) with vertical headers and to provide a tool to model R134a (with oil) distribution and its effects on MCHX capacity. The flow configuration in MCHX under the heat pump mode of the reversible system is mimicked in the experimental facility: refrigerant-oil mixture is fed into the test header from the bottom pass and exits through the top pass. It is found that a small amount of oil (OCR=0.5%) worsen the distribution. But further increasing OCR to 2.5% and 4.7%, the distribution becomes better.
Technical Paper

Visualization and Analysis of Periodic Reverse Flow in an Automobile Microchannel Evaporator

2016-04-05
2016-01-0252
This paper presents the visualization of periodic reverse flow in tubes of an automobile microchannel evaporator. Two microchannel tubes in an off-the-shelf evaporator are modified so that the leading edges are transparent and the rest of the area remains unchanged, providing realistic air heating. Flow visualizations in air heated aluminum tubes and electric heating glass tube are compared and similar flow physics is identified. A mechanistic model of flow reversal is developed. The model is capable of simulating bubble generation, growth coalescence and reverse. The validation against experimental visualization is on the way.
X